E1000 Series Safety and Installation Instructions
SI-00101 v2
15
1. Connect a ground lug (not supplied) to one end of the grounding
conductor (not supplied) as shown in Figure 11.
2. Remove the grounding screw of the E10xx (see Figure 11). Insert
the screw through the grounding lug and screw it back firmly into
the E10xx.
3. Connect the other end of the grounding conductor to earth. If there
is no suitable earth point already in place, use a grounding rod as
shown in Figure 12.
a. Place a grounding rod (not supplied) to allow for the
shortest possible path from the rod to the E10xx.
b. Drive the grounding rod into the ground to a depth of at
least 20 cm below the surface.
c. Attach a grounding clamp (not supplied) to the grounding
rod. You will use this clamp to attach the grounding cable.
d. Attach the grounding conductor to the clamp on the
grounding rod.
e. Secure the grounding cable to a rigid structure using
appropriate fixings at intervals along its length.
Figure 12: Ground connection diagram