19
English
5. Description of the DIP switches and status LEDs
5.1 DIP switches
Number
Function
ON position
OFF position
1
Master (CPE) / Slave (CO)
Control unit (Master)
End device (Slave)
2
Transmission
Fast mode
Interleave mode
3 Transmission
rate
Unlimited
Limited
4
Signal-to-noise-ratio
6 dB
9 dB
DIP 1: Master / Slave
ON position
Control device
Use this switch position to connect the device to a PC or a
router which accesses the network camera on the slave side.
OFF position
End device
Select this switch position to use the device on the network
camera.
DIP 2: Transmission
ON position
Fast mode
Use this setting to establish a fast data connection. Please
observe that data loss could occur using this setting.
OFF position
Interleave mode
Use this setting if there is a high data rate, and thereby avoid
any data loss on the transmission range.
DIP 3: Transmission rate
ON position
Unlimited
Use this setting to utilise a maximum data connection with a
transmission rate of up to 100 MB/s download/60 MB/s upload.
OFF position
Limited
Use this setting in the event that data losses occur on the
transmission line. The transmission rate is then decreased to
50 MB/s download / 30 MB/s upload in order to reduce the
data loss.
DIP 4: Signal-to-noise-ratio (SNR)
ON position
6 dB
Standard noise reduction which is used to compensate
interference on the line.
OFF position
9 dB
Increased noise reduction; the signal-to-noise ratio is
increased in this mode. This will be necessary in the event that
increased data loss occurs on the wiring section. The
maximum transmission path is then reduced in this mode.