background image

17

FAN EXTENSIONS

S-series fan units connected to the T-series will share the same fan speed and

temperature trigger settings. For example, an AIRFRAME T7 exhaust system 

can control an AIRFRAME S7-N system for intake. If the S-series fan contains

an inline speed controller, please make sure their speed is set on high. 

CONNECTING MORE FANS

Each T-series fan unit includes a port marked

“EXT.” on its backside that enables it to connect

 one S-series fan unit to share the same smart

 controls and power source.

Содержание AC-AFT7-BE

Страница 1: ......

Страница 2: ......

Страница 3: ...lity and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information WELCOME EMAIL support acinfinity com WEB www acinfinity com LOCATION Los Angeles CA 3 ...

Страница 4: ...9137020184 854759004068 854759004549 854759004372 854759004389 PRODUCT AIRFRAME T7 AIRFRAME T7 AIRFRAME T7 N AIRFRAME T7 N AIRFRAME T9 AIRFRAME T9 AIRFRAME T9 N AIRFRAME T9 N MODEL AC AFT7 BE AC AFT7 WE AC AFT7 BN AC AFT7 WN AC AFT9 BE AC AFT9 WE AC AFT9 BN AC AFT9 WN 4 ...

Страница 5: ...et Cooling Guide Key Features Product Contents Installation Filter Maintenance Connecting Additional Fans Controller Programming Other AC Infinity Products Warranty Page 3 Page 5 Page 6 Page 7 Page 8 Page 9 Page 15 Page 17 Page 18 Page 24 Page 25 5 ...

Страница 6: ...nse than colder air will rise on its own It is ideal to position fans near the top of the room configured to exhaust out the warmer air and position fans near the lower part of the room to push in colder air CFM REQUIREMENTS A fan or set of fan s CFM rating measures the rate at which air flows in of a space To obtain the required CFM rating divide the dimensions of a cabinet by 1728 to get the cub...

Страница 7: ... Controller enables temp monitoring thermal control speed control alarms and SMART energy mode DETACHANLE FILTER A high density filter helps remove dust from entering or exiting the room Can be easily detached for cleaning FAN EXPANSION PORTS Each fan unit contains a port to connect an additional fan unit to share the same controls and power source 7 THERMAL PROBE The corded sensor probe construct...

Страница 8: ...PRODUCT CONTENTS T SERIES 8 PLASTIC STENCIL x1 WOOD MOUNTING SCREW SET x4 POWER ADAPTER x1 COOLING FAN UNIT x1 DETACHABLE FILTER x1 May be on Fan Unit THERMAL PROBE x1 ...

Страница 9: ...nt the cooling fan unit onto your door or wall Position the stencils and apply tape to the outer edges STEP 2 Use a pencil to outline the center square and four outer screw holes on the one stencil Check for accuracy before proceeding to the next step 9 ...

Страница 10: ...an and controller use a power drill to create four screw holes Recommended drill bit size around 16 64 STEP 4 Using a saw cut out the center piece as outlined by your markings from step one You may need to first drill a hole at each of the corners to fit your saw through A power jigsaw may be preferred for thicker wood 10 ...

Страница 11: ...tic backside of the fan does not come into contact with the cabinet This is to minimize vibrations which will can cause noise STEP 6 Using the four machine screws secure the fan unit s frame onto the cabinet or wall Push each screw through their corresponding hole located on the frame and wall The included wood screws can also be used instead Tighten the nuts on the other side 11 ...

Страница 12: ...t yet been installed align and insert the filter piece into the docking holes located on the backside of the fan unit STEP 8 Push the filter piece against the back of the fan unit to click it into position Please note that using the detachable filter will reduce air performance of the cooling fan unit 12 ...

Страница 13: ...dapter s connector into the port marked POWER located on the backside of the fan unit 13 STEP 10 Plug the adapter head into a standard outlet or power strip and check to see if the fan s unit screen is on You may need to press the leaf button if the unit was previously set to ECO Mode ...

Страница 14: ...robe Plug the probe s connector into the port marked PROBE located on the backside of the fan unit STEP 12 After plugging in the probe check the fan unit s screen to see that there is now a temperature reading Position the thermal probe near your devices with the highest temperatures ...

Страница 15: ...ts lever to release it from the backside of the fan unit The filter should be cleaned periodically to avoid decreasing the fan s airflow performance STEP 2 Rinse the filter piece with running water or wipe it down with a damp cloth to remove dust and other particles ...

Страница 16: ...filter piece thoroughly with a cloth and leave it out to dry The filter piece should be completely dry before reattaching it to the fan unit STEP 4 Lastly push the filter piece against the back of the fan unit to put it back into position 16 ...

Страница 17: ... T7 exhaust system can control an AIRFRAME S7 N system for intake If the S series fan contains an inline speed controller please make sure their speed is set on high CONNECTING MORE FANS Each T series fan unit includes a port marked EXT on its backside that enables it to connect one S series fan unit to share the same smart controls and power source ...

Страница 18: ...mperature you set the fans to trigger in AUTO and SMART Mode 5 ALARM TEMP Shows the temperature that you set the fan s alarm system to trigger Please see page 21 for more information 6 PROBE TEMP Actively shows the current temperature that the probe is measuring 7 FAN SPEED Shows what speed the fans are currently running at Six speeds are available 8 BUFFER The buffer range settings of AUTO and SM...

Страница 19: ... the fan Whichever speed is designated in this mode will also be the speed used in AUTO Mode and the max speed of the fans in SMART Mode 19 F o F o F o F o SETTING PROBE SPD ALARM SPEED BUFFER F o F o F o F o SETTING PROBE ALARM SPEED BUFFER AUTO AUTO MODE This is the thermostat setting where the fans will start running when the PROBE temperature reaches or surpasses the SETTING temperature The SE...

Страница 20: ...SPEED BUFFER SMART SMART MODE This is the energy saving mode where the fans will change speed depending on the temperature The SETTING temperature can be designated by pressing the up and down triangle buttons while in this mode For every 4 F increment that the PROBE temperature is below the SETTING temperature the speed of the fans will decrease by one level This increment can be changed to 2 F 6...

Страница 21: ...ART Mode so please remember to exit ALARM Mode once the alarm has been set When the alarm is triggered the fans will run at max speed regardless of the setting and will make an audible beep every three seconds This will keep occurring until the temperature drops below the ALARM temp or if any buttons are pressed The alarm can be disabled by pressing the up triangle button until the temperature is ...

Страница 22: ...OCK Holding the MODE button for three or more seconds will lock the controller The controller will still work as programmed however pressing any buttons will not have an effect and will cause the screen lock icon to flash and will make an audible beep three times per second This option was designed to prevent your controller settings from being changed by accident Holding the MODE button again for...

Страница 23: ...n will flash when any buttons are pressed while the controller is locked Please see page 22 for more information ALARM ALERT The alarm alert icon will flash when the probe temperature reaches or exceeds the alarm temperature you have set Please see page 21 for more information on setting up the alarm FAN FAILURE ALERT The fan failure icon will flash when one or more fans in the AIRFRAME cooling sy...

Страница 24: ... in 17 x 13 5 x 1 5 in PRODUCT AIRCOM S6 AIRCOM S7 AIRCOM S8 AIRCOM S9 AIRCOM T8 AIRCOM T9 MODEL AI ACS6 AI ACS7 AI ACS8 AI ACS9 AI ACT8 AI ACT9 RACK SIZE 1U 1U 2U 2U 3U 3U PRODUCT CLOUDPLATE T1 CLOUDPLATE T1 N CLOUDPLATE T7 CLOUDPLATE T7 N CLOUDPLATE T9 CLOUDPLATE T9 N MODEL AI CPT1 AI CPT1 N AI CP2L AI CP2H AI CPT9 AI CPT9 N CLOUDPLATE SERIES The CLOUDPLATE rack fan system is designed for quietl...

Страница 25: ...he warranty program goes into effect on the date of purchase The program will expire two years from the date of purchase If your product becomes defective during that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the product in water incorrect Installation such a...

Страница 26: ... part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without specific permission from AC Infinity Inc ...

Страница 27: ......

Страница 28: ...www acinfinity com ...