Page
12
of
77
Copyright © Access-IS 2020
3.6 Barcode module installation (serial device)
A serial LSR118 communicates directly with the COM port and does not require any additional
drivers to be loaded. Serial connectors are labelled: CONN1 = Barcode , CONN2 = NFC module.
1. Switch off the computer.
2. Connect the serial cables to COM ports on the computer and finger-tighten the two thumbscrews
to secure the connectors to the port.
3. If using a USB power injector cable, plug the injector cable into the coaxial power connector on
the splitter cable and then plug the USB connector into a powered USB port on the computer.
If using an Access-supplied power supply, plug the power cable into the coaxial power
connector on the splitter cable and then connect the external power supply to an AC outlet.
4. Once the device is connected, switch on the computer.
3.7 Barcode module installation (USB device)
Note: If you intend to use the Access driver, ensure that you install the driver before you connect
the LSR118 to the computer.
3.7.1 Driverless keyboard output
There is no additional driver required for this mode. Connect the USB cable from the LSR118 to a
USB port on the computer.
3.7.2 CDC Windows driver
This method of USB installation uses the Windows CDC drivers.
For this method to operate, you must install the CDC drivers using the file,
AccessISUSBCDC.inf
,
http://www.access-is.com/gettingstarted/
The download (USB Driver for CDC Mode) includes full instructions for use.
Windows assigns a virtual COM port to the LSR118 device. You can find out the COM port number
in Device Manager. You will require the port number to configure the LSR118.
3.7.3 Custom HID
3.7.3.1 HID interface using the Access serial driver (Windows only)
The recommended method for using a USB LSR118 is to configure the device to operate in HID
mode. This allows the device to communicate with the Access driver.
For this method to operate, you must install first the Access driver (Access Serial Ports Service
(ASPS)). Download ASPS from
http://www.access-is.com/gettingstarted/
The download (ASPS Software) includes full instructions for use.
Ensure that you install the driver
before
connecting the LSR118 to the host.
3.7.3.2 HID interface without the Access driver
There is no additional driver required for this mode. Connect the USB cable from the LSR118 to a
USB port on the computer.
3.8 NFC module installation (serial device)
A serial LSR118 communicates directly with the COM port and does not require any additional
drivers to be loaded. Serial connectors are labelled: CONN1 = Barcode , CONN2 = NFC module.
Refer to
Barcode module installation (serial device)
on page 12 for installation instructions.