background image

EFIS121 User’s Manual Page 4

2. Hardware Installation

2.1 Connectors description

EFIS121 Fingerprint Scanner is powered over the Ethernet cable (Figure 1). Black box
with 2 Ethernet inputs provides DC power to the scanner (black cable on the picture)
and at the same time connects EFIS121 to the network (yellow cable on the picture).
It’s possible to use 2 types of passive PoE adapter.

The range of supply voltage:  VDC 9-35V
Typical supply DC voltage is 12V.

PoE connector is for EFIS121
LAN connector is for network

Содержание EFIS121

Страница 1: ...ABS Applied Biometric Systems GmbH Rev 0 100 User s Manual EFIS121 Page 1 Ethernet fingerprint image scanner EFIS121 User s Manual...

Страница 2: ...erface _________________________________________________________________________________ 3 1 4 Power supply _____________________________________________________________________________ 3 1 5 Other___...

Страница 3: ...efault IP address 192 168 100 10 port 5000 DHCP optional 1 1 External Dimensions Length 80 mm Width 60 mm Height 15 mm 1 2 Biometric sensor Sweeping fingerprint sensor from Atmel image size 280x440 se...

Страница 4: ...lack box with 2 Ethernet inputs provides DC power to the scanner black cable on the picture and at the same time connects EFIS121 to the network yellow cable on the picture It s possible to use 2 type...

Страница 5: ...the specific parameters If the IP address of EFIS121 is forgotten it s possible to set the default IP address by slide switch The default IP address is 192 168 100 2 port 5000 In order to set default...

Страница 6: ...default address 192 168 100 2 port 5000 and press button Read When you get the device configuration you can press button Reboot The device will be rebooted and takes the network configuration from fla...

Страница 7: ...er and waits a connection from TCP client If TCP client has the connection from EFIS121 the client application can get the fingerprint image and control other feature of device by SDK WEB access provi...

Страница 8: ...p 192 168 100 168 cgi bin control cgi led green off switch on the red led http 192 168 100 168 cgi bin control cgi led red on switch off the red led http 192 168 100 168 cgi bin control cgi led red of...

Страница 9: ...EFIS121 User s Manual Page 9 4 Contact ABS Applied Biometric Systems GmbH Im Bauernbusch 27 12355 Berlin Germany info biometricsys de tel 49 30 6789 2692 fax 49 30 6789 2987...