INSTALLATION  

 

UNCRATING  

Move your new unit as close to the final location as possible before 

unpacking. Remove the wooden planks or skid.  This unit requires a 

minimum of 4 inches of air flow space in back and 3 inches on the 

sides and top.

  Do not store material on the top of this unit.  

 

PLEASE NOTE!

  Your refrigerator or freezer is designed for INDOOR 

USE and should be operated in an air conditioned  space with 

temperature between 65°F to 85°F. 

 

LEVELING

 

 You can level your unit with the screw-type adjustable leveling legs on the front corners of the 

unit.  Turn counterclockwise to raise the corner; turn clockwise to lower it. Leveling legs are 

required in front only.  Unit may have a slight tilt from front to back after legs are installed.  This 

is acceptable and is recommended on this unit. 

 

POWER SOURCE 

This unit is equipped with 18 IN FACTORY SEALED WIRING.  THESE WIRES MUST BE HARD 

WIRED THROUGH SEALED CONDUIT TO THE POWER SOURCE PER NFPA AND NEC. VOLTAGE 

SHOULD NOT VARY MORE THAN 5% FROM SERIAL PLATE RATINGS.  PROTECT THE CIRCUIT 

WITH A 20 AMP DELAY-TYPE FUSE OR CIRCUIT BREAKER.  

 

STARTING  

There are no compressor shipping bolts to loosen or valves to open.  All that is necessary after 

the unit has been properly connected and leveled is to energize the circuit.  When starting this 

new appliance, allow the cabinet to operate a minimum of eight hours, or until it has started 

cycling normally, before placing product in the cabinet.  The motor compressor may start and 

stop several times when the unit is first started or after defrosting, especially if the weather is 

very hot.  This is normal operation of the motor overload protector.  The motor compressor will 

cycle normally as soon as the excess heat has been removed.    

 

DOOR BINS (not applicable to all models) 

 

Your unit may come equipped with storage bins in the door. Because of the temperature 

characteristics of these units, items stored in these bins may not be maintained in the desired 

temperature band. Please restrict the use of these bins for non-critical temperature storage. 

 

 

Содержание ABT-EP-1404

Страница 1: ...ledged by the carrier s agent driver at time of delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be disco...

Страница 2: ...unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left upper wall of the unit For conv...

Страница 3: ...RING UNSEALED CONTAINERS OF CORROSIVE MATERIALS CAN CAUSE PERMANENT DAMAGE TO THIS REFRIGERATION UNIT AND WILL VOID THE WARRANTY ALWAYS WEAR SAFETY GLASSES WHEN WORKING WITH THIS EQUIPMENT ANY UNAUTHO...

Страница 4: ...y receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along wi...

Страница 5: ...ED CONDUIT TO THE POWER SOURCE PER NFPA AND NEC VOLTAGE SHOULD NOT VARY MORE THAN 5 FROM SERIAL PLATE RATINGS PROTECT THE CIRCUIT WITH A 20 AMP DELAY TYPE FUSE OR CIRCUIT BREAKER STARTING There are no...

Страница 6: ...ntact the manufacturer s Technical Support Department before making any adjustments to determine if adjustment is necessary and if so to make sure it is performed properly Both refrigerators and freez...

Страница 7: ...out 2 3 inches of free space along the back and sides of the unit to allow for proper air flow and therefore more even cooling of the product When loading the top shelf avoid blocking the evaporator f...

Страница 8: ...placements are pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerat...

Страница 9: ...ghtly sealed to prevent leakage Door will not close The unit is not level Refer to the Leveling section at the beginning of this manual Check for dirt and debris or items passing through the door seal...

Страница 10: ...removable shelves in dishwasher Exterior and Handles Soap and water Non Abrasive Glass Cleaner Do not use commercial household cleaners ammonia or alcohol to clean handles Use a soft cloth to clean s...

Страница 11: ...y into a floor drain Replace the drain plug when defrosting is complete so warm air does not enter the freezer through the hole Defrosting tips If the frost is soft remove it with a plastic scraper If...

Страница 12: ...Y In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship...

Страница 13: ...od or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage cause...

Отзывы: