Action

Operation

Empty Hopper

Press and hold

 Dose

Stop Emptying

Press

 Dose

Back to Preset

Press

 Power

Empty Hopper

To empty the bean hopper, you can press and hold the 

Dose button

. The Orion will continuously 

dispense the beans until you press the 

Dose button

 again to stop. Make sure you place a large 

container on the platform for this operation.

There will be an ‘E’ indicator on the top left corner of the display when emptying the hopper.

In the main display menu, you may use the controls above to choose between presets, enter 

different dosing modes, or start dosing with the current mode.

There are 3 presets in the Orion for storing desired weights. For example, you can set preset 1 at 

18 g for dosing, preset 2 at 20 g, and preset 3 at 35 g. You may adjust the preset value with the 

controls above.

There are 2 different modes in the Orion for operation — Manual dosing mode and Auto dosing 

mode. You may set different modes using the controls above.

Operations

Basic Operations

Set Preset Weight

Switch Mode

6

Action

Operation

Turn On Scale

Press 

Power

 

Turn Off Scale

Double press 

Power

Toggle Presets

Rotate 

Dial

Set Preset Weight

Press 

Power

, rotate 

Dial

, then press 

Power / Dose

Switch Mode

Press and hold 

Power

, rotate 

Dial

, then press 

Power / Dose

Start Dosing

Press 

Dose

Reset Mode

Press 

Power

Empty Hopper

Press and hold 

Dose

Stop Emptying Hopper

Press 

Dose

Action

Operation

Enter Preset Weight 

Setting

Press

 Power

Change Value

Rotate

 Dial

Save Preset Value

Press

 Power / Dose

Action

Operation

Enter Mode Setting

Press and hold 

Power

Switch Mode

Rotate 

Dial

Set Mode

Press

 Power / Dose

Содержание AO101

Страница 1: ...Acaia Orion User Manual AO101 AO102 1 13 37...

Страница 2: ...ng Operations Basic Operations Set Preset Weight Switch Mode Empty Hopper Mode Introduction Mode 1 Manual Dosing Mode Mode 2 Auto Dosing Mode Mode 3 Weighing Mode Settings Accessing the Orion s Settin...

Страница 3: ...and allowing easy access by rotating the dial for different functions Weighing Scale Mode The Orion Bean Doser can function as a smart industrial weighing scale with a capacity of up to 3000 grams Sta...

Страница 4: ...ows CUP rESEt please place a container on the platform 5 When a dose is complete press Power to return to dosing The Orion is designed for dosing portions of beans from 5 grams to a maximum of 3000 gr...

Страница 5: ...aking as it can damage the anodized coating on the product Charging Indicator Rotate 1 While the Orion is in Weighing Mode and the weighing unit is in grams rapidly press the Dose button multiple time...

Страница 6: ...g for dosing preset 2 at 20 g and preset 3 at 35 g You may adjust the preset value with the controls above There are 2 different modes in the Orion for operation Manual dosing mode and Auto dosing mod...

Страница 7: ...veral times to pulse Pulse will slowly add a few more beans if needed 4 Press Power to start a new dose Manual dosing mode can dose on demand with a selected preset A NOISE message will show when a co...

Страница 8: ...Pulse in Auto dosing mode The pulse function also works in the auto dosing mode To pulse or add a few more beans at the end of each dose simply press the Dose button and the Orion will add a small amo...

Страница 9: ...ty To switch to weighing mode rotate the Dial until a W indicator appears on the top left corner of the display The weight of the object on the platform will be shown on the display The Power and Dose...

Страница 10: ...EEP On Off On Default Weighing Unit Unit g oZ g Cup Detection CUP d On Off On Calibration CAL Start calibration About About Show the current Orion Firmware version 1 With Orion powered on press and ho...

Страница 11: ...is recommended in general for the Orion To save your selection and exit the settings sub menu press Dose trAcE will display on the LED to confirm that the selected option has been saved Key Sound Sett...

Страница 12: ...Buttons Button Function Example Power Button Turn On Press to turn on the Orion Turn Off Double press to turn off the Orion Set Save Preset Weight Press to set save preset weight Set Modes Press and h...

Страница 13: ...s under the minimum capacity Error 304 Please calibrate the Doser in a stable environment free of vibration wind etc Error 802 Unable to tare because the weight exceeds the tare range Error 803 Unable...

Страница 14: ...tability 0 1 g Linearity 1d 2d 4d Indication Limit 3090 g 108 99 oz Dosing Error Margin 1 2 beans 0 5 g Input 12 Vdc 1 5 A Battery Li Ion 18650 7 4 V 2600 mAh Battery Life Up to 48 hours Display LED M...

Страница 15: ...l rights reserved No part of the manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means witho...

Отзывы: