AB-SLS60
SLS60
EN60335-2-29
BATTERY Max 900Ah Min 140Ah
I
boost
60A I
min
20A
START: 320A 3S ON 120S OFF
RATED INPUT
RATED OUTPUT
VOLTAGE
230V/50Hz
INTENSITY
2.6/5.8A
FUSE
30A
VOLTAGE
12/24V
INTENSITY
30/35A
FUSE
5X80A
IP20
Disconnect the 220V power outlet before plugging in or unplugging the battery clamps.
IMPORTANT: Explosive gas, always place away from flames, sparks or incandescent bodies and
always ensure that the area is well-ventilated when charging the batteries.
Table listing the charging power depending on the position of the switches for SL60:
3. SAFETY REGULATIONS
For the safety of people and property, the following safety guidelines must be observed when using the charger.
1/ To allow for the flammable gases generated at the time of charging, the battery must be charged inside a room
with good ventilation. The product should be kept away from any flame or spark. Please DO NOT smoke when the
charger is in use.
2/ In accordance with the IP20 rating, the product must not be used outside in rain or snow.
3/ Always use grounded power of 220V.
4/ At the time of charging, chargers must always be placed on a flat and not tilted ground.
Output voltage (V)
Load current [A]
Position of the load
button
MIN + 1
12
20A
MIN + 2
12
30A
BOOST+1
12
42A
BOOST+2
12
60A
Position of the load
button
MIN + 1
24
20A
MIN + 2
24
35A
BOOST+1
24
47A
BOOST+2
24
60A