Shutdown
delay
(s)
When
there
is
the
power
outage
happening,
if
the
power
cannot
be
recovered
within
the
configured
time,
such
as
30
seconds,
the
system
will
auto
shutdown
at
the
moment.
This
function
will
be
disabled
if
the
configured
seconds
is
set
to
“0”.
Shutdown
UPS
The
status
of
shutdown
UPS:
ON:
The
system
will
send
the
command
to
shut
down
the
connected
UPS
if
one
of
the
above
functions
is
triggered
when
the
power
outage
is
happening.
OFF:
Disable
this
function.
Status
The
status
of
UPS:
Detecting…
Running
Unable
to
detect
UPS
Communication
lost
UPS
reboot
in
progress
UPS
shutdown
in
progress
Batteries
failed.
Please
change
them
NOW!
Battery
level
(%)
Current
power
percentage
of
battery
level.
The
system
will
shut
down
either
Shutdown
battery
level
(%)
or
Shutdown
delay
(s)
reaches
the
condition.
User
should
set
these
values
carefully.
Connection
The
Connection
option
provides
the
all
connections
of
file
service
and
iSCSI
service.
In
File
service
tab,
it
displays
the
connection
of
the
file
service.
This
table
shows
the
available
options
and
their
descriptions.
Column
Name
Description
Protocol
The
protocol type of
the
connection.
User
The
connection
user.
Client
The
client
information
of
the
connection.
Server
The
server
information
of
the
connection.
In
iSCSI
service
tab,
it
displays
the
connection
of
the
iSCSI
service.