PROGRAMMING SYSTEM OPTIONS
System Options Programming
is a means of setting the
various system options. The U and P options are of the ON / OFF or 1
/ 0 type; the option is either 1 or ON or it is a 0 or OFF. The D options
can only be displayed. They may not be changed by the user. To
initiate options programming press the UP and DOWN arrows
together. There are 3 groups of 8 options each :
User options U1 to U8
Protected options P1 to P8
Diagnostics D1 to D8
When programming groups 1 and 2, (U and P options) either the letter
U or the letter P is displayed followed by a number (1 to 8), a space
and the number 1 if the option was ON or a 0 if the option was OFF.
For example if the third user option was OFF the letters U3 0 will be
displayed. If it was ON the display will read U3 1.
Use the scroll buttons (UP and DOWN) to navigate thru the different
options. Press the SET key to toggle a displayed option's status from
0 to 1 or vice versa. Go to SEND and press SET to save changes.
Alternatively go to CANC and press SET to discard all changes and
restore previous settings.
The Diagnostics are not options, but rather they display internal
values that are indicative of the internal state of the processor. They
are useful for a serviceman or a technician and to pinpoint hardware
problems and error conditions.
The following tables list the User Options and the Protected Options
and their significance when they are ON and OFF.
User Options
U1 0 = Economy mode is on. In this mode water temperature is
sampled every 3 hours or whatever ECL is set to. If the spa
is being used the economy mode is off.
1 = Auto Maintenance is on, temperature is sampled and
acted upon continuously.
Page 17