2   SAFETY / PROPER USAGE  

Read through the following safety instructions thoroughly before using a sensor: 

 

1.  Note the sensor’s capacity before use and ensure that the capacity is not exceeded. Producing a 

load greater than the indicated safe overload value can damage the sensor. An overload can 

occur whether the sensor’s indicator is powered on or off. 

 

2.  In order to extend the life of the sensor, avoid repetitive shock and impact loading. 

 

3.  When moving the sensor to another location, never lift from the cable or strain relief. This can 

cause damage to the sensor. Always lift the sensor housing itself.  

 

4.  Always ensure that load is applied axially with respect to the sensor.  

 

5.  Ensure that the sensor is kept away from water or any other electrically conductive liquids at all 

times. 

 

6.  The sensor and indicator should be serviced by a trained technician only. AC power must be 

disconnected and the indicator must be powered off before the housing is opened. 

 

7.  Always consider the characteristics of the sample being tested before initiating a test. A risk 

assessment should be carried out beforehand to ensure that all safety measures have been 

addressed and implemented.  

 

8.  Typical materials able to be tested include many manufactured items, such as springs, electronic 

components, fasteners, caps, films, mechanical assemblies, and many others. Items that should 

not be used with the sensor include potentially flammable substances or products, items that can 

shatter in an unsafe manner, and any other components that can present an exceedingly 

hazardous situation when acted upon by a force. Always wear eye and face protection when 

testing, especially in aforementioned hazardous cases. Extra bodily protection should be worn if a 

destructive failure of a test sample is possible. 

 

9.  In aforementioned hazardous situations, it is strongly recommended that a machine guarding 

system be employed to protect the operator and others in the vicinity from shards or debris. 

 

10. Sensors have threaded holes or chucks, designed for the mounting of grips, fixtures, or 

attachments. If any such accessories are used, ensure they are mounted firmly to prevent a 

potential safety risk to the operator and others in the vicinity. If using an accessory from a supplier 

other than Mark-10, ensure that it is constructed of suitably rugged materials and components. 

Similar precautions should be taken when mounting the sensor to a test stand, work bench, or 

other piece of equipment. 

 

 

 

 

 

Содержание Plug&Test MR01-100

Страница 1: ...LP USA Tel 1 281 516 9292 888 275 5772 eFax 1 866 234 0451 Web https www abqindustrial net E mail info abqindustrial net Distributed by ABQ Industrial LP USA Tel 1 281 516 9292 888 275 5772 eFax 1 86...

Страница 2: ...pective user s guides For additional information or answers to your questions please do not hesitate to contact us Our technical support and engineering teams are eager to assist you Before use each p...

Страница 3: ...indicator being used must be identified and taken into account as follows Indicator Model Accuracy M7I M5I 0 1 of full scale M3I 0 2 of full scale The total system accuracy can be calculated by addin...

Страница 4: ...asures have been addressed and implemented 8 Typical materials able to be tested include many manufactured items such as springs electronic components fasteners caps films mechanical assemblies and ma...

Страница 5: ...e with a click Fig 3 1 Appropriate orientation of the Plug Test connector To release the connector press both buttons on either side of the indicator housing see Fig 3 2 Pull the connector completely...

Страница 6: ...the receptacle in the top front surface of the crosshead then fasten the thumb screws into the crosshead as shown below 4 3 Overview Tension and compression force may be applied to the surfaces with t...

Страница 7: ...000 x 0 5 16000 x 10 500 x 0 2 5000 x 2 5 x 0 002 1000 x 1 500 x 0 5 5000 x 5 MR01 1500 MR07 1500 1500 x 1 24000 x 20 750 x 0 5 7500 x 5 7 5 x 0 005 1500 x 2 750 x 1 7500 x 10 MR01 2000 2000 x 1 32000...

Страница 8: ...Threaded holes are supplied to permit mounting to various surfaces 5 3 Specifications Accuracy 0 5 of full scale Safe overload 150 of full scale Operating temperature 40 F 100 F 5 C 38 C Operating hum...

Страница 9: ...x 0 0005 200 x 0 2 100 x 0 1 1000 x 1 MR02 500 500 x 0 2 8000 x 5 250 x 0 1 2500 x 1 2 5 x 0 001 500 x 0 5 250 x 0 2 2500 x 2 MR02 1000 1000 x 0 5 16000 x 10 500 x 0 2 5000 x 2 5 x 0 002 1000 x 1 500...

Страница 10: ...I Indicator With Model M3I Indicator lbF ozF gF kgF N mN lbF gF kgF N MR03 025 0 25 x 0 0001 4 x 0 002 100 x 0 05 1 x 0 0005 1000 x 0 5 0 25 x 0 0002 100 x 0 1 1 x 0 001 MR03 05 0 5 x 0 0002 8 x 0 005...

Страница 11: ...ces with threaded holes Attachments may be threaded into these holes Finger tighten only These holes also allow for mounting as required 7 3 Specifications Accuracy 0 2 of full scale Safe overload 200...

Страница 12: ...1 x 0 001 10 x 0 01 MR04 5 MR04 5M 5 x 0 002 80 x 0 05 2500 x 1 2 5 x 0 001 25 x 0 01 5 x 0 005 2 5 x 0 002 25 x 0 02 MR04 10 MR04 10M 10 x 0 005 160 x 0 1 5000 x 2 5 x 0 002 50 x 0 02 10 x 0 01 5 x 0...

Страница 13: ...aded hole Attachments may be threaded into these holes Finger tighten only 8 3 Specifications Accuracy 0 15 of full scale Safe overload 150 of full scale Operating temperature 40 F 100 F 5 C 38 C Oper...

Страница 14: ...t the terminal lead in the slot on the upper grip Begin to compress and release the handles slowly Tension force values will be displayed on the indicator After the test is complete remove any debris...

Страница 15: ...in place with one hand use an Allen wrench with the other hand to tighten the screw that joins the crosshead to the force sensor as shown at left Optionally cover the screw head with the included blac...

Страница 16: ...0 002 50 x 0 02 FS05 20 20 x 0 01 320 x 0 2 10000 x 5 10 x 0 005 100 x 0 05 FS05 50 50 x 0 02 800 x 0 5 25000 x 10 25 x 0 01 250 x 0 1 FS05 100 100 x 0 05 1600 x 1 50000 x 20 50 x 0 02 500 x 0 2 FS05...

Страница 17: ...cell block with the pins in the underside of the crosshead Pass the included screw through the crosshead and FS06 housing and thread into the sensor 11 3 Specifications Accuracy 0 15 of full scale in...

Страница 18: ...x 0 5 25000 x 10 25 x 0 01 250 x 0 1 FS06 100 100 x 0 05 1600 x 1 50000 x 20 50 x 0 02 500 x 0 2 FS06 200 200 x 0 1 3200 x 2 100 x 0 05 1000 x 0 5 1 x 0 0005 FS06 300 300 x 0 2 4800 x 5 150 x 0 1 150...

Страница 19: ...ale Safe overload MR50 10Z MR50 50Z 300 of full scale MR50 12 MR50 100 150 of full scale Chuck opening range MR50 10Z MR50 50Z 0 062 0 375 in 1 6 9 5 mm MR50 12 MR50 100 0 078 0 5 in 2 0 12 7 mm Opera...

Страница 20: ...0 02 14 x 0 01 14 x 0 01 MR50 50Z 50 x 0 02 3600 x 2 36 x 0 02 350 x 0 2 35 x 0 02 50 x 0 05 36 x 0 05 35 x 0 05 MR50 12 12 x 0 005 1 x 0 0005 140 x 0 1 135 x 0 1 1 35 x 0 001 12 x 0 01 140 x 0 1 135...

Страница 21: ...ons Accuracy 0 2 of full scale Safe overload MR50 10Z MR50 50Z 300 of full scale MR50 12 MR50 100 150 of full scale Chuck opening range MR50 10Z MR50 50Z 0 062 0 375 in 1 6 9 5 mm MR50 12 MR50 100 0 0...

Страница 22: ...0 005 MR51 20Z 20 x 0 01 1400 x 1 14 x 0 01 140 x 0 1 14 x 0 01 20 x 0 02 14 x 0 01 14 x 0 01 MR51 50Z 50 x 0 02 3600 x 2 36 x 0 02 350 x 0 2 35 x 0 02 50 x 0 05 36 x 0 05 35 x 0 05 MR51 12 12 x 0 005...

Страница 23: ...5 kg 14 4 Dimensions in mm 14 5 Capacity x Resolution Model No With Model M7I M5I indicator With Model M3I indicator ozFin lbFin lbFft gFcm kgFmm Nmm Ncm Nm ozFin lbFin kgFmm Ncm MR52 10Z 10 x 0 005...

Страница 24: ...53 100 150 of full scale Operating temperature 40 F 100 F 5 C 38 C Operating humidity 96 max non condensing Weight MR53 10Z MR53 50Z 2 2 lb 1 0 kg MR53 12 MR53 100 5 4 lb 2 5 kg 15 4 Dimensions in mm...

Страница 25: ...0 x 0 5 570 x 0 5 MR55 100 100 x 0 1 8 x 0 01 1150 x 1 1150 x 1 11 5 x 0 01 100 x 0 1 1150 x 1 1150 x 1 MR55 200 200 x 0 2 16 x 0 02 2300 x 2 2200 x 2 22 x 0 02 200 x 0 2 2300 x 2 2200 x 2 MR55 400 40...