17
Installing the arming station
1. Open the arming station housing by removing the screws
on the bottom side.
2. Using the base plate as a drilling template, mark the drill
holes on the wall. Drill the holes and insert the wall plugs.
3. To fit battery push into location with the positive contact
towards the “+”. To replace battery remove old battery
from mount and replace as above. Dispose of old battery
as instructed above.
4. For Prox coil facility the arming station should be
connected to an external power source, connect 12DC /
100 mA to TB1 marked “DC in” 0V and 12V as indicated.
5. Screw the rear side of the housing to the wall.
6. Train the arming station and then close the cover again.
Learning procedure
1. Set the Secvest to learning mode (see the alarm centre
installation instructions) and send a tamper message from
the arming station to the wireless
alarm system.
2. The wireless alarm system emits a double tone
when the learn signal is received correctly.
The signal strength is also displayed.
3. Confirm the successful learning procedure on
the system.