86
TRANSITION TEMPERATURE SETTING
Customizes how the device will ramp
up in levels when triggered ON by
temperature in AUTO MODE. Set a
transition threshold to determine how
much the probe temperature would
need to surpass your trigger point for
the device to increase in level by one.
The higher the transition threshold
figure is set to, the more the probe
temperature would need to surpass your
set temperature trigger for the level to
increase. The lower the figure, the less
the probe temperature would need to
surpass your set temperature trigger for
the level to increase. If the figure is set
to zero, it will jump to your maximum set
level without ramping when triggered ON.
Press the up or down button to cycle
through 0°F to 8°F (0°C to 4°C) and set
a transition threshold. The level will be
set one level above the OFF Mode level
when the sensor temperature first meets
or exceeds the high temperature trigger.
For every transition threshold crossed,
the level will ramp up by one level, up
until it reaches the level set in ON Mode.
In this example, your high temperature
trigger is set at 80°F, the OFF Mode level
is 0, and the ON Mode level is 6. If the
transition threshold is set to 0°F, then the
devices will trigger to run at level 6 when
the sensor temperature meets or exceeds
80°F. However, if the transition threshold
is set to 2°F, then the devices will trigger
to run at level 1 when it meets or exceeds
80°F. It will then step up to level 2 when
meeting or exceeding 82°F, level 3 at
84°F, level 4 at 86°F, and level 5 at 88°F.
From 90°F on, it will run at level 6, the
level set in ON Mode.
Level
CONTROLLER 69
PROGRAMMING
Содержание ADVANCE GROW
Страница 1: ...USER MANUAL ADVANCE GROW SYSTEM COMPLETE INDOOR PLANT KIT...
Страница 2: ......
Страница 12: ...12 CLOUDLAB SERIES ADVANCE GROW TENT...
Страница 25: ...25...
Страница 26: ...26 CLOUDLINE LITE MIXED FLOW INLINE FAN SYSTEMS...
Страница 40: ...40 DUCT CARBON FILTER PREMIUM AUSTRALIAN CHARCOAL...
Страница 51: ...51...
Страница 52: ...52 IONBOARD GROW LIGHT SYSTEM...
Страница 60: ...60 CLOUDRAY CIRCULATION FAN SYSTEM...
Страница 66: ...66 CONTROLLER 69 UIS MULTI DEVICE CONTROLLER...
Страница 99: ......
Страница 100: ...www acinfinity com...