20
Packing, Transport and Storage
The product will be prepared for transport to its first
destination by ABNOX. The packing unit may not be
subjected to any excess load. The packaging and
its content must be protected from moisture. The
transport temperature must be kept between – 20°C
and + 40°C.
Transport Damages
If transport damages are discovered during the
inspection of incoming goods, this procedure must
be followed:
• Inform delivering party (freight carrier, etc.)
• Make record of damages
• Inform supplier
Storage
Storage and temporary storage in aggressive or
humid environments or outdoors can lead to
corrosion and other damages. The storage
temperature must be kept from – 20 °C to +40°C.
Training of Personnel
Only trained and instructed personnel who have read
and understood all points of the Operating Manual
may work on the product. Likewise the individual
operating states must be mastered, and the related
safe aspects must be known and they must be able
to implement them. Personnel undergoing training
may only work on the product under the supervision
of qualified personnel.
EN
Fault Localisation, Troubleshooting
CAUTION
Remediation of any of the faults
described below may only be
carried out by a trained technician.
Fault
Possible cause
Resolution
Lubricant pump does not start
Not connected to compressed air
supply
Connect to compressed air supply
No pressure in the compressed air
network
Increase pressure to 2-10 bar
Defective switching mechanism
Must be repaired by a specialist
Lubricant pump runs but does
not convey lubricant
No lubricant in the area of the
suction valve
Pre-fill suction valve with grease
Ensure that there is lubricant in the
area of the suction valve
Pump start with excessively high
air pressure
Start pumping with low air pressure
and gradually increase to desired air
pressure
Seal on suction valve damaged
Replace seals
Pump generates little to no
medium pressure
Air pockets
System entlüften
Leakage
Inspect fittings and hoses for
damage, repair if needed
Содержание AXSP-S
Страница 2: ...2 A B C 1 13 12 10 11 4 6 8 9 2 3 5 7 14 7...
Страница 4: ...4...
Страница 6: ...6...
Страница 87: ...87...