Functional principle and features
25 |
E N
Rest period
To increase the battery life and to prevent unnecessary radio emissions, a rest period function is
integrated in the detector. It lasts for 3 minutes after each detection.
To make it easier for you to test the detector, the rest period lasts for only 7 seconds within the first
30 minutes after installing the battery or after activating the tamper switch.
Compatible equipment
•
FUAA50xxx Secvest alarm panels
•
FUMO50010 Repeater Secvest
•
FUMO50020 Universal module Secvest
•
Wireless extensions Terxon MX and LX (IR programming)
•
FU8000 and FU5000 Secvest alarm control panels
Position
The motion detector may only be installed upright
Note
To ensure trouble-free operation, the detector must NOT be installed:
•
opposite heat sources or windows
•
above a radiator
•
close to the ground
•
closer than 30 mm to the ceiling
•
behind cupboards, room partitions and partition walls
•
at a distance of less than 1 m from large metal structures (such as metal
doors or frames, water tanks, refrigerators), household electrical systems,
power distributors or metal pipes
•
inside metal housings
•
close to the main power supply, or close to water or gas pipelines
•
close to high-voltage devices or electronic devices such as computers,
photocopiers or other wireless devices
•
close to fluorescent lighting.
The following wall material can lead to a reduction in the wireless range:
•
bricks
•
steel-reinforced concrete, reinforced concrete
•
corrugated sheet metal.