background image

Manual PCI-IDO-48A Series 

 

Warranty

 

 
Prior to shipment, ACCES equipment is thoroughly inspected and tested to applicable specifications. However, 
should equipment failure occur, ACCES assures its customers that prompt service and support will be available. 
All equipment originally manufactured by ACCES which is found to be defective will be repaired or replaced 
subject to the following considerations. 
 

Terms and Conditions

 

If a unit is suspected of failure, contact ACCES' Customer Service department. Be prepared to give the unit 
model number, serial number, and a description of the failure symptom(s). We may suggest some simple tests 
to confirm the failure. We will assign a Return Material Authorization (RMA) number which must appear on the 
outer label of the return package. All units/components should be properly packed for handling and returned 
with freight prepaid to the ACCES designated Service Center, and will be returned to the customer's/user's site 
freight prepaid and invoiced. 
 

Coverage

 

First Three Years: Returned unit/part will be repaired and/or replaced at ACCES option with no charge for labor 
or parts not excluded by warranty. Warranty commences with equipment shipment. 
  
Following Years: Throughout your equipment's lifetime, ACCES stands ready to provide on-site or in-plant 
service at reasonable rates similar to those of other manufacturers in the industry. 
 

Equipment Not Manufactured by ACCES

 

Equipment provided but not manufactured by ACCES is warranted and will be repaired according to the terms 
and conditions of the respective equipment manufacturer's warranty. 
 

General

 

Under this Warranty, liability of ACCES is limited to replacing, repairing or issuing credit (at ACCES discretion) 
for any products which are proved to be defective during the warranty period. In no case is ACCES liable for 
consequential or special damage arriving from use or misuse of our product. The customer is responsible for all 
charges caused by modifications or additions to ACCES equipment not approved in writing by ACCES or, if in 
ACCES opinion the equipment has been subjected to abnormal use. "Abnormal use" for purposes of this 
warranty is defined as any use to which the equipment is exposed other than that use specified or intended as 
evidenced by purchase or sales representation. Other than the above, no other warranty, expressed or implied, 
shall apply to any and all such equipment furnished or sold by ACCES. 
 
 

 
 

Содержание PCI-IDO-48A

Страница 1: ...Diego CA 92121 858 550 9559 FAX 858 550 7322 contactus accesio com www accesio com MODELS PCI IDO 48A PCI IDO 32A and PCI IDO 16A Isolated FET Outputs PCI Card With External Trigger Updates USER MANU...

Страница 2: ...rights of ACCES nor the rights of others IBM PC PC XT and PC AT are registered trademarks of the International Business Machines Corporation Copyright by ACCES I O Products Inc 10623 Roselle Street S...

Страница 3: ...or parts not excluded by warranty Warranty commences with equipment shipment Following Years Throughout your equipment s lifetime ACCES stands ready to provide on site or in plant service at reasonab...

Страница 4: ...ncluded with your board 7 Optional Accessories 8 Chapter 2 Installation 9 Chapter 3 Option Selection 11 Figure 3 1 Option Selection Map 11 Chapter 4 Address Selection 12 Chapter 5 Programming 13 Table...

Страница 5: ...hine Systems Multiple terminal control Office Automation Kiosks Functional Description This series of cards provide 48 32 or 16 opto isolated discrete outputs Each output is individually isolated usin...

Страница 6: ...l if a rising edge of the External Trigger has happened Refer to Chapter 5 Programming for details regarding the functions mentioned above Output connections are via three 50 pin IDC connectors labele...

Страница 7: ...oHS RoHS compliant version Special Order Please contact ACCES with your precise requirement Examples of special orders would be conformal coating custom software etc we will work with you to provide e...

Страница 8: ...hips with standoffs but can also mount on SNAP TRACK or DIN SNAP DIN SNAP 6 Six inch length of SNAP TRACK with two clips for mounting one STB 50 screw terminal board on a DIN rail STB 72CH 50 Pin Thre...

Страница 9: ...following instructions assume the CD ROM drive is drive D Please substitute the appropriate drive letter for your system as necessary DOS 1 Place the CD into your CD ROM drive 2 Type to change the ac...

Страница 10: ...ns from installed ribbon cables to the field equipment wiring 9 Check all connections and installations to ensure the system is ready to be turned on Do not turn on field power before turning on the c...

Страница 11: ...Manual PCI IDO 48A Series 11 Chapter 3 Option Selection There are no user configurable options on this product Figure 3 1 Option Selection Map...

Страница 12: ...mine which resources were assigned In these operating systems you can use either PCIFind or the Device Manager utility from the System Properties Applet of the control panel The card is installed in t...

Страница 13: ...e outputs in Immediate Mode and updated on a rising edge of the External Trigger in External Trigger Mode Refer to Base Address 3 for Immediate and External Trigger Modes Base Address 1 write Port0 Hi...

Страница 14: ...a rising edge of the External Trigger in External Trigger Mode Refer to Base Address 3 for Immediate and External Trigger Modes Base Address 5 write Port2 Low Byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1...

Страница 15: ...ly 11 Bit 3 Return 12 Bit 3 Out 13 Bit 3 Supply 14 Bit 4 Return 15 Bit 4 Out 16 Bit 4 Supply 17 Bit 5 Return 18 Bit 5 Out 19 Bit 5 Supply 20 Bit 6 Return 21 Bit 6 Out 22 Bit 6 Supply 23 Bit 7 Return 2...

Страница 16: ...y 20 Bit 22 Return 21 Bit 22 Out 22 Bit 22 Supply 23 Bit 23 Return 24 Bit 23 Out 25 Bit 23 Supply 26 Bit 24 Return 27 Bit 24 Out 28 Bit 24 Supply 29 Bit 25 Return 30 Bit 25 Out 31 Bit 25 Supply 32 Bit...

Страница 17: ...y 20 Bit 38 Return 21 Bit 38 Out 22 Bit 38 Supply 23 Bit 39 Return 24 Bit 39 Out 25 Bit 39 Supply 26 Bit 40 Return 27 Bit 40 Out 28 Bit 40 Supply 29 Bit 41 Return 30 Bit 41 Out 31 Bit 41 Supply 32 Bit...

Страница 18: ...re connection which is not isolated Configurable to reset outputs on falling edge High 2 0V min Low 0 8V max Note on Isolation Opto Isolators and connectors are rated for at least 500V but isolation v...

Страница 19: ...s manual or just want to give us some feedback please email us at manuals accesio com Please detail any errors you find and include your mailing address so that we can send you any manual updates 1062...

Отзывы: