1.  Introduction 

 

Dear customer, 
We are pleased that you have chosen our product and thank you for your trust! You 
made a good choice. 
This Magnetic contact (hereinafter referred to as the "device") has been developed and 
manufactured  with  the  utmost  care.  Please  read  these  operating  instructions 
completely and observe all operating and safety instructions, as this ensures the best 
possible  handling  of  the  device.  This  document  is  an  installation  and  maintenance 
manual. 
 
All contained company names and product designations are trademarks of the 
respective owners. All rights reserved. 
If you have any questions, please contact your specialist installer or specialist trade 
partner! 
 

1.1.  Declaration of Conformity 

ABUS Security-Center hereby declares that the enclosed product comply with 
the requirements of the following directives 

 

RED  Directive  (2014/53/EU),  EMC  Directive  (2014/30/EU),  Low  Voltage  Directive 
(2014/35/EU)  and  RoHS  Directive  (2011/65/EU).  The  full  EU  Declaration  of 
Conformity text can be found at:  

 

www.abus.com/product/SHRM10000

 

 

It can also be obtained at the following adress: 

ABUS Security-Center GmbH & Co. KG, 

Linker Kreuthweg 5, 86444 Affing, GERMANY 

 

1.2. 

Declaration of Service 

This smoke detector has been tested and certified as a construction product in 
accordance with EU 305/2011. Production is monitored by regular and independent 
controls to ensure that legal and normative requirements are maintained. 
You can find the declaration of performance 

SHRM10000#2018

 under 

www.abus.com/ger/Service/Leistungserklaerungen 

 

 

1.3. 

Disclaimer of Liability 

These operating instructions have been prepared with the greatest care. Should you 
nevertheless notice omissions or inaccuracies, please inform us in writing at the above 
address. 

Your rights are limited to the repair or replacement of this product as delivered. ABUS 
Security  Center  assumes  no  liability  for  any  special,  incidental  or  consequential 
damages, including but not limited to loss of revenue, loss of profit, restrictions in the 
use  of  the  software,  loss  or  recovery  of  data,  costs  for  replacement  equipment, 
downtime, property damage and claims of third parties, as a result of and in connection 

Содержание SHRM10000

Страница 1: ...ABUS Z Wave Smoke detector Important information and FAQs about this product and other products can be found on the website www abus com Version 1 0 Original operating instructions in English Keep for...

Страница 2: ...3 3 Funktionsprinzip 7 3 4 Performance Features 7 3 5 Use in systems of different manufacturers 7 4 Selecting location 7 4 1 Special installation cases 8 Where smoke alarm devices should not be insta...

Страница 3: ...formity text can be found at www abus com product SHRM10000 It can also be obtained at the following adress ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing GERMANY 1 2 Declaration of S...

Страница 4: ...idity e g bathrooms or excessive accumulation of dust Please refer to the individual devices technical data for more detailed information Ensure that adequate ventilation is always guaranteed no direc...

Страница 5: ...sed batteries must not be disposed of along with household waste in accordance with the battery directive To protect natural resources and promote the recycling of materials separate the batteries fro...

Страница 6: ...symbol means that in the interest of environmental protection the device must be disposed of separately from household or industrial waste at the end of its service life in accordance with applicable...

Страница 7: ...cenes smart functions can also be initiated in addition to the alarm e g smoke detector triggers front door unlocks for emergency services 3 4 Performance Features The ABUS Z Wave SHRM10000 is a batte...

Страница 8: ...s in this manual and the detailed information available in the EN14676 standard Smoke alarm devices for use in residential buildings apartments and rooms with similar purposes Installation use and mai...

Страница 9: ...oped at an angle of 20 detectors should be installed 0 5 1 m away from the highest point Partially sloped ceilings The instructions for fully sloped ceilings apply for partially sloped ceilings with a...

Страница 10: ...ithout fail A regular test is also recommended Keep the device at arm s length to protect your hearing To carry out a test press the Test button shortly 4 4 Weak batteries If the detector s battery ch...

Страница 11: ...ustic alarm can be deactivated for 10 minutes by pressing the Test button If the muting function is active the red LED flashes every 10 seconds If smoke is still detected in the smoke measurement cham...

Страница 12: ...ate to the ceiling with the screws recommended Alternative Loosen the cover of the double sided adhesive and glue the mounting plate to the ceiling Note When marking the drill holes make sure that the...

Страница 13: ...the smoke alarm device is functioning properly 5 3 Exclusion Remove device A Click the Remove button in your Z Wave App and follow the further instructions B Press the Network button 3 times within 1...

Страница 14: ...3 Test the smoke alarm device To do so press and release the test button The alarm will sound loud short beeps indicating that the smoke detector works normally Turn the detector back onto the bracket...

Страница 15: ...of detect smoke or no smoke via Lifeline 2 When the sensor detects status change between smoke and no smoke the device will be triggered 6 2 Supported Command Classes 1 Z Wave plus Info Version 2 2 N...

Страница 16: ...lding m 20 related to material of walls Tamper protection No Firmware updateable No Support Z Wave Beaming No SmartStart supported No Z Wave Network Security Yes Z Wave AES 128 Security Yes Z Wave Plu...

Отзывы: