3.4. Overview configuration parameters
Z-Wave products can be used directly after inclusion in the network. However, configuration settings
can be used to adapt the behavior of the device even better to the requirements of the application and
to activate additional functions.
Para-
meter
Byte
size
Function
Default value
(default)
Description
10
1
Threshold value
battery alarm
10
Percentage value from when the low battery
alarm should be transmitted.
Adjustable from
5 - 50
in percent
(Hexadecimal: 0x05 - 0x32)
14
1
BASIC SET to
association
group 2 (motion
alarm)
0
BASIC SET should be sent after a motion
alarm.
0 = Disabled
1 = Active
(Hexadecimal: 0x00 - 0x01)
15
1
Invert value of
BASIC SET
command
0
Set the value of the BASIC SET command for
movement alarm and acknowledgement.
0 = The motion alarm sends the BASIC
SET value "On" (0xFF), the
acknowledgement sends the BASIC SET
value "Off" (0x00)
1 = The motion alarm sends the BASIC
SET value "Off" (0x00), the
acknowledgement sends the BASIC SET
value "On" (0xFF)
(Hexadecimal: 0x00 - 0x01)
32
1
Bypass function
0
Enables or disables the bypass function.
0 = Bypass function activated
1 = Bypass function deactivated
(Hexadecimal: 0x00 - 0x01)