background image

- 4 -

Power Wire Terminal Block (Connector A)

● 

Power +VDC & -GND

  1. Connect to the positive (+) battery terminal. Fuse each wire independently @35 Amps (user-supplied). 

DO NOT install these fuses until the wiring for the entire system has been completed.

  2. Connect to the vehicle’s chassis ground (typically adjacent to the battery).

  3. Plug the Connector A into the siren amplifier.

Control Wire Harness (Connector B)

 

Ignition Activation (IGN) input

  Apply +VDC continuously to 

RED 

wire to enable the siren system. Connect this wire to a positive 

circuit controlled by the vehicle ignition switch to allow the siren amplifier to be turned on & off together. 

The system does not operate without this Ignition Activation. DO NOT directly connect this wire to the 

battery as this may drain battery.

● SW1 Output

    Connect to auxiliary device power up to 5 Amps max. or use as Lightbar function activation switch.

● SW2 Output

    Connect to auxiliary device power up to 5 Amps max. or use as Lightbar function activation switch.

● SW3 Output

    Connect to auxiliary device power up to 5 Amps max. or use as Lightbar function activation switch.

● SW4 Output

    Connect to auxiliary device power up to 5 Amps max. or use as Lightbar function activation switch.

● Speaker Out

  Connect the 

BLUE 

(SPK+)

 

and

 BROWN

 (SPK-) wires to one 100W 11-ohm impedance speaker.

 

Radio Re-broadcast

    Connect 

WHITE 

and 

GREY

 wire to the speaker output of a radio console.

 

Horn Ring Transfer (HRT) input

  Apply +VDC continuously to 

PINK 

wire for Air Horn tone. 

Содержание Logic 1100

Страница 1: ... C B LGS 1100 H Abrams Logic 1100 Programmable Handheld Siren System Light Controller NOTICE TO INSTALLER Before installation and operation read all instructions and warnings Deliver this manual to the end user of this product ...

Страница 2: ...in the manual from the original manufacturer 6 The operator should verify the siren system is fastened to the vehicle securely and is functioning properly Failure to follow all safety precautions and instructions may cause property damage injury or death 7 Ensure that any switch control panel is located in an area that allows both the vehicle and the control panel to be operated safely in any driv...

Страница 3: ...00 Watts Siren Output Load 100W ACR 11Ω Siren Frequency 758Hz 1587Hz 447Hz 596Hz HI LO Max Current 10A 12VDC 5A 24VDC w o light control outputs 30A 12VDC 25A 24VDC w 4x light control ouputs Standby Current w o IGN wire 4 5 mA 12V 10 mA 24V w IGN wire 0 37 A 12V 0 28 A 24V Operating Temperature Range 30 65 Light Controls 4x 5A light control outputs Fuse Ratings Built in 5A blade fuse on each of the...

Страница 4: ...OUT PINK HORN RING TRANSFER HRT INPUT GREY RADIO IN WHITE RADIO IN RADIO SPEAKER OUTPUT BLUE SPK OUT FEET American Wire Gauge METERS IEC 60228 2004 Standard Wire Cross Section 10A 20A 30A 40A 22AWG 20AWG 18AWG 16AWG 14AWG 12AWG 10AWG 6AWG 8AWG 3 5 7 5 12 19 5 31 49 124 Ins 4 6 9 5 15 5 24 5 62 Ins Ins Ins 4 6 5 10 5 16 5 41 5 Ins Ins Ins 3 5 7 5 12 5 31 Ins 78 39 26 19 5 Ins Insufficient 10A 20A 3...

Страница 5: ...e system does not operate without this Ignition Activation DO NOT directly connect this wire to the battery as this may drain battery SW1 Output Connect to auxiliary device power up to 5 Amps max or use as Lightbar function activation switch SW2 Output Connect to auxiliary device power up to 5 Amps max or use as Lightbar function activation switch SW3 Output Connect to auxiliary device power up to...

Страница 6: ...ill de activate the Radio Rebroadcast upon activation It may be interlocked by SW1 See Siren Interlock Horn Disable Setting section for more details RADIO Activate Radio Rebroadcast through the siren speaker This button will de activate the Siren Tone upon activation SW1 Activate SW1 Output It may be used for the primary warning light and interlocking SIREN SW2 SW3 and or SW4 See Siren Interlock H...

Страница 7: ...8 761 1592 761 1592 761 1592 450 598 761 1592 761 1592 761 1592 450 598 WAIL 12 C M YELP 158 C M HILO 40 C M PHASER 886 C M 761 1592 761 1592 450 598 761 1592 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 FRANCE FRANCE FRANCE FRANCE FRANCE GERMANY AUSTRIA AUSTRIA AUSTRIA AUSTRIA ITALY ITALY ITALY NETHERLANDS NETHERLANDS GENDARMERIE POLICE AMBULANCE POMPIERS UMH STADT LAND POLICE AMBULANCE FIREBRIGADE...

Страница 8: ...SW3 SW4 5 3 1 2 7 8 4 6 Green Red Siren Interlock Horn Disable Setting 1 Press and hold PTT MAN and SIREN for 5 seconds to enter Siren Interlock Horn Disable Setting SIREN will blink to indicate that you are in Siren Interlock Horn Disable Setting 2 While in Siren Interlock Horn Disable Setting press RADIO or SW1 or SW2 or SW3 or SW4 buttons to switch between different settings See Indication Char...

Страница 9: ...may be set as a ON OFF switch a Momentary switch or a Timer switch 1 Press and hold PTT MAN and Code 3 for 5 seconds to enter SW Button Type Setting 2 If any of the button type is not in its default setting ON OFF an auto clearing will be performed with a full blinking of the controller 3 Code 3 will blink to indicate that you are in SW Button Type Setting the button type of each SW1 4 button is i...

Страница 10: ...ting clip as a template mark the two holes to be drilled 3 Drill two mounting holes for sheet metal screws 4 Install the microphone clip with provided sheet metal screws 126 4mm 4 98 136 2mm 5 36 126mm 4 96 90mm 3 54 Top view INSTALLATION WARNING PINCH HAZARD Steel iron and or other ferrous objects may be attracted suddenly and forcefully to the magnets creating the risk of pinch type injuries Kee...

Отзывы: