Camera
43
Videoquality diagnostics
Select the camera channel to be processed under
"Camera".
Tick the
"Enable Video Quality Diagnostics"
box and
define any other optional parameters under
"Settings"
.
Video Quality Diagnostics is activated if the limits in the
camera image for image sharpness, brightness and
colour are exceeded. The limits can be set using the
scroll bar. The lower the value, the sooner an alarm is
detected.
Arming Schedule
Select the
Arming Schedule
tab.
Here you set the times at which the reactions set in the
Linkage Action
tab are triggered.
1. Select the day and enter the schedule.
Note
You can define up to eight time slots, between
00:00 and 00:00 in each case, but the individual
time slots must not overlap.
2. Under
Copy
, select whether or not the setting should
be applied to every day of the week and the holiday
settings.
3. Confirm the settings by clicking on
Apply
and exit
the menu by clicking on
OK.
Linkage Action
Select the
Linkage Action
tab.
Here you can configure the response of the recorder
during an event (e.g. motion detected) by ticking the
corresponding box.
Parameter
Notifications
Full Screen Monitoring
The camera is displayed in
full screen in live view.
Audible Warning
The device emits a
repeated signal tone.
Notify Surveillance
Center
The CMS sends out a
warning message.
Send Email
An email is sent to a
specified email address.
See page 29.
Trigger Alarm Output
The alarm output is
triggered in the event of an
alarm.
Confirm the settings by clicking on
Apply
and exit
the menu by clicking on
OK.