Frequency to DC Transmitters, Isolated, Field Rangeable 

APD 7580

Input:

 

0-100 Hz to 0-30 kHz

Output:

  0-1 V to 0-10 VDC, ±5 VDC, ±10 VDC, 0-2 mA to 20 mADC

 

O

1 Minute Setup for 30 Input & 18 Output Ranges

 

O

External Switches & Tables for Range Selection

 

O

Zero and Span Output Calibration Potentiometers

 

O

Full 1200 V Input/Output/Power Isolation

 

O

Input and Output LoopTracker

®

 LEDs

 

O

Output Test Button

 

O

Built-In Loop Power Supply for Sink/Source Output

 

Q

Monitor and Control Motor or Line Speed

 

Q

Convert Speed and Frequency Signals

Applications

Option—add to end of model number
U

 

Conformal coating for moisture resistance

Accessory—order as separate line item
API BP4

  Spare removable 4 terminal plug, black

Model

Input

Output

Power

APD 7580

Field configurable  

0-100 Hz to 0-30 kHz

Field configurable  

voltage or milliamp ranges

85-265 VAC or 60-300 VDC

APD 7580 D

9-30 VDC or 10-32 VAC

Description

The APD 7580 accepts a frequency input and provides an 
optically isolated DC voltage or current output that is linearly 
related to the input. 
Common applications include frequency to DC conversions 
from frequency output type devices such as rotary encoders, 
magnetic pick-ups, proximity sensors, variable speed drives, 
and flow meters. For PLCs that do not have analog outputs, 
often the pulse rate of a discreet output can be programmed to 
vary. By connecting the APD 7580 to this output, a proportional 
analog signal can be generated. A 15 VDC power supply is 
provided to power the sensor input, if required.
Full 3-way isolation (input, output, power) makes this module 
useful for ground loop elimination, common mode signal rejec-
tion or noise pickup reduction.
The APD 7580 input and output can be field-configured via 
external rotary and slide switches. Common ranges are on 
the module label. Many additional combinations are possible. 
Consult the factory for assistance with special ranges.

Sink/Source Versatility

For maximum versatility the output can be selectively wired for 
sinking (unpowered) or sourcing (powered) milliamp output.
The 20 VDC loop excitation supply can be used to power a mil-
liamp current loop if required. The output can also be wired for 
an externally powered loop.

LoopTracker 

API exclusive features include two LoopTracker LEDs (green for 
input, red for output) that vary in intensity with changes in the 
process input and output signals. These provide a quick visual 
picture of your process loop at all times and can greatly aid in 
saving time during initial startup and/or troubleshooting. 

Output Test 

An API exclusive feature includes the test button to provide a 
fixed output (independent of the input) when held depressed. 
The test output level is potentiometer adjustable from 0 to 
100% of output span. 
The output test button greatly aids in saving time during initial 
startup and/or troubleshooting.

All models are field rangeable

For APD 7580, specify if UL version is required 
Order options and accessories as required 
Order D versions for operation on low voltage power

How to Order

Free factory setup. Please specify on your order

 

Input range 
Output range

Frequency Input Ranges 

0-100 Hz to 0-30 kHz, 30 switch selectable input ranges 
Minimum pulse width 5 µsec

Input Impedance

10 k

 nominal (maximum sensitivity)

100 k

 nominal (minimum sensitivity)

Input Sensitivity/Hysteresis

Multi-turn potentiometer for sensitivity adjustment
Maximum sensitivity: 

±25 mV typical 

Minimum sensitivity: 

±2.5 V typical

Input Amplitude Range

100 mV to 150 V

RMS

 

Any waveform with minimum 100 mV amplitude change

Input Power Supply

15 VDC ±10%, regulated, 25 mADC 
Max. ripple, less than 10 mV

RMS

May be used to power sensor

LoopTracker

Variable brightness LEDs indicate I/O loop level and status

DC Output Ranges

Switch selectable, field rangeable
Voltage: 

0-1 VDC 

to  0-10 VDC, 10 mA max 

Bipolar voltage:  ±1 VDC 

to  ±10 VDC 

Current: 

0-2 mADC  to  0-20 mADC 

 

20 V compliance, 1000 

 at 20 mA

Output Calibration

Multi-turn zero and span potentiometers  
±15% of zero adjustment, ±10% of span adjustment typical

Output Loop Power Supply

20 VDC nominal, regulated, 25 mADC 
Max. ripple, less than 10 mV

RMS

May be selectively wired for sinking or sourcing mA output

Output Test

Front momentary button sets output to test level 
Potentiometer adjustable 0-100% of span

Output Ripple and Noise

Less than 10 mV

RMS

 ripple and noise

Linearity

Better than ±0.8% of span

Ambient Temperature Range and Stability

–10°C to +60°C operating ambient 
Better than ±0.02% of span per °C stability

Isolation

1200 V

RMS

 minimum 

Full isolation: power to input, power to output, input to output

Power

85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximum 
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum

Housing and Connectors

IP 40, requires installation in panel or enclosure 
For use in Pollution Degree 2 Environment 
Mount vertically to a 35 mm DIN rail 
Four 4-terminal removable connectors, 14 AWG max wire size

Dimensions

0.89" W x 4.62" H x 4.81" D   
22.5 mm W x 117 mm H x 122 mm D  
Height includes connectors

15 VDC sensor 

Power Available

Output LoopTracker 

LED

Input LoopTracker 

LED

Adjustable Output 

Test Function

Connect mA Output 

for Sink or Source

Hundreds of Range 

Selections

Adjustable Input 

Sensitivity

Universal 

Power

Zero and Span for 

Output

Removable Plugs

© 02-20

api-usa.com

1220 American Way Libertyville, IL 60048 
Phone: 

800-942-0315

 

Fax: 800-949-7502

A

A

BSOLUTE

BSOLUTE

 P

 P

ROCESS

ROCESS

 I

 I

NSTRUMENTS

NSTRUMENTS

1  2  3  4

5  6  7  8

9 10 11 12

13 14 15 16

See Wiring 

Diagrams on 

Next Page

Quick Link: 

api-usa.com/7580

Minute 

Setup!

1

Free Factory 

I/O Setup!

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

File E145968

85-265 VAC, 60-300 VDC 

model only

Applications Link 

api-usa.com/apps

Pb

Lead 

Free

Содержание APD 7580

Страница 1: ...n saving time during initial startup and or troubleshooting All models are field rangeable For APD 7580 specify if UL version is required Order options and accessories as required Order D versions for operation on low voltage power How to Order Free factory setup Please specify on your order Input range Output range Frequency Input Ranges 0 100 Hz to 0 30 kHz 30 switch selectable input ranges Mini...

Страница 2: ...H980V H981V H982V H962V H983V H985V H965V H986V H9B6V H9B8V H980I H981I H982I H962I H983I H985I H965I H986I 0 20 kHz HA80V HA81V HA82V HA62V HA83V HA85V HA65V HA86V HAB6V HAB8V HA80I HA81I HA82I HA62I HA83I HA85I HA65I HA86I 0 22 kHz HB80V HB81V HB82V HB62V HB83V HB85V HB65V HB86V HBB6V HBB8V HB80I HB81I HB82I HB62I HB83I HB85I HB65I HB86I 0 24 kHz HC80V HC81V HC82V HC62V HC83V HC85V HC65V HC86V H...

Страница 3: ...ut is unpowered or passive APD module provides the loop power 10 9 20 V switch E set to I Measuring recording device accepts a mA current input and provides power to the current loop 11 10 switch E set to I Spring Clip Upper Mount Lower Mount Mounting to a DIN Rail Install module vertically on a 35 mm DIN rail in a protective enclosure away from heat sources Do not block air flow Allow 1 25 mm abo...

Страница 4: ...ss and hold the Test button and adjust the Test Cal potentiometer for the desired output level Operation The APD 7580 accepts a frequency input and provides an optically isolated DC voltage or current output that is linearly related to the input The frequency input to the APD 7580 is capacitively coupled to remove any DC component at the input to a comparator whose threshold is determined by the s...

Отзывы: