Abus wAppLoxx Pro Скачать руководство пользователя страница 8

 

[8] 

wAppLoxx Pro Control Complete Instructions 

 

2. Installing the wAppLoxx Pro Control 

 

 

 

 

 

 

 

 

 

 

 

 

Screw the enclosed external antennas onto 
the connections provided for this purpose and 
mount the housing using four screws. 

 

Make sure there is sufficient spacing (approx. 1 m) to 
the ceiling and walls. 

 

Make sure not to damage the PCB during this 
fitting. 

Mount the housing cover 

Содержание wAppLoxx Pro

Страница 1: ...1 wAppLoxx Pro Control Complete Instructions Installation and operating instructions wAppLoxx Pro Control WLX Pro CTRL...

Страница 2: ...AppLoxx Pro Control 20 5 4 Creating users 21 5 5 Creating user groups 21 5 6 Creating door groups 23 5 7 Locking plan 24 5 8 Activating the web connection 25 6 Advanced configuration 27 6 1 Date and T...

Страница 3: ...3 wAppLoxx Pro Control Complete Instructions 10 5 Remote event 70 11 User interface 72 11 1 Remote functions 73 11 2 Protocol event log 74 12 Conditions of use for wAppLoxx 76...

Страница 4: ...t with the electronics should also be avoided ABUS Security Center GmbH Co KG shall not be held liable for loss or damage caused or alleged to have been caused either directly or indirectly by this ma...

Страница 5: ...ry s specific regulations Information on the wireless range The wireless range between the wAppLoxx Pro Cylinder and the wAppLoxx Pro Control is largely dependent on the individual local conditions pa...

Страница 6: ...second time the notification should no longer appear To ensure a long lifespan and safe operation we recommend using the following high quality batteries wAppLoxx Pro Cylinder Duracell Ultra or Varta...

Страница 7: ...al Exterior dimensions 165 160 28 mm H B T Material White plastic housing Tags max 500 Door systems max 32 per CTRL Pro Configuration Web interface web browser platform independent Functions Optional...

Страница 8: ...trol Screw the enclosed external antennas onto the connections provided for this purpose and mount the housing using four screws Make sure there is sufficient spacing approx 1 m to the ceiling and wal...

Страница 9: ...ework of CE approval we recommend only using the original ABUS power supply unit Item no AZZU10010 AZZU10011 We recommend switching to a new original ABUS power supply unit particularly in the event o...

Страница 10: ...signalling System power consistent green System in update mode or restarting flashing blue Wireless communication between the wAppLoxx Pro Control and wAppLoxx Pro Cylinder blue during wireless commu...

Страница 11: ...ng the wAppLoxx Pro Control directly to a PC laptop 1 Connect the wAppLoxx Pro Control to your PC laptop via a network cable 2 Connect the wAppLoxx Pro Control to the power supply The wAppLoxx Pro Con...

Страница 12: ...Your wAppLoxx Pro Control will now appear under local devices s Recommended configuration We recommend configuring the wAppLoxx Pro Control using the wAppLoxx Pro Control Finder Recommended web brows...

Страница 13: ...ault on delivery User name administrator Password 12345678 Important Please ensure you change the administrator access after initial commissioning Keep the password for administrator access safe Shoul...

Страница 14: ...0 50 In this case first configure your router switch and PC laptop as follows Router Switch IP address 192 168 0 1 Subnet mask 255 255 255 0 PC laptop IP address 192 168 0 2 Subnet mask 255 255 255 0...

Страница 15: ...g the wAppLoxx Control Finder Recommended web browser Use the latest version of Mozilla Firefox or Google Chrome to carry out programming Alternatively Internet Explorer version 11 306 or above or Edg...

Страница 16: ...ory reset is carried out Make sure you secure the data through regular backups Initial start up After logging in for the first time a pop up window will appear asking you to select your language setti...

Страница 17: ...oint you will be asked to do so again each time you log in 5 Quick configuration On the overview page of the main menu you can find an overview of all the important information about your wAppLoxx Pro...

Страница 18: ...pLoxx Pro Cylinder does not have a mechanical reset button the cylinder is set to programming or unpairing mode by presenting the system card The system card can be used for any wAppLoxx Pro Cylinder...

Страница 19: ...6 and 12 seconds for the wAppLoxx Pro Cylinder Arm disarm Check this box to assign permissions for arming disarming the alarm system to the cylinder This function is only available for Intrusion cyli...

Страница 20: ...a tag Programming the reset card 1 You can program the enclosed reset card under the system settings in the System access menu item Click on Program reset card 2 Then present the enclosed reset card t...

Страница 21: ...can describe the respective tag as free text in this field e g the printed number of the medium Web access Assign a user name and password to the user with which they can log in to the user menu via t...

Страница 22: ...u have created one or several schedules you can assign the respective schedule to the user group If you do not use schedules select the field Not used Holiday schedule If you have defined holiday sche...

Страница 23: ...n boxes to assign the respective doors wAppLoxx Pro Cylinders to the door group Certain doors can be found more quickly through the search function Superordinate group The respective door group can be...

Страница 24: ...relevant checkbox The following selection options appear when you click on one of the checkboxes Grant general permission Access authorisation is granted for the selected door group and its subordina...

Страница 25: ...the door group only have access authorisation for the Office 1 door 5 8 Activating the web connection Activating the web connection for the wAppLoxx Pro app The wAppLoxx Pro Control must be connected...

Страница 26: ...s the successful activation 6 You can now connect to your wAppLoxx Pro Control via the wAppLoxx app Use the QR code scan function on your app under menu item Add manually The QR code can be scanned vi...

Страница 27: ...plete Instructions 6 Advanced configuration It is essential to configure the date and time to ensure the device functions correctly Please ensure you change the administrator access after initial comm...

Страница 28: ...ny we recommend the NTP server ptbtime1 ptb de Update Interval Select an interval in which the time is synchronised via the NTP Server The wAppLoxx Pro Control must have access to the internet for thi...

Страница 29: ...ng Log view settings Selecting the two man rule means the event log can only be accessed when a second user is registered in the log menu The two man rule only functions with access via the website It...

Страница 30: ...nder Sender name for the wAppLoxx Pro Control Sender email address The email address associated with the sender SMTP server SMTP server address of the provider Port Enter the SMTP port standard port 2...

Страница 31: ...ter If no DHCP function is available you can enter the connection data manually Contact your network administrator for assistance if necessary IP address IP address of the wAppLoxx Pro Control IPv6 mo...

Страница 32: ...ther you would also like to enable the HTTP protocol For security reasons we recommend only authorising access via the HTTPS port This ensures that only secured connections can be established and the...

Страница 33: ...pdate and restarts the wAppLoxx Pro Control The wAppLoxx Pro Control must not be disconnected from the power supply during the update process To restart the wAppLoxx Pro Control select the Restart but...

Страница 34: ...em to another wAppLoxx Pro Control you can export them to a configuration file conf This file contains all settings with the exception of the wAppLoxx Cylinder These must be registered again from scra...

Страница 35: ...the master and slave control are required for smooth operation 1 Connect both wAppLoxx Pro Controls to your network establish the power supply and connect to both controls using the wAppLoxx Pro Find...

Страница 36: ...Pro Control as a master and add a slave control tick the Activate Master Only checkbox in the System settings System access menu item 8 Now tick the IP1 checkbox and enter the IP address of the slave...

Страница 37: ...ppLoxx Pro Controls has been successful this will be displayed at the bottom screen edge If you then log in to a slave control as an administrator you will be able to see the slave status of the wAppL...

Страница 38: ...this slave control are programmed and managed The rights and user management is carried out via the master control Now the desired wAppLoxx Pro Cylinder can be programmed in the slave control The info...

Страница 39: ...can also be performed in any order and changed at any time We recommend the following approach for the initial commissioning process 1 Create doors create wAppLoxx Cylinder 2 Program the reset card 3...

Страница 40: ...Pro Control Complete Instructions All wAppLoxx Pro Cylinders that have been created are displayed in the door overview with their signal strength and battery status This also includes Edit Lock and De...

Страница 41: ...one select No to continue counting the openings cycles Making the wrong selection here can mean that the cylinder does not give a battery warning at the right time and that it will no longer be possib...

Страница 42: ...er is set to programming or unpairing mode by presenting the system card The system card can be used for any wAppLoxx Pro Cylinder Reset card In order to prevent unauthorised unpairing of the cylinder...

Страница 43: ...this function in the selection field Only one wAppLoxx can be defined as a reader for each wAppLoxx Pro Control Programming To program a wAppLoxx in the wAppLoxx Pro Control click on the Program butto...

Страница 44: ...ting schedules see Chapter 9 It should however be noted that permanent access cannot be activated for an Intrusion cylinder that is armed This must first be disarmed by an authorised person 8 2 Schedu...

Страница 45: ...of schedules To select access times select the appropriate bars using the mouse PC or your finger tablet smartphone One bar represents 15 minutes Example The bar above 6 represents the period from 06...

Страница 46: ...holiday schedules to the respective general schedules The holiday access times that have been set in the schedules are applicable on the selected holiday days 8 4 User groups Individual users are gro...

Страница 47: ...ere you have the option to select a schedule for the access group Holiday Here you have the option of checking this box to activate the holiday function for this user group 8 5 Users and tags Creating...

Страница 48: ...ewing the door protocols This is achieved by clicking on Enable event log Users must log into their own user interface see Chapter 14 to execute these functions Users must enter a user name and passwo...

Страница 49: ...d to have been configured see Chapter 13 1 Enable arm disarm Users are authorised to arm and disarm the door systems for the selected access group Arm only Users are only authorised to arm the door sy...

Страница 50: ...fallback tags with each wAppLoxx Cylinder If do you not wish to have a fallback function for one or several cylinders these must be declared as exceptions When you select the fallback authorisation al...

Страница 51: ...hom the tag is assigned Export To export the user list click on the Export button The file is exported in CSV format Select the UTF 8 format when opening the CSV file to ensure it displays correctly 1...

Страница 52: ...oxx Pro Control Complete Instructions In the text import wizard select file origin Unicode UTF 8 and make sure that Delimited is selected Then click Next 4 Select Tab and Comma as delimiters and click...

Страница 53: ...53 wAppLoxx Pro Control Complete Instructions Now select the data format General and click on Finish...

Страница 54: ...ers e g in the event of a recovery of the wAppLoxx Pro Control system For a successful user import the data and column names must be created as a csv file as shown in the example Restoring the setting...

Страница 55: ...ngle permission Access authorisation is granted for the selected door group Remove permission Access authorisation is removed from the selected door group and its subordinate groups Example see above...

Страница 56: ...t to enter the local connection data of the desired camera in order to access the camera even externally via the app A connection to the ABUS server is no longer absolutely necessary If you are using...

Страница 57: ...57 wAppLoxx Pro Control Complete Instructions 10 Events...

Страница 58: ...lay types required by the alarm panel you have connected Open latched Relay closed when armed Closed latched Relay open when armed Open timed Relay closes for one second when armed Closed timed Relay...

Страница 59: ...status the wAppLoxx Pro Control is also switched between armed and disarmed accordingly This ensures that the connected alarm panel and the wAppLoxx Pro Control have the same status Input 2 is used by...

Страница 60: ...layed If this option is checked then this input is active Connection to the alarm panel There are four options available for connecting the wAppLoxx Pro Control to an alarm panel 1 Alarm system fully...

Страница 61: ...and Arm Output options are connected to the alarm panel This makes it possible to arm and disarm the system using the wAppLoxx Pro Control however there is no forced action requested via the alarm pa...

Страница 62: ...system is unarmed 4 No alarm panel locking function via wAppLoxx Pro Control Only the Arm Output of the wAppLoxx Pro Control is configured although it is not connected This makes it possible to lock...

Страница 63: ...63 wAppLoxx Pro Control Complete Instructions Configuration of the wAppLoxx Pro Control to the Secvest alarm panel interface...

Страница 64: ...pLoxx Pro Control Complete Instructions Configuration of the wAppLoxx Pro Control to the Secvest alarm panel interface tamper contact Configuration of the wAppLoxx Control for monitoring cover back ta...

Страница 65: ...65 wAppLoxx Pro Control Complete Instructions Configuration of the zone type on the Secvest Configuration of wired zone 301 as key switch duration on the Secvest...

Страница 66: ...tructions Configuration of wired zone 302 as a tamper zone on the Secvest Configuration of the wired output 301 relay 01 for the ready signal on the Secvest Configuration of the wired output 302 relay...

Страница 67: ...Complete Instructions 10 3 Creating events To create an event select Events in the main menu then click on Create Event An event always comprises an action and a reaction Enter a name for the event a...

Страница 68: ...d at a selected door Only the tags that function with the set mode are recorded Tamper Action starts as soon as the tamper contact is interrupted Battery warning Action starts as soon as the selected...

Страница 69: ...after an action a relay is to be triggered as a reaction select relay output 2 relay connection 2 see Chapter 3 Type Choose between the various relay types Open timed Relay closes for a set period wh...

Страница 70: ...ox to activate monitoring of the cover tamper switch Back tamper Check this box to activate monitoring of the back tamper switch As soon as monitoring is activated the Tamper event type can trigger an...

Страница 71: ...te Event should be triggered Status Indicates whether the condition for releasing the cylinder has been met Locking function cylinder locking controlled via external activation The locking function en...

Страница 72: ...s the user level please enter the user data User data is created in the administrator user menu Chapter 11 Users We recommend that users change their password after starting up for the first time When...

Страница 73: ...e remote control function of the wAppLoxx Pro Cylinder for 30 seconds Pressing it again stops the function immediately After activating the remote opening function the outer knob on the wAppLoxx Cylin...

Страница 74: ...col event log To protect sensitive personal data the wAppLoxx Pro Control can be configured so that the event log is only displayed after a second authorised user logs in The four eyes principle can b...

Страница 75: ...Access denied Four eyes principle Remote opening Login failed Unknown tag System start Armed System reboot Disarmed Reset to factory default Battery warning External input Supervision loss Tamper Enab...

Страница 76: ...may only be used after the user has agreed to the conditions of use according to Article 7 of the GDPR The user hereby agrees to provide the following data to the wAppLoxx online service which is requ...

Страница 77: ...f your personal data Please contact us at datenschutz abus de You are required to connect your wAppLoxx product to our online services in order to access the full range of functions In the event of a...

Страница 78: ...of with domestic waste At the end of its lifespan dispose of the product according to the applicable legal requirements Please contact your dealer or dispose of the products at the local collection po...

Страница 79: ...79 wAppLoxx Pro Control Complete Instructions ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing Germany...