Frequency to DC Transmitters, Isolated, Field Rangeable
APD 7580
Input:
0-100 Hz to 0-30 kHz
Output:
0-1 V to 0-10 VDC, ±5 VDC, ±10 VDC, 0-2 mA to 20 mADC
O
1 Minute Setup for 30 Input & 18 Output Ranges
O
External Switches & Tables for Range Selection
O
Zero and Span Output Calibration Potentiometers
O
Full 1200 V Input/Output/Power Isolation
O
Input and Output LoopTracker
®
LEDs
O
Output Test Button
O
Built-In Loop Power Supply for Sink/Source Output
Q
Monitor and Control Motor or Line Speed
Q
Convert Speed and Frequency Signals
Applications
Option—add to end of model number
U
Conformal coating for moisture resistance
Accessory—order as separate line item
API BP4
Spare removable 4 terminal plug, black
Model
Input
Output
Power
APD 7580
Field configurable
0-100 Hz to 0-30 kHz
Field configurable
voltage or milliamp ranges
85-265 VAC or 60-300 VDC
APD 7580 D
9-30 VDC or 10-32 VAC
Description
The APD 7580 accepts a frequency input and provides an
optically isolated DC voltage or current output that is linearly
related to the input.
Common applications include frequency to DC conversions
from frequency output type devices such as rotary encoders,
magnetic pick-ups, proximity sensors, variable speed drives,
and flow meters. For PLCs that do not have analog outputs,
often the pulse rate of a discreet output can be programmed to
vary. By connecting the APD 7580 to this output, a proportional
analog signal can be generated. A 15 VDC power supply is
provided to power the sensor input, if required.
Full 3-way isolation (input, output, power) makes this module
useful for ground loop elimination, common mode signal rejec-
tion or noise pickup reduction.
The APD 7580 input and output can be field-configured via
external rotary and slide switches. Common ranges are on
the module label. Many additional combinations are possible.
Consult the factory for assistance with special ranges.
Sink/Source Versatility
For maximum versatility the output can be selectively wired for
sinking (unpowered) or sourcing (powered) milliamp output.
The 20 VDC loop excitation supply can be used to power a mil-
liamp current loop if required. The output can also be wired for
an externally powered loop.
LoopTracker
API exclusive features include two LoopTracker LEDs (green for
input, red for output) that vary in intensity with changes in the
process input and output signals. These provide a quick visual
picture of your process loop at all times and can greatly aid in
saving time during initial startup and/or troubleshooting.
Output Test
An API exclusive feature includes the test button to provide a
fixed output (independent of the input) when held depressed.
The test output level is potentiometer adjustable from 0 to
100% of output span.
The output test button greatly aids in saving time during initial
startup and/or troubleshooting.
All models are field rangeable
For APD 7580, specify if UL version is required
Order options and accessories as required
Order D versions for operation on low voltage power
How to Order
Free factory setup. Please specify on your order
Input range
Output range
Frequency Input Ranges
0-100 Hz to 0-30 kHz, 30 switch selectable input ranges
Minimum pulse width 5 µsec
Input Impedance
10 k
Ω
nominal (maximum sensitivity)
100 k
Ω
nominal (minimum sensitivity)
Input Sensitivity/Hysteresis
Multi-turn potentiometer for sensitivity adjustment
Maximum sensitivity:
±25 mV typical
Minimum sensitivity:
±2.5 V typical
Input Amplitude Range
100 mV to 150 V
RMS
Any waveform with minimum 100 mV amplitude change
Input Power Supply
15 VDC ±10%, regulated, 25 mADC
Max. ripple, less than 10 mV
RMS
May be used to power sensor
LoopTracker
Variable brightness LEDs indicate I/O loop level and status
DC Output Ranges
Switch selectable, field rangeable
Voltage:
0-1 VDC
to 0-10 VDC, 10 mA max
Bipolar voltage: ±1 VDC
to ±10 VDC
Current:
0-2 mADC to 0-20 mADC
20 V compliance, 1000
Ω
at 20 mA
Output Calibration
Multi-turn zero and span potentiometers
±15% of zero adjustment, ±10% of span adjustment typical
Output Loop Power Supply
20 VDC nominal, regulated, 25 mADC
Max. ripple, less than 10 mV
RMS
May be selectively wired for sinking or sourcing mA output
Output Test
Front momentary button sets output to test level
Potentiometer adjustable 0-100% of span
Output Ripple and Noise
Less than 10 mV
RMS
ripple and noise
Linearity
Better than ±0.8% of span
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than ±0.02% of span per °C stability
Isolation
1200 V
RMS
minimum
Full isolation: power to input, power to output, input to output
Power
85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximum
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum
Housing and Connectors
IP 40, requires installation in panel or enclosure
For use in Pollution Degree 2 Environment
Mount vertically to a 35 mm DIN rail
Four 4-terminal removable connectors, 14 AWG max wire size
Dimensions
0.89" W x 4.62" H x 4.81" D
22.5 mm W x 117 mm H x 122 mm D
Height includes connectors
15 VDC sensor
Power Available
Output LoopTracker
LED
Input LoopTracker
LED
Adjustable Output
Test Function
Connect mA Output
for Sink or Source
Hundreds of Range
Selections
Adjustable Input
Sensitivity
Universal
Power
Zero and Span for
Output
Removable Plugs
© 02-20
api-usa.com
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
Fax: 800-949-7502
A
A
BSOLUTE
BSOLUTE
P
P
ROCESS
ROCESS
I
I
NSTRUMENTS
NSTRUMENTS
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
See Wiring
Diagrams on
Next Page
Quick Link:
api-usa.com/7580
Minute
Setup!
1
Free Factory
I/O Setup!
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
File E145968
85-265 VAC, 60-300 VDC
model only
Applications Link
api-usa.com/apps
Pb
Lead