Installation
32 |
E N
Step 4: Closing the housing
•
Close the cover and tighten the cover fixing screws.
Step 5: Test the system
•
Set the alarm system to walk test mode (see corresponding user guide).
•
Leave the area monitored by the detector and wait for the rest period after each test (see
“Rest period”).
•
Carry out several walk tests to test the surveillance area.
•
If the detector is triggered when it is not meant to be triggered, please check the installation
location of the detector again (see “Position”).
Note
A 30-minute walk test period is integrated in the detector. It begins when the
batteries are inserted or when the tamper contact is opened.
The LED is activated during this period and the 3-minute rest period is deactivated.
The detector can be triggered again during this period approx. 7 seconds after
completion of the last HF transmission.