13
control shows the number of the learned components
with the display “t 2” alternating with the signal strength.
Important:
If radio components cannot be trained, the
extension module emits a single tone.
3. Repeat steps 2 and 3 to train further radio components.
Note that max. 8 radio remote controls can be trained.
6.3
Assigning sensors to zones
1. Put the extension module in learn mode.
2.
Press “SELECT” until the desired zone number ap-
pears.
If the display flashes, the zone is free. If the display is
constant, the zone is occupied.
3.
Follow steps 2 and 3 from the section “Training radio
components”.
6.4
Deleting sensors
1. Put the extension module in learn mode.
2.
Press “SELECT” until the desired zone number ap-
pears.
3.
Press “DELETE” for about 4 seconds. A double tone
sounds and the display shows “--”. The sensor is now
deletedBetriebshinweise
6.5
Deleting additional devices
These components cannot be deleted individually. To delete a
component, you have to delete all radio remote controls and
then retrain the ones you want to keep.
7. Operation
The radio extension module can detect different errors and
faults in the radio components and transmit them to the alarm
centre.
7.1
Anzeige der Signalstärke
1. Put the extension module in learn mode.
2.
Press “SELECT” until the desired zone number or radio
remote control number appears. Both LEDs on the PCB
must be off.
3. Activate the corresponding radio component. The green
LED (Pass) shows that the signal strength is sufficient.
The red LED (Fail) shows that the signal strength is not
sufficient. The display shows the signal strength and
the zone number alternatingly.