GB
Environmental class
II (EN 50131-1 + A1:2009 Section 7)
Protection class, IP protec-
tion class
IP34 (internal spaces, in its installed state)
IP = international protection or ingress protection
3 = tools and wires
4 = splashing water
Operating temperature
-10°C to 40°C
Humidity, max.
Non-condensing average relative humidity approx. 75%
Housing material
PC/ABS
Dimensions (W x H x D)
130 x 154 x 40 mm
Weight
218 g (without batteries)
310 g with batteries
4 x approx. 23 g (92 g) batteries alone
Security level
Grade 2 (EN 50131-1 + A1:2009 Section 6)
Tamper protection
(detection/protection)
Type B (EN50131-3 Section 8.7)
Signal generation
Integrated piezo sounder
Sound pressure level
> 80 dB(A) @ 1 m
Switch-off time
The device will be automatically muted after three minutes when in battery mode
Displays
3 status LEDs for software status and signal strength
Connections
12 V DC IN
Screw terminal
BATT1 and BATT2
2 battery compartments with space for 2 batteries each
Type of power supply
Type B (50131-1 Section 9 and 50131-6 Section 4.1) for external power supply via power supply unit and batteries
inserted as a backup power supply. Type C (50131-1 Section 9 and 50131-6 Section 4.1) for battery operation only,
without external power supply via power supply unit. Power supply compliant with EN50131-1:2006+A1:2009 9.2
and EN50131-6 if installed correctly together with Secvest FUAA50xxx.
Operating voltage
6–15 V DC, 12 V nominal (external power supply unit) and 6 V DC (batteries) or 6 V DC (batteries)
Battery type
4 x AA alkaline batteries
Duracell Procell MN1500, Duracell Industrial ID1500, Energizer E91
Standby time of the
energy
storage system
Type W (EN 50131-4:2009 Section 5.6.3.2) for battery operation only, without external power supply via power
supply unit. Type X(EN 50131-4:2009 Section 5.6.3.2) external power supply via power supply unit and batteries
inserted as a backup power supply.
Battery undervoltage
threshold
4.5 V
“Flat battery” fault at <4.5 V
Voltage monitoring
During battery operation without any external power supply, only the voltage provided by the batteries is
monitored. If the voltage is below the lower threshold of 4.5 V, a fault report is sent to the alarm control panel
and the user is informed. The external power supply is not monitored in this mode. During operation with an
external power supply, a fault report is sent to the alarm control panel as soon as the external power supply is
interrupted. The internal sounder then automatically continues to be powered by the batteries. The corresponding
notification on the alarm control panel informs the user about this. The batteries can be monitored as described
above.
Operating frequency
868.6625 MHz narrow band
Wireless power output
max. 10 mW
Transmission and
reception range
max. 500 m range outdoors
Standards for intrusion
and panic button devices
Complies with EN 50131-1:2006+A1:2009, EN 50131-3:2009, EN 50131-4:2009, EN 50131-5-3:2005+A1:2008 and EN
50131-6:2008+A1:2014 security level 2 if installed correctly together with the Secvest FUAA50xxx (verified by ANPI).
EU Directives
RED: 2014/53/EU, EMC: 2014/30/EU, RoHS: 2011/65/EU, WEEE: 2012/19/EU, ErP: 2009/125/EU, Low voltage: 2014/35/EU,
General safety: 2001/95/EC
General
This product must be installed by a qualified service engineer.