E1000 Series Safety and Installation Instructions
SI-00101 v2
18
5. Fit the sealing RJ45 connector to the free end of the second Ethernet
cable and connect it to the RJ45 socket on the E10xx as per the
sealing connector
manufacturer’s instructions.
6. Secure the Ethernet cables as necessary so that they do not hang
loose.
7. Finally, connect the PoE+ injector to the AC mains supply.
Check LED indicators
The LED indicators on the front of the E10xx are shown in Figure 15.
Power indicator
When power is first applied, the Power indicator may show a changing
red/green pattern for a couple of seconds and then goes steady green.
If the Power indicator remains off, check the power supply.
Network indicator
The Network indicator shows steady green when there is an Ethernet
connection from the E10xx to another device and there is no activity on
the connection. The indicator flickers when there is activity on the
connection. If the Power indicator is on, but the Network indicator
remains off, check that the data input side of the PoE+ injector is
Figure 15: LED Indicators