background image

Page 4 of 7

INTRODUCTION:

 

The ADE-10 is a 3-stage analog waveshaping, wavefolding and feedback

 

effect in a 10HP module in the Eurorack format.

 

The 3 stages are arranged in series so any 1 stage can be operated

 

independently or combined with either of the other 2 stages.

 

All 3 stages can be modulated manually or via dedicated external CV inputs,

 

which can also be attenuated and biased directly from the front panel.

 

All inputs and outputs are DC-coupled and input and output signal levels

 

can be gained or attenuated at both the pre- and post-effect stage.

 

All inputs are capable of accepting signals within a range of approximately

 

+/-10V AC or DC and, under normal operating conditions, should work with

 

any signal level generated within the Eurorack format.

 

Simultaneous outputs provide a FULL-WAVE output for +/- AC and DC signals

 

and a HALF-WAVE rectified output for positive AC and positive DC signals.

 

INTEGRATION:

 

The ADE-10 is designed to work best with simple, symmetrical, angular and

 

non-rectangular waveforms (i.e. sine, triangle and sawtooth) and most

 

waveforms derived from combinations of these initial waveform shapes.

 

The ADE-10 can also work with envelope generator and CV signals created

 

from square, pulse, gate and trigger signals fed via a lag generator to ‘round’

 

the edges of the input signal.

 

The ADE-10 is frequency and waveform independent - it operates across

 

the complete ‘musical’ frequency range from audio to LFO and CV.

 

The shaping stages produce effects from subtle phasing to more aggressive

 

PWM-style sounds. The feedback circuit can add soft, bell-like resonance to

 

simpler waveforms or harsher saturation to more complex waveforms.

 

The output of each stage will vary slightly based on the type of waveform that

 

is used as the initial input. This is due to the way the ADE-10 adds and reacts

 

to the harmonic content of the input waveform and then, in turn, the output

 

waveform of the preceding stage - thus, the term ‘reactive’ - each stage is

 

a reaction to the stage that precedes it.

OPERATION:

 

Setting up the ADE-10 for optimal use is easy and for first-time users, these

 

simple steps should get you started:

 

1) Secure the ADE-10 into a rack using the correct mounting screws, connect

 

  the rack’s internal power supply and turn the power on (

Please see

 

  ‘PRECAUTIONS’ 

on page 7 of this guide

);

 

2) Lower all knobs on the ADE-10 to fully counter-clockwise (0%);

 

3) Connect the output of a VCO to the SIGNAL IN of the ADE-10. If possible,

 

  use a sine wave output as this will demonstrate the full harmonic potential

 

  of the ADE-10;

 

4) Connect the FULL-WAVE output of the ADE-10 to the Input stage of

 

  another module or some type of AC-coupled output stage (

Please see

 

  ‘CALIBRATION’ 

on page 7 of this guide

);

 

5) Raise the INPUT GAIN/ATTEN knob until shaping is triggered (depending

 

  on the volume of your initial input this should be at approx. 50%, you might

 

  hear a change to a more square-like sound at this threshold. If not - that is

 

  fine, your input is below the triggering threshold and you’re good to go) -

 

  then lower the INPUT GAIN/ATTEN knob to just below this threshold;

 

6) Raise the OUTPUT GAIN/ATTEN to approximately half-way (50%) or to a

 

  level that suits the requirements of the module the ADE-10 is plugged in to;

 

7) Start making noises. 

© 2011 Abstract Data Ltd.

http://www.abstractdata.biz

[email protected]

Version 1.0 October 2011

4: Overview

Содержание ADE-10

Страница 1: ... 2011 Abstract Data Ltd http www abstractdata biz info abstractdata biz Version 1 0 October 2011 64 3 6 3 5 7 4 1 3 3 Stage Shaping Folding Feedback Module with Dedicated CV Control and Dual Outputs ...

Страница 2: ...GAIN ATTEN Post effect gain attenuation up to 50 at the full and half wave outputs STAGE 1 CV IN DC coupled input for external CV Accepts up to 10V AC and DC signals STAGE 2 CV IN DC coupled input for external CV Accepts up to 10V AC and DC signals STAGE 3 CV IN DC coupled input for external CV Accepts up to 10V AC and DC signals SIGNAL IN Main DC coupled input Accepts up to 10V AC and DC signals ...

Страница 3: ...tion The RED stripe on the supplied power cable connects to the NEGATIVE 12V rail on the ADE 10 with the RED stripe facing DOWN This is marked on the back of the ADE 10 PCB as 12 RED Please see PRECAUTIONS on page 7 of this guide 2011 Abstract Data Ltd http www abstractdata biz info abstractdata biz Version 1 0 October 2011 2 Rear 3 Signal Flow STAGE 1 SHAPING STAGE 2 FOLDING STAGE 3 FEEDBACK OUTP...

Страница 4: ...l like resonance to simpler waveforms or harsher saturation to more complex waveforms The output of each stage will vary slightly based on the type of waveform that is used as the initial input This is due to the way the ADE 10 adds and reacts to the harmonic content of the input waveform and then in turn the output waveform of the preceding stage thus the term reactive each stage is a reaction to...

Страница 5: ... raised the effect on the waveform evolves through the input signal from dry to wet n b Input signals other than audio can be shaped and effected and this diagram should be considered as a starting point for further experimentaion Please see INTEGRATION on page 4 of this guide 2011 Abstract Data Ltd http www abstractdata biz info abstractdata biz Version 1 0 October 2011 5 Shaping STAGE 1 SINE STA...

Страница 6: ...g n b For this diagram bias refers to the manual modulation control e g STAGE 1 MOD for each stage and level refers to the external CV input control e g STAGE 1 CV for each stage 2011 Abstract Data Ltd http www abstractdata biz info abstractdata biz Version 1 0 October 2011 6 CV CV BIAS 0 CV LEVEL 0 0V 5V 5V 0V 5V 5V 0V 5V 5V CV BIAS 50 CV LEVEL 0 CV BIAS 75 CV LEVEL 0 CV BIAS 0 CV LEVEL 50 CV BIA...

Страница 7: ...ny DC content present at the input will also be present at the output Additionally a non calibrated ADE 10 can also add a small amount of DC content to the output waveform Each ADE 10 is calibrated before shipping and once set the output should remain at close to 0V DC with all front panel controls set to 0 and no inputs connected For advice on calibrating the ADE 10 please contact Abstract Data P...

Отзывы: