background image

24V (RED)

Heat2

Heat1 (WHT)

Fan (GRN)

AC (YLW)

COMMON (BLUE)

24V (RED)

Heat (WHT)

Fan (GRN)

AC (YLW)

COMMON (BLUE)

24V (RED)

Fan (GRN)

AC (YLW)

COMMON (BLUE)

AC2 (YLW)

24V (RED)

Fan (GRN)

AC1 (YLW)

COMMON (BLUE)

WIRING DIAGRAMS

11

INSTRUCTION MANUAL

AC AND TWO HEAT

AC AND ONE HEAT

WIRING DIAGRAMS

10

Climatouch

CT0-7TC-32

TWO AC

ONE AC

Содержание 90064

Страница 1: ...2 YEAR WARRANTY www CLIMATOUCH com INSTRUCTION MANUAL Climatouch CT0 7TC 32 3 Heating and 2 Cooling with Dual Fuel Switch ...

Страница 2: ... TE ER R A AN ND D R RE EC CE EI IV VE ER R K KI IT T Climatouch Part No 90064 Outdoor Wireless Temperature Transmitter and Receiver Kit Includes Transmitter Antenna Receiver Module 2 AA Batteries U S Patent 6 902 117 Accurately Displays Current Outdoor Temperature on the Climatouch Thermostat and Enables Dual Fuel Capability ...

Страница 3: ...LE THERMOSTAT MODE 40 TROUBLESHOOTING 41 IMPORTANT NOTICE 42 WARRANTY 43 Climatouch CT0 7TC 32 Introducing the Climatouch CT0 7TC 32 touch screen thermostat with 3 stage heating 2 stage cooling control and fossil fuel switch available only when combined with Climatouch Outdoor Wireless Transmitter and Receiver Kit Climatouch Part No 90064 7 Day programmable with 4 events per day including fan Larg...

Страница 4: ...eriod of time Cycle rate is often given in units of cycles per hour CPH DIFFERENTIAL Differential is defined as the difference between the cut in and cut out points as measured at the thermostat under specified operating conditions For example if the thermostat turns the heating equipment on at 70 degrees F and turns the heating equipment off at 74 degrees F then the differential is 4 degrees F PR...

Страница 5: ...heating and cooling units should be OFF 2 Separate the backplate from the thermostat by grasping the unit firmly at the bottom lip and pulling gently until the two piece are apart 3 Align the backplate to the wall 4 Mark the three locations for drilling the 3 16 holes required for the plastic screw anchors 5 Remove the backplate and drill the three 3 16 holes in these locations 6 Insert the plasti...

Страница 6: ...UE 24V RED Heat WHT Fan GRN AC YLW COMMON BLUE 24V RED Fan GRN AC YLW COMMON BLUE AC2 YLW 24V RED Fan GRN AC1 YLW COMMON BLUE WIRING DIAGRAMS 11 INSTRUCTION MANUAL AC AND TWO HEAT AC AND ONE HEAT WIRING DIAGRAMS 10 Climatouch CT0 7TC 32 TWO AC ONE AC ...

Страница 7: ...4V RED Reverse Valves ORG Fan GRN HP YLW COMMON BLUE 24V RED 2nd Stage Heat 1st Stage Heat WHT Fan GRN AC YLW COMMON BLUE WIRING DIAGRAMS 13 INSTRUCTION MANUAL ONE HEAT PUMP AND ONE HEAT ONE HEAT PUMP WIRING DIAGRAMS 12 Climatouch CT0 7TC 32 AC AND TWO STAGE FURNACE ...

Страница 8: ...ves ORG Fan GRN HP 1 YLW COMMON BLUE Heat 2 24V RED Reverse Valves ORG Heat 1 WHT Fan GRN HP YLW COMMON BLUE WIRING DIAGRAMS 15 INSTRUCTION MANUAL TWO TRANSFORMER ONE TRANSFORMER WIRING DIAGRAMS 14 Climatouch CT0 7TC 32 TWO HEAT PUMP ONE HEAT PUMP AND TWO HEAT ...

Страница 9: ...l mode button Select the Fan Operation Mode by toggling the fan operation mode button Access MENU SCREEN to enter into all thermostat features and settings Displays Installer Message to review important information CONTROL SCREEN 17 INSTRUCTION MANUAL ToaccesstheCONTROLSCREEN simplytouchtheHOMESCREENScreen anywhere From the CONTROL SCREEN you can Current Room Temperature Current Outdoor Temperatur...

Страница 10: ...CONTROL MODES 19 INSTRUCTION MANUAL Based on your HVAC equipment Climatouch can operate in the following tem perature control modes AUTO or HEAT or EMERGENCY HEAT or COOL or OFF AUTO Climatouch keeps the room tempe ...

Страница 11: ...hen there is a demand for heating or cooling FAN ON The fan runs continuously FAN INTERMITTENT The fan runs 10 minutes per 1 2 hour providing a convenient way to improve air quality and save energy When the fan is running the animated fan icon will appear on the HOME SCREEN 20 Climatouch CT0 7TC 32 FAN OPERATION MODES ...

Страница 12: ... of the HVAC system and should be performed only by a qualified installer 23 INSTRUCTION MANUAL MENU SCREEN 22 Climatouch CT0 7TC 32 To access the MENU SCREEN simply touch MENU from the CONTROL SCREEN From the MENU page you can Access DATE AND TIME SETTINGS to enter the accurate date and time Access PROGRAM SETTINGS to pre program temperature changes during each day of the week Access ENERGY WATCH...

Страница 13: ...d FAN OPERATION MODE by fan operation mode button Enter the event START TIME with Hour Minute and AM PM buttons Choose desired TEMPERATURE SET POINT with and buttons Select the next event and repeat the steps described above Once finished select the next day of the week that you would like to program Climatouch will prompt you to copy the settings Repeat steps to program other days of the week 24 ...

Страница 14: ... normal display at 6 00AM OFF screen background is determined by REVERSE function CONTRAST Toggle the screen contrast settings button 1 10 to select the screen contrast that suits best your thermostat surroundings Climatouch recommends the setting of 7 26 Climatouch CT0 7TC 32 ENERGY WATCH ENERGY WATCH feature provides a report on the energy con sumption and the dollar cost of operating your HVAC ...

Страница 15: ...ort upon your return IMPORTANT HEAT or COOL must be selected from the CONTROL SCREEN before entering the Vacation Settings screen To begin select Vacation Mode ON Select the START Date Select the END Date Adjust the HEAT or COOL temperature setpoint the Vacation mode begins at 10 PM on the day of your departure and ends at Midnight on the day of your arrival When the Vacation mode is active the su...

Страница 16: ...L DAYLIGHT TIME Choose Daylight Time ON or OFF dependent on your Time Zone FILTER Enter the air filter fan run time information here The Filter Monitor feature uses this information to inform you when to change your air filter by displaying CHANGE FILTER icon on the HOME SCREEN ENERGY WATCH Enter the HVAC system consumption parameters rounded off to kW as well as your electrical energy cost kW and...

Страница 17: ...ure in Celsius 5 c to 25 c Temperature in Fahrenheit 13 F to 41 F 1 Available only in combination with WIRELESS OUTDOOR TEMPERATURE TRANSMITTER AND RECEIVER KIT 90064 ADVANCED SETTINGS SYSTEM CONFIGURATION 32 Climatouch CT0 7TC 32 IMPORTANT By inadvertently modifying system configuration settings you may seriously degrade HVAC system performance Choose system heating and cooling equipment remember...

Страница 18: ...1 will function until Stage 2 is activated to help raise or cool temperature if the temperature set point is not reached This unique function avoids excess compressor wear in the case where the necessary temperature set point is not met through setting of the Staging Differential Set to 00 to disable ...

Страница 19: ...7TC 32 ADVANCED SETTINGS HEAT PUMP HP ON when Furnace On Heat Pump and Furnace can operate together when 2nd stage furnace is required HP OFF when Furnace On turns off the Heat Pump when the furnace is On required on some gas or oil furnaces ...

Страница 20: ... 6 F 3 0 C 2 5 5 F 2 5 C 2 0 4 F 2 0 C 1 5 3 F 1 5 C 1 0 2 F 1 0 C 0 5 1 F 5 C ADVANCED SETTINGS CALIBRATION 38 Climatouch CT0 7TC 32 Calibration of Temperature Your Climatouch Thermostat is rated for an accuracy of 1 F 1 C If you have determined due to drafts sunlight or other environmental factors that your thermostat requires calibration follow this easy guide Common cause of offset are lack of...

Страница 21: ... of heating problem between C and Y1 I forgot my PIN and cannot unlock the thermostat Remove the cover plate press the reset button located in the bottom right corner as soon as the message touch to reset password appears touch the screen your PIN will be erased and the thermostat will unlock SIMPLE THERMOSTAT MODE 40 Climatouch CT0 7TC 32 Climatouch can also function as a virtual non programmable...

Страница 22: ...RRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED BY AED Electronics Inc AND ITS SUPPLIERS DISCLAIMER NEITHER AED Electronics Inc NOR ITS SUPPLIERS SHALL BE LIABLE FOR INCIDENTAL CON SEQUENTIAL I...

Страница 23: ...SIRED OPERATION TECHNICAL SUPPORT 1 866 90TOUCH 1 866 908 6824 PHYSICAL DIMENSIONS Case 5 75 x 4 75 x 1 25 145mm x 120mm x 30mm Screen 4 1875 106mm ELECTRICAL RATING 24 volt AC DC Class 2 maximum 4 amps Temperature Accuracy 1 F 0 5 C Humidity Accuracy 5 RH PATENTS 7 156 318 7 145 110 7 050 026 7 028 912 6 902 117 6 786 421 Other Patents Pending AED Electronics Inc 5758 Royalmount Ave Montreal QC H...

Отзывы: