34
3.5 Dip
switches
The dip switches have the following meanings:
1. OFF:
The IP alarm module trains wireless transmitters via
infrared LED only.
ON:
The IP alarm module trains wireless transmitters via
wireless protocol only.
2. OFF: The IP alarm module does not monitor jamming.
ON:
The IP alarm module monitors jamming.
3. OFF:
The IP alarm module does not monitor the detectors
for supervision.
ON:
The IP alarm module monitors the detectors for
supervision failures.
4. OFF:
Short supervision time (20 minutes).
ON:
Long supervision time (3 hours).
5. Must be set to OFF.
6. Must be set to ON.
7. Must be set to ON.
8. Must be set to OFF.