Dosing Speed [

 

SPEEd

 

]

You may adjust the dosing speed to prioritize either the accuracy or the speed of dosing. There are 

three speed settings available:

1. PrEC — Precision: Default speed, high accuracy. (default)

2. FASt — Fast: Faster speed, default accuracy (227 grams within 12 seconds); recommended for 

doses of 100 grams or more.

3. GrEEn — Green Bean: Default speed for green beans or light roast beans.

To save your selection and exit the settings sub-menu, press 

Dose

.  

[ SPEEd ] 

will display on the LED 

to confirm that the selected option has been saved.

Zero Tracking Setting [

 trAcE ]

Zero Tracking is a function to help compensate the weight readout fluctuations at zero point to 

improve the usability of the scale. The Acaia Orion is allowed to compensate fluctuations by up to 2d 

according to industrial weighing guidelines. 

1. Off

It is not recommended to turn off Zero Tracking; the zero indication can drift easily as the room 

temperature changes. 

2. 0.5 d~3 d: For example, since each division is 0.1 g, 3 d = 0.3 g. When Zero Tracking is set to be 3 

d, any initial weight b/- 0.3 g on the weighing pan will be zeroed out. 

3. 2 d is recommended in general for the Orion. 

To save your selection and exit the settings sub-menu, press 

Dose

[ trAcE ]

 will display on the LED 

to confirm that the selected option has been saved.

Key Sound Setting [

 bEEP

 

]

1. Set the Key Sound function to Off/On to turn off/turn on the beeping sound.

To save your selection and exit the settings sub-menu, press 

Dose

.  

[ bEEP ] 

will display on the LED 

to confirm that the selected option has been saved.

Default Weighing Unit  [

 Unit ]

1. The Default Weighing Unit is set to grams if [

 9

 ] is selected and ounce if [ 

o2

 ] is selected.

2. Rotate 

Dial 

to switch the Default Weighing Unit between grams and ounces.

To save your selection and exit the settings sub-menu, press

 Dose

.  [ 

Unit 

] will display on the LED to 

confirm that the selected option has been saved.

Cup Detection [ 

CUP.d

 ]

1. The default setting is on.

2. On: Cup detection enabled. Orion will check if there is a container on the weighing platform. If no 

container is detected, Orion will not start dispensing the coffee beans.

3. Off: Cup detection disabled. Orion will start dispensing the coffee beans even if no container is 
detected.

Calibration [

 

CAL

 ]

Please go to 

Page 5: Calibration

  for more information.

About [

 

About

 ]

Shows the current Orion Firmware version.

To update to the latest version, please use Orion Updater on www.acaia.co/pages/apps.

11

Содержание AO101

Страница 1: ...Acaia Orion User Manual AO101 AO102 1 13 37...

Страница 2: ...ng Operations Basic Operations Set Preset Weight Switch Mode Empty Hopper Mode Introduction Mode 1 Manual Dosing Mode Mode 2 Auto Dosing Mode Mode 3 Weighing Mode Settings Accessing the Orion s Settin...

Страница 3: ...and allowing easy access by rotating the dial for different functions Weighing Scale Mode The Orion Bean Doser can function as a smart industrial weighing scale with a capacity of up to 3000 grams Sta...

Страница 4: ...ows CUP rESEt please place a container on the platform 5 When a dose is complete press Power to return to dosing The Orion is designed for dosing portions of beans from 5 grams to a maximum of 3000 gr...

Страница 5: ...aking as it can damage the anodized coating on the product Charging Indicator Rotate 1 While the Orion is in Weighing Mode and the weighing unit is in grams rapidly press the Dose button multiple time...

Страница 6: ...g for dosing preset 2 at 20 g and preset 3 at 35 g You may adjust the preset value with the controls above There are 2 different modes in the Orion for operation Manual dosing mode and Auto dosing mod...

Страница 7: ...veral times to pulse Pulse will slowly add a few more beans if needed 4 Press Power to start a new dose Manual dosing mode can dose on demand with a selected preset A NOISE message will show when a co...

Страница 8: ...Pulse in Auto dosing mode The pulse function also works in the auto dosing mode To pulse or add a few more beans at the end of each dose simply press the Dose button and the Orion will add a small amo...

Страница 9: ...ty To switch to weighing mode rotate the Dial until a W indicator appears on the top left corner of the display The weight of the object on the platform will be shown on the display The Power and Dose...

Страница 10: ...EEP On Off On Default Weighing Unit Unit g oZ g Cup Detection CUP d On Off On Calibration CAL Start calibration About About Show the current Orion Firmware version 1 With Orion powered on press and ho...

Страница 11: ...is recommended in general for the Orion To save your selection and exit the settings sub menu press Dose trAcE will display on the LED to confirm that the selected option has been saved Key Sound Sett...

Страница 12: ...Buttons Button Function Example Power Button Turn On Press to turn on the Orion Turn Off Double press to turn off the Orion Set Save Preset Weight Press to set save preset weight Set Modes Press and h...

Страница 13: ...s under the minimum capacity Error 304 Please calibrate the Doser in a stable environment free of vibration wind etc Error 802 Unable to tare because the weight exceeds the tare range Error 803 Unable...

Страница 14: ...tability 0 1 g Linearity 1d 2d 4d Indication Limit 3090 g 108 99 oz Dosing Error Margin 1 2 beans 0 5 g Input 12 Vdc 1 5 A Battery Li Ion 18650 7 4 V 2600 mAh Battery Life Up to 48 hours Display LED M...

Страница 15: ...l rights reserved No part of the manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means witho...

Отзывы: