background image

DC to Frequency Transmitters, Isolated, Field Rangeable 

API 7500 G, API 7500 G SS

Input:

 

0-50 mV to ±10 VDC, 0-1 mA to 4-20 mA

Output:

  0-1 Hz to 0-30 kHz MOSFET or TTL

 

O

24 Selectable Inputs and 30 Selectable Outputs

 

O

Setup via Rotary Switches & Easy-to-Use Tables

 

O

2000 V Full Isolation Input/Output/Power

 

O

Adjustable Low Frequency Cutout

 

O

Input and Output LoopTracker

®

 LEDs

 

O

Functional Test Push Button

 

Q

Analog to Frequency for Totalizers and Counters

 

Q

Use With API 7580 for Remote Monitoring

Applications

Model

Input

Output

Power

API 7500 G

Field rangeable  

voltage or milliamps  

0-50 mVDC to ±10 VDC 

0-1 mADC to 0-20 mADC

Field rangeable  

0-100 Hz to 0-30 kHz

115 VAC

API 7500 G A230

230 VAC

API 7500 G P

85-265 VAC or 60-300 VDC

API 7500 G D

9-30 VDC

API 7500 G SS

Field rangeable  

Low range version 

0-1 Hz to 0-300 Hz

115 VAC

API 7500 G SS A230

230 VAC

API 7500 G SS P

85-265 VAC or 60-300 VDC

API 7500 G SS D

9-30 VDC

Description

The API 7500 G accepts a DC voltage or current input and 
provides an optically isolated frequency output that is directly 
proportional to the input. Common applications include pulse 
counting or totalizing of DC process signals from devices such 
as flow transmitters, analog signal transmission over long 
distances, or analog inputs into PLCs. The full 3-way (input, 
output, power) isolation makes this module useful for ground 
loop elimination, common mode signal rejection, and noise 
pickup reduction.
A low frequency cutout potentiometer can be adjusted to dis-
able the output when the input falls below a pre-determined 
level. The API 7500 G can be field-configured via external 
rotary and slide switches. Common ranges are on the module 
label, however, virtually unlimited combinations are possible. 
The API 7500 G has an open drain MOSFET (open collector) 
output which requires a user supplied external power supply 
and pull-up resistor allowing the module to be interfaced with 
a wide variety of devices. For a TTL powered output, order the 
M02 option.

Sink/Source Versatility

For maximum versatility the input can be selectively wired for 
sinking (unpowered) or sourcing (powered) milliamp output.
The 18 VDC loop excitation supply can be used to power a 
milliamp current loop if required. The input can also be wired 
for an externally powered loop.

LoopTracker 

API exclusive features include two LoopTracker LEDs (green for 
input, red for output) that vary in intensity with changes in the 
process input and output signals. These provide a quick visual 
picture of your process loop at all times and can greatly aid in 
saving time during initial startup and/or troubleshooting. 

Output Test 

An API exclusive feature includes the test button to provide a 
fixed output (independent of the input) when held depressed. 
The test output level is potentiometer adjustable from 0 to 
100% of the output span.
The output test button greatly aids in saving time during initial 
startup and/or troubleshooting.

DC Input Ranges

 

Voltage: 

0-50 mVDC to ±10 VDC 

Current: 

0-1 mADC to 0-20 mADC including 4-20 mA 

 

mA input may be wired for sink or source 

Consult factory for other ranges 
System voltages must not exceed socket voltage rating

Input Impedance

Voltage: 

1 M

 minimum 

Current: 50 

 typical

Input Loop Power Supply

18 VDC nom., unregulated, 25 mADC, max. ripple, <1.5 V

p-p

LoopTracker

Variable brightness LEDs indicate I/O loop level and status

Frequency Output Ranges

 

Minimum  Maximum Increments 

Low range: 

0-100 Hz  

0-1500 Hz   100 Hz 

High range: 

0-2 kHz  

0-30 kHz 

2 kHz

Frequency Output Ranges, SS Version

 

Minimum  Maximum Increments

SS low range:  0-1 Hz 

0-15 Hz 

1 Hz

SS high range:  0-20 Hz 

0-300 Hz 

20 Hz

Output Waveform and Type

Square wave 
Normal acting, output freq. increases with increasing input

Output Driver

MOSFET output, open drain, 24 VDC maximum 
I

sink

 

50 mA maximum 

V

on

 

0.6 V maximum at 50 mA I

sink

M02 option:   TTL output 1 V

p-p

 to 12 V

p-p

 depending on load

Cutout Control

Disables output when input falls below preset level 
Adjustable from 2% to 25% of range 
Top accessible, multi-turn potentiometer

Output Calibration

 

Multi-turn zero and span potentiometers  
±15% of selected span typical

Output Test

Pressing top button sets output to test level  
Potentiometer adjustable 2-100% of span

Linearity

Better than ±0.4% of span

Ambient Temperature Range and Stability

–10°C to +60°C operating ambient 

Better than ±0.02% of span per °C stability

Response Time

70 milliseconds typical 
Consult factory for faster response times

Isolation

2000 V

RMS

 minimum 

Full isolation: power to input, power to output, input to output

Installation Environment

IP 40, requires installation in panel or enclosure 
Use with API 008 or API 008 FS socket
Socket mounts to 35 mm DIN rail or can be surface mounted
UL 508C pollution degree 2 environments or bettert

Power

Standard: 

115 VAC ±10%, 50/60 Hz, 2.5 W max. 

A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max. 
P option: 

85-265 VAC 50/60 Hz, 60-300 VDC 2.5 W typ. 

D option:  

9-30 VDC, 1.5 W typical

Quick Link 

api-usa.com/7500

Free Factory 

I/O Setup!

Options—add to end of model number
M02

 

TTL powered output instead of MOSFET output 

M03

 

Adjustable signal generator, no input 

U

 

Conformal coating for moisture resistance

Accessories—order as separate line item
API 008

 

8-pin socket

API 008 FS

  8-pin finger-safe socket 

API CLP1

  Module hold-down spring for high vibration or  

 

mobile applications

2.75"

Minute 

Setup!

1

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

2.38"

1.75"

Variable Brightness 

Input LED

Output Test Button

Output Zero
Output Span
Cutout Adjust
Output Test 

Adjust

Variable Brightness 

Output LED

Hot Swappable 

Plug-In Design

API 008 

600 V Rating

API 008 FS 

300 V Rating

API CLP1

E145968

115 VAC, 230 VAC  

models

© 08-19

api-usa.com

1220 American Way Libertyville, IL 60048 
Phone: 

800-942-0315

 

Fax: 800-949-7502

A

BSOLUTE

 P

ROCESS

 I

NSTRUMENTS

Отзывы: