manualshive.com logo in svg
background image

 

 Part number 20079, Rev 0 

19 

 

HORIZON SCIENTIFIC, INC. PRODUCT WARRANTY 

Horizon Scientific, Inc. warrants to the original purchaser every new Horizon Scientific, Inc. refrigerated 

unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, when such 

unit is installed, used, and maintained in accordance with provided instructions, for a period of two (2) 

years.  The warranty period starts two weeks from the date of shipment from Horizon Scientific, Inc.  

This  two week period allows ample shipping time so that the warranty will go into effect at 

approximately the same time your equipment is delivered.  Unless subject to prior written agreement 

with

 

Horizon Scientific, Inc., this warranty does not allow for any warranty start deferment greater than 

two weeks from date of shipment due to a delayed installation and/or start-up.  By purchasing any 

product from Horizon Scientific, Inc., you and any entity for which you are purchasing acknowledge and 

agree to each and  every provision contained herein, and all other Notices and Terms provided to 

Purchaser by Horizon Scientific, Inc., which are hereby incorporated. 

Under this warranty, Horizon Scientific, Inc., through its authorized service organizations, will repair, or 

at its option, replace any part found to contain a manufacturing defect in material or workmanship 

without charge to the owner for parts and service labor. Replacement or repaired parts will be 

warranted for only the unexpired portion of the original warranty. Horizon Scientific, Inc. will not 

assume any shipping or cartage costs for parts under warranty. These costs shall be paid by the 

customer. 

ADDITIONAL THREE YEAR COMPRESSOR WARRANTY 

In addition to the two (2) year warranty stated above, Horizon Scientific, Inc. warrants its hermetically 

and semi-hermetically sealed compressors to be free from defects in both material and workmanship 

under normal use and service for a period of three (3) additional years from the end of the initial two (2) 

year warranty period, but not to exceed five (5) years after shipment from Horizon Scientific, Inc. 

Compressors determined by Horizon Scientific, Inc. to have been defective within this extended time 

period will, at Horizon Scientific, Inc.

'

s  option, be either repaired or replaced with a compressor or 

compressor parts of similar design and capacity.   

The three (3) year extended compressor warranty applies only to hermetically and semi-hermetically 

sealed parts of the compressor and does not apply to any other parts or components, including, but not 

limited to, cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting 

equipment, fan assembly or any other electrical components. 

Horizon Scientific, Inc.’s sole obligation under this warranty is limited to either repair or replacement of 

parts, subject to the additional limitations below.  This warranty neither assumes nor authorizes any 

person to assume obligations other than expressly covered by this warranty. 

NO CONSEQUENTIAL DAMAGES.

  Horizon Scientific, Inc. is not responsible for economic loss; profit loss; 

or special, indirect or consequential damages, including without limitation, losses or damages arising 

from contents spoilage claims whether or not on account of refrigeration failure, electrical failure, 

power failure, or compressor failure.  HORIZON SCIENTIFIC, INC.’S MAXIMUM CUMULATIVE LIABILITY 

RELATIVE TO ALL CLAIMS AND LIABILITIES, INCLUDING OBLIGATIONS UNDER ANY INDEMNITY, WHETHER 

OR NOT INSURED, SHALL NOT EXCEED THE COST OF THE PRODUCT(S) GIVING RISE TO THE CLAIM OR 

LIABILITY.

 

 

 

Содержание ABT-2020MP

Страница 1: ...of delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When concealed damage is discovered stop unpacking immediately and contact the carrier immediately to report the claim and request an inspection This should be done as soon as possible and in any case must ...

Страница 2: ...URER S TECHNICAL SERVICE DEPARTMENT please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left upper wall of the unit For convenience you may want to record the following information here for easy access in the future Model number __________________________________ Serial n...

Страница 3: ...ry receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along with a formal request for an inspection report Follow up with a phone call Their contact information can be found on the carrier s web site The second type of shipping damage is concealed damage This t...

Страница 4: ...the screw type adjustable leveling legs on the front corners of the unit Turn counterclockwise to raise the corner turn clockwise to lower it The unit may have a slight tilt from front to back after the legs are installed This is acceptable and is actually recommended POWER SOURCE The supply circuit to this cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial ...

Страница 5: ...ALLATION not applicable to all models Hook shelf clips onto pilaster strips see Illustration Position all four shelf clips equal in distance from the floor for flat shelves Wire shelves are oriented so that cross support bars are facing down Place shelves on shelf clips making sure all corners are seated properly TEMPERATURE CONTROL NOTE The controls are preset at the factory to provide the desire...

Страница 6: ...mum load is about 75 of the chamber volume Additionally the load should be distributed evenly from top to bottom and side to side for best results These freezers come with 5 interior doors one for each shelf to help minimize the temperature transients resulting from opening the main door You should still minimize the time the freezer door is open On top of letting the cold air out you are also let...

Страница 7: ...iated with the alarm system i e delay times system status a battery backup which will maintain the alarm system for several hours after a power failure to allow for continued alarm and notification functions The temperature monitor system does NOT control the temperature of the unit That function is performed by the Microprocessor Digital Temperature Control which is preset at the factory and shou...

Страница 8: ... pressed The MUTE PROGRAM button has three functions In Normal Run mode if the unit is beeping pressing the button will mute the beeper for a preset time Each time the button is pressed the mute time resets Holding the button down for two seconds takes the unit out of Normal Run mode and into Programming mode At the same time it mutes the beeper When in Programming mode pressing the button steps t...

Страница 9: ...d the BEEPER and ALARM LED will both activate Press the MUTE PROGRAM button to stop the beeper for a specified time changing the sound to short chirps When the temperature goes back within range and there are no out of range readings for thirty seconds the chirping stops and the MUTE PROGRAM button resets If another out of range condition then occurs the beeper will again start at full volume Afte...

Страница 10: ...in a short period 5 Once the Monitor is in Programming mode each time the Mute button is pressed the display steps to the next parameter As the display steps to the next parameter the value of the previous parameter is saved Once the final parameter is reached pressing the MUTE button returns the monitor to Normal Run mode saving the final parameter Description of Parameters for Control Center Hi ...

Страница 11: ...emote Alarm Relay is a single pole double throw SPDT relay that changes state switches with the loss of line power or with the presence of an alarm condition NOTE The relay is rated for pilot duty operation only Do NOT use it for control switching The relay contacts and connections are rated at 30v 1A In normal applications the relay signals remote alarms or central monitoring systems that an alar...

Страница 12: ...e of the unit A touch keypad allows the user to easily select the display units set point differential set point and heating or cooling mode Please Note The digital temperature controller has been factory set and tested to allow your unit to operate at its desired temperature cycle Adjusting the settings on the controller will alter these factory settings WE STRONGLY RECOMMEND YOU CONTACT THE MANU...

Страница 13: ...t point and S1 will be blinking Press the up and down keys to adjust to the desired setting S1 blinking Set point Temperature Press SET key again to access the differential mode The LCD will display the current differential and DIF1 will be blinking Press the up and down keys to adjust to the desired setting DIF 1 blinking Differential Temperature Press SET key again to access the cooling or heati...

Страница 14: ...ry EP Appears when the probe is open shorted or sensing a temperature that is out of range Check to see if the sensed temperature is out of range If not check for probe damage by comparing it to a known ambient temperature between 30 F and 220 F Replace the probe if necessary EE Appears if the EPROM data has been corrupted This condition cannot be field repaired Replace the control CL Appears if c...

Страница 15: ...eplacements are pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerator s rear or side walls Evaporator is blocked by frost or ice Remove the products unplug the refrigerator or freezer power and allow the unit to defrost If the problem still exists call for service 3...

Страница 16: ...vent leakage Door will not close The unit is not level Refer to the Leveling section at the beginning of this manual Check for dirt and debris or items passing through the door seal MOISTURE DURING THE SUMMER SEASON The amount of moisture condensation or high humidity related issues increase during the summer and in most cases will self resolve when the weather cools down Please note a refrigerati...

Страница 17: ...ing soda in 1 quart of warm water Be sure to wring excess water out of sponge or cloth before cleaning around controls light bulb or any electrical parts Door Gaskets Soap and water Wipe gaskets and their seating surfaces with a clean soft cloth Shelves Soap and water Do not wash removable shelves in dishwasher Exterior and Handles Soap and water Non Abrasive Glass Cleaner Do not use commercial ho...

Страница 18: ... pan occasionally to ensure it does not overflow A inch garden hose adaptor available at most hardware stores can be used to drain the freezer directly into a floor drain Replace the drain plug when defrosting is complete so warm air does not enter the freezer through the hole Defrosting tips If the frost is soft remove it with a plastic scraper If the frost is glazed and hard fill deep pans with ...

Страница 19: ...TY In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship under normal use and service for a period of three 3 additional years from the end of the initial two 2 year warranty period but not to exceed five 5 years after shipment from Horizon Scientific Inc...

Страница 20: ...ood or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage caused by the storage of any corrosive material that comes in contact with the interior or exterior portions of the cabinet or the use of spark producing equipment or containers such as galvanized or carb...

Отзывы: