The screw must be fully screwed into
the recess provided on the magnetic
mount to ensure that the unit is held
securely. Take care not to fasten the
screw too tightly as this could deform/
distort the magnetic mount.
THE SMOKE ALARM SHOULD NOT BE
INSTALLED IN THE FOLLOWING AREAS
• outside (use only in internal rooms);
• in areas in which the alarm can be
triggered by disturbances (steam,
condensation, ‘normal’ smoke, fumes,
dust, dirt or grease);
• next to ventilation or similar air inlets
(draughts);
• in areas where temperatures may fall
below 0° C or exceed 40° C.
GENERAL SAFETY INFORMATION
Although smoke alarms can help you
to detect a fire early on, they cannot
extinguish a fire, prevent a fire from
occurring or alarm the fire brigade.
In the event of fire fume-related risk,
smoke alarms emit a loud alarm tone
to warn you of this risk. Although the
utmost care is taken during the
manufacture of the smoke alarm,
a malfunction may occur and a unit
may not be able to warn you of a fire
in due time, or may not be able to
provide a warning at all. The standard
precautions for dealing with fire,
flammable materials and technical
devices must be observed at all times.
The unit is a closed system. Any form
of tampering with the unit’s interior
will result in the loss of any existing
warranty and make it impossible for
the unit to be implemented in
accordance with its intended use.
Never open the unit as this can place
you at risk of injury.
Replacing the battery is not neces-
Fig. 4
sticker and the protective film from the
applied adhesive and press the
magnet carrying frame to the assembly
position firmly for approx. 10 seconds.
Then you can place the device on the
magnet carrying frame (Fig. 1, III.). The
adhesive bond will reach its ultimate
strength after approx. 72 hours.
DRILLING
Drill a hole into the installation surface
with a 8 mm drill bit and insert the
supplied 8 mm wall plug into the hole.
Guide the supplied
5 mm countersunk head screw through
the underside of the magnetic mount
(Fig. 4) pictured below so that the
screw with be flush with the magnetic
mount when it has been screwed into
the wall plug. Push the screw through
the drilled hole.
Fig. 3
pressing the test and stop button (IV).
If the smoke alarm is emitting either
of the above-described signalling tones,
the unit will continue to function for a
maximum of 60 days and needs to be
replaced before this 60-day period has
expired!
INSTALLATION
The RM23 NF is hold in place by a
magnetic mount. This mount can
be fastened to the ceiling in two
different ways, as described below.
Please note that only one side of the
magnet can attract the unit
magnetically.
ADHESIVE MOUNTING
To mount the device using adhesion,
only the adhesive included with the
product may be used! The assembly site
must be fixed, dry and free of grease,
dust and loose paintwork etc. As shown
in (Fig. 3), remove the information
GB