5.  Advanced Z-Wave Parameters 

 

5.1.  Association Group Information 

Z-Wave devices  can control other devices  directly.  This direct  control is called in  Z-
Wave association. For this purpose, the device ID of the device to be controlled must 
be stored in the controlling devices. This is done in so-called association groups. An 
association group is always linked to an event in the controlling device (pressing a key 
or triggering a sensor). When this event occurs, a control command - usually a BASIC 
SET - is sent to all devices stored in an association group. 

 

The siren supports the following association group: 

 

Group 
Number

 

Maximum 
Devices

 

Transmitted Content

 

Group 1 

0x05 

Association  group  1:  Lifeline  association  group  Include 
command classes: Switch Binary report ,Battery and Device 
Reset Locally notification. 

 

5.2.  Supported Command Classes 

Z-Wave plus InfoVersion 2  

Switch Binary Version 1  

Association Version 2   

Association Group Info Version 1  

Transport Service Version 2  

Version Version 3  

Manufacturer Specific Version 2  

Device Reset Locally Version 1  

Powerlevel Version 1  

10 

Security 2 Version 1   

11 

Supervision Version 1  

12 

Basic Version2 

 

 

 

 

 

 

 

 

 

 

Содержание SHSG10000

Страница 1: ...0000 ABUS Z Wave Siren Important information and FAQs about this product and other products can be found on the website www abus com Version 1 0 Original operating instructions in English Keep for fut...

Страница 2: ...ormation on battery disposal 5 2 7 Cleaning 5 2 8 Information on device disposal 5 2 9 Power Supply 6 3 Product introduction 6 3 1 Scope of delivery 6 3 2 Device features 6 3 3 Operating Principle 7 3...

Страница 3: ...found at www abus com product SHSG10000 It can also be obtained at the following adress ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing GERMANY 1 2 Disclaimer of Liability These operat...

Страница 4: ...gnetic fields e g loudspeakers no naked flames e g lit candles are placed on or next to the device sprayed or dripping water is prevented from coming into contact with interior devices and caustic flu...

Страница 5: ...the restrictions set by the EU Directive 2006 66 EG If batteries are not disposed of properly these substances can cause harm to human health or the environment 2 7 Cleaning Dusty devices must be cle...

Страница 6: ...e or installation work The device is only fully disconnected from the mains network when the device is removed In order to eliminate the risk of fire the device s mains plug should always be disconnec...

Страница 7: ...nutes or operate in standby mode for approx 4 hours even when removed from the power supply 3 4 Performance features The ABUS Z Wave SHSG10000 is an radio siren with integrated backup battery is Z Wav...

Страница 8: ...on 3 times within 1 5 seconds and the Status LED will flash 3 times If the Add device process is successful the Status LED will turn off Repeat the inclusion process from step B if it was not successf...

Страница 9: ...d only be used if the primary gateway is not capable of acting 2 If the multi sensor is set to the factory setting the status is set to not included the association settings and possible configuration...

Страница 10: ...nd usually a BASIC SET is sent to all devices stored in an association group The siren supports the following association group Group Number Maximum Devices Transmitted Content Group 1 0x05 Associatio...

Страница 11: ...240 V AC Backup Battery 3 8 V 700 mAh Lithium Power consumption standby mA 15 Power consumption alarm mA 19 Battery life 4 hours or 5 minutes in case of emergency Alarm volume dB 95 1m Range open fie...

Отзывы: