MPC-LNK, PC-LNK

Communication Board

(98 C-Bus Standard) / PC-LNK (ISA)

[Characteristics]
MPC-LNK (PC-LNK) is a data network connecting our MPC-68K, NEC PC98 series, and
DOS/V machines.  Unlike networks by other specifications, it does not let the host generate

interruptions or consume system memory.  MPC-LNK itself becomes a RAM board connected
via communication, both the connected 68K and personal computer having shared variables
usable in common.
The connection interface uses RS-485 (750 kpps SDLC standard), where a network can be
easily constructed by a twisted-pair multiple drop (the maximum connection length is 1.2
km according to the RS-485 specification).  MPC-LNK can be utilized not only as a pure
68K network but also as a data exchange network for personal computers using libraries.

Shared variables

These are common variables of 249 bytes which all MPC-LNK can refer to.  Shared variables
are refreshed every 24 sec and can be changed or referred to at real time.  The content set by
the #1 station circulates to the whole every 10 msec, and the content changed by the #2 or
latter station is reflected by the whole every n * 10 msec (n is the number of MPC-LNKs
connected to the network, whose default value is 5).  Also, 68K deals with them as 125 word-
type variables.

Mail forwarding

All the connected MPC-LNKs can perform block transfers by 250-byte units.  In forwarding
mail, the receipt status, forwarding, and read-out by the recipient can be confirmed.

[Specification] Communication

RS-485/SDLC standard 750 kpps.  SN75176B used.

Pulse transformer isolated.

Cable

Shielded twisted pair to be used (60 nF/km)

Bus I/F

MPCLNK: 68K system bus / PC-98 expansion bus standard (full decoding).
PC-LNK: ISA bus.  Installed in the UMB area as memory.

Address

68K: 1000H, 2000H fixed (I/O area).
PC98 / DOS/V: C0000H~ (expanded ROM area 0~BFFH exclusive).

Memory

Shared variables

249 bytes

Send-mail buffer

250 bytes

Receive-mail buffer

250 bytes

Consumed current

150 mA

[Accessories]

(1) Power connectors (H4P-SHF-AA) JST

*2

(2) Contacts (BHF-001T-0.8SS)

JST

*6

LNK-048

Remote IO Unit

24-Point Output / 24-Point Input

[Characteristics]
Remote IO can be used in a MPC-68K system equipped with MPCLNK.  LNK-048 is equipped with 24-
point input and 24-point output, and can monitor the status of a sensor distant from the host or control
the actuator.  Also, if used as an IO etc. for a control BOX of an apparatus, because the host and LNK-
048 can be connected via a twisted pair, it will also become a wiring-saving system.
Also, it can be used as a remote IO of a personal computer equipped with MPCLNK or PCLNK (PCM-
95W03, with a case).

[Specification]

Communication: RS-485/SDLC standard 750 kpps.  SN75176B used.

Pulse transformer isolated.

Cable:  Shielded twisted pair to be used (60 nF/km)
Power source:  DC 24V ± 10%
Consumed current:  150 mA

[Accessories]

(1) Power connector (H4P-SHF-AA)

JST

*1

(2) Power connectors (H3P-SHF-AA)

JST

*2

(3) Contacts (BHF-001T-0.8SS)

JST

*10

* MPC-LNK model will be modified due to production discontinuation of its component ICs within coming years.  Although the new

series and old series cannot be combined, they can be used in the same software environment.  Please take note of this.

(3)

(2)

(1)

(1)

(2)

(1)

(2)

MPCLNK

CEP-028C

CEL CORP.

C

A

Содержание MPC series

Страница 1: ...e 2 MPC 68K Series 16 Bit CPU Controller 4 MPC LNK 8 MPC 816 Series 8 Bit CPU Controller 10 MPC Peripherals Common for MPC 68K and MPC 816 14 How to Deal with Noise 15 FTMW FTM Work Bench 16 List of C...

Страница 2: ...prepared for even an XY orthogonal 4 axis robot that includes palletizing It can also deal with S shape acceleration deceleration Necessary Things for Startup The following are initially necessary to...

Страница 3: ...inside Terminal software FTM FTMW32 Programming teaching personal computer NEC 9801 Toshiba J3100 IBM PC AT compatible machines Windows 95 NT Cable DOS V 98 4 axis robot MPC 68K FSC Main CPU RS 232C...

Страница 4: ...Converter As an option function of MRS 402 WEB FTP and TCP IP are planned to be supported via Ethernet RS converter MBK 68 Display during program execution 7SEG Touch panel support MRS 402 Communicati...

Страница 5: ...us based so an I O board for 98 can also be directly used Specification Powersource DC 12V 24V battery retained for 5 years w o external power supply at roomtemperature CPU TMP68301F 16 16 MHz 1M SRAM...

Страница 6: ...asaTTLoutputinterface AddressescanbespecifiedbyDIPswitches fulldecoding MPC 68K supports up to eight MOP boards Specification Power source DC 5V 24V for I O control 48 point open collector output Cons...

Страница 7: ...xes Accessories 1 Power connector H4P SHF AA JST 1 2 Contacts BHF 001T 0 8SS JST 4 MRS 402 RS 232 Expansion Board RS 232C Characteristics Thisisa2CHRS 232C RS 485 expansionboard ofwhichuptotwocanbeins...

Страница 8: ...ting tool 57031 6000 Molex Contacts 5556TL Molex Housing 5557 04R Molex RACK 68K6 6 Slot Rack RACK 68K3 3 Slot Rack Characteristics These are board racks dedicated to MPC 68K Their design is highly co...

Страница 9: ...t output and can perform reading of input from the host side and control of the output port The host needs one MPCLNK and the I O unit and MPCLNK are connected via a twisted pair cable Because communi...

Страница 10: ...5 SDLC standard 750 kpps SN75176B used Pulse transformer isolated Cable Shielded twisted pair to be used 60 nF km Bus I F MPCLNK 68K system bus PC 98 expansion bus standard full decoding PC LNK ISA bu...

Страница 11: ...tocoupler input 4 axis pulse output port Consumed current 30 mA Accessories 1 Housing PS D4C50 JAE 1 2 Power connector H4P SHF AA JST 1 3 Contacts BHF 001T 0 8SS JST 4 4 Connector HIF 3BA 16D 2 54R Hi...

Страница 12: ...I O can be used by power sources different from the others Also by installing a J2 connector by the user a small scale system can be constructed in combination with MPC 816 without using MIF 816 Speci...

Страница 13: ...point origin returning sensor Maximum pulse rate 50 kpps CW CCW2 pulse method Consumed current 80 mA Accessories 1 Connector HIF 3BA 16D 2 54R Hirose 2 2 Power connector H4P SHF AA JST 1 3 Contacts B...

Страница 14: ...16 board full system The current supply capacity of MPC 816 is up to 380 mA including 816 If a power shortage is anticipated please remove JP1 on MPC 816 and supply DC 5V directly to the bus board MPC...

Страница 15: ...g a sensor containing a two line amplifier can be done easily With a case PCML 95W02 Specification Input 26 pin 50 pin flat cable Output Molex 5557 04R 5556TL Compatible parts Please purchase upon nec...

Страница 16: ...ide of PS NF Motor driving line shielded I O Signal line 24V line MPC Separation Sequencer Stepping motor driver Separation MS Long wiring should be separated by a relay etc Twisted pair cable should...

Страница 17: ...with the latest software and latest functions using the system loader http accelmpc com List of Compatible Connectors 26 Pin I O Connector Hirose Individual wires Housing HIF3BA 26D 2 54C Contacts HIF...

Страница 18: ...photographic strobe and exposure to radiant rays Also there are instances where data are lost due to dew forming during normal transportation and due to vibrations and extreme humidity occurring duri...

Отзывы: