background image

2

READ AND FOLLOW ALL INSTRUCTIONS

1.  DANGER: To reduce the risk of injury, do not permit 

children to use this unit unless they are closely supervised 
at all times.

2.  Use this unit only for its intended use as described in this 

manual. Do not use attachments not recommended by 
the manufacturer.

3.  Never drop or insert any object into any opening.

4.  Do not operate this unit without the guard over the suction 

fitting.

5.  The unit must be connected only to a supply circuit that 

is protected by a Ground-Fault Circuit Interrupter (GFCI). 
Such a GFCI should be provided by the installer and 
should be tested on a routine basis. To test the GFCI push 
the test button. The GFCI should interrupt power. Push the 
reset button. The power should be restored. If the GFCI 
fails to operate in this manner, there is a ground current 
flowing indicating the possibility of an electrical shock. 
Do not use this unit. Disconnect the unit and have the 
problem corrected by a qualified service representative 
before using.

6.  A green colored terminal (or a wire connector marked `G’, 

`GR’, `GROUND’, or `GROUNDING’) is provided within 
the terminal compartment. To reduce the risk of electrical 
shock. connect this terminal or connector to the grounding 
terminal of your electrical service or supply panel with a 
continuous green insulated copper wire equivalent in size 
to the circuit conductors supplying the equipment. but no 
smaller than No.10 AWE (5.6mm)

7.  A pressure wire connector on your bath is provided on 

the exterior of the terminal box within this unit to permit 
connection of a No. 8 AWE (8.4mm) solid copper bonding 
conductor between this unit and all electric equipment 
and exposed metal in the vicinity, as needed to comply 
with local requirements.

8.  SAVE THESE INSTRUCTIONS.

ATTENTION

Check tub for concealed damage.

Check color compatibility with other fixtures.

Check to insure that the bath has the proper components.

Access Tubs will not be held responsible for tub

damage or color compatibility problems after whirlpool is installed.

Access Tubs will not be held responsible for cost

of installation or repair if an incorrect tub is installed.

Read instructions before starting installation.

Содержание 3260 Series

Страница 1: ...LLATION OPERATIONAL INSTRUCTIONS 3260 VENETIAN DUAL TOUCH PAD CONTROL Item 1344355 2344355 Manufactured by Access Tubs A Division of Spa World Corp 5701 NW 35th Avenue Miami Florida 33142 America sWalk InTub ...

Страница 2: ......

Страница 3: ...STRUCTIONS Read and follow all instructions and save these instructions WARNING Examine all plumbing for damage and water test before final installation If damage has occurred call our Technical Service Department at 877 249 2388 WARNING Alterations or modifications of the plumbing system without expressed written authorization will invalidate all warranty claims WARNING Installation must comply w...

Страница 4: ... before using 6 A green colored terminal or a wire connector marked G GR GROUND or GROUNDING is provided within the terminal compartment To reduce the risk of electrical shock connect this terminal or connector to the grounding terminal of your electrical service or supply panel with a continuous green insulated copper wire equivalent in size to the circuit conductors supplying the equipment but n...

Страница 5: ...ACCESS TO PUMP AND EQUIPMENT 1 Once the tub is leveled the tub must be supported or stabilized with plaster or mortar If the tub has a supporting base then mortar is not required 2 For Caulking we recommend 100 sanitary silicone rather than latex 3 For quieter operation you may choose to insulate the surrounding PROTECTION OF TUB Use a section of the box cut to size and place in the bottom of the ...

Страница 6: ...u cover tub to avoid use as trash receptacle INSTALLATION CONTINUED PLUMBING ROUGH IN The bath waste opening protrudes below the base approximately one inch You may be required to cut a hole in the subfloor to accommodate bath waste In slab on grade or prestressed concrete floors where cutting is not desired the tub may be raised up by building the platform higher and using extra mortar under the ...

Страница 7: ... LIP OF TUB Note For caulking we highly recommend using 100 silicone rather than a latex silicone because it keeps its elasticity and does not deteriorate FOR A QUIETER WHIRLPOOL WE SUGGEST a Insulate the surround b Set tub in mortar SEALANT TILE GROUT SUB FLOOR FLASHING 1 x4 NOT FOR SUPPORT 1 8 MAKE SURE TUB IS LEVEL TILE GROUT FLASHING 1 8 CLEARANCE MORTAR BASE SUPPORT 1 x4 NOT FOR SUPPORT SEALA...

Страница 8: ... Colors When turned on Chromalight will be in Cycle Mode where the colors will slowly cylce from one to the next To manually select your desired color press the button again and again until the desired color is reached It will stay on this color until turned off ACCESS TOUCH PLUS START UP AND OPERATIONAL INSTRUCTIONS 6 Increase Pressure Decrease Pressure 6 Water Jet Pressure Control Turn control k...

Страница 9: ...er heater does not heat the water beyond the water s original tempurature but drastically the reduces the rate at which the water loses heat CHROMATHERAPY Chromatherapy offers the option to bath in various color wave lengths promoting health and wellness To activate simply press down on the Chromatherapy button Every subsiquent push of the button cycles through the various settings including 9 dif...

Страница 10: ...of purchase and color of your tub CLEANING RECOMMENDATIONS To clean the pipes and pump Fill the tub and pour a cup of bleach or dishwasher soap i e Cascade if bleach is not available run pump for five 5 minutes and let it sit for ten 10 minutes Run the pump for five 5 minutes then rinse two 2 times Wipe off the surface after the rinse because the bleach may discolor some color trimmings After usin...

Страница 11: ...tice of any malfunction or defect must be provided within ten 10 days of the time it is discovered to Access Tubs 5701 NW 35th Avenue Miami Florida 33142 Access Tubs reserves the right to inspect the malfunction or defect on location RESPONSIBILITIES OF OTHERS Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user They...

Страница 12: ...10 NOTES INSTALLER INFORMATION DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE ...

Страница 13: ...11 ...

Страница 14: ...wner s manual with warranty If you have any problems or questions during installation please call technical service at 877 249 2388 Record the numbers here for handy reference Model No Serial No Date of Purchase Manufactured by Access Tubs A Division of Spa World Corp 5701 NW 35th Avenue Miami Florida 33142 Ph 877 249 2388 Fax 866 560 1060 Email info accesstub com 10 1011 America sWalk InTub ...

Отзывы: