Abnova Precipitor 32 Скачать руководство пользователя страница 1

Affinity Magnetic Precipitation System

USER MANUAL

Precipitor   32

®

Содержание Precipitor 32

Страница 1: ...Affinity Magnetic Precipitation System USER MANUAL Precipitor 32...

Страница 2: ...of Precipitor Chapter 2 Introduction of LCD Chapter 3 The picture of wiring at the back of controller Chapter 4 I O Chart Chapter 5 Troubleshooting guide Chapter 6 Specification Chapter 7 Program imp...

Страница 3: ...Documents User manual Quality control checklist Accessories USB to serial converter driver disc USB to RS 232 transmission line RS 232 to USB connection line Magnetic base Consumables 4X 96 deep well...

Страница 4: ...lectric wire directly 6 Do not place electric wires on any subject with high temperature 7 Do not look steadily at the ultraviolet lamp while it is on 8 Disconnect the plug from the power source when...

Страница 5: ...olution well you can get clean nucleic acids after cells lysis nucleic acids absorption wash and elution Operation interface is simple There are five parts in operation interface Select Program Screen...

Страница 6: ...Panel Switches and Electrical Inlet voltage 100 240V fuse 5A 250V A Heating switch B Main power switch C USB port D Electrical inlet Internal view A Magnetic rod frame B Strip rack frame C 96 deep we...

Страница 7: ...on again to confirm to stop the program Then the robot will be back to the initiated site Press the button to turn buzzer beater off It stops temporarily when you press the button Press the button aga...

Страница 8: ...mbers is to press the buttons or and change the digits from 0 to 9 Finally press the button to confirm the number you select The years are started from A D Insert the last two digits For example inser...

Страница 9: ...digits is to press the button or Select the digits from 0 to 9 Then press the button to confirm it TEMP Press the button or to select the TEMP then press the button to enter the Perform Temp Screen P...

Страница 10: ...e digits from RT to 70 then press the button to confirm it 3 Heater ON OFF Press the button to turn on or the button to turn off heater V Perform UV Lamp Screen Set working time of UV Lamp hh mm Start...

Страница 11: ...temperature It shows NA when there is no preset input STATUS It shows the machine being what kind of status END The program is finished RUNNING The program is progressing PAUSE To make a short stop H...

Страница 12: ...working time of strip minute COLLECT The working time of magnetic rod second VAPOR The time for waiting reaction or alcohol vaporization mm ss START Start time of program hh mm ss END End time of pro...

Страница 13: ...efer to the picture as below Press the button to run the selection program and then go to Press the button to return to 2 After entering press the button to execute the program Confirm two things belo...

Страница 14: ...e stopped and finished The robot will go back to the initial site 1 Press the button in the process of executing program the execution will be stopped immediately The robot will stop working immediate...

Страница 15: ...r It means variable electric resistance Green 2PIN outlet J14 connecting to thermocouple 9PIN outlet is the usage of transmitting program P2 26PIN outlet connecting to UV lamp heater and cooler tune t...

Страница 16: ...bottom of plate rack Contact service center 886 2 87511888 Please make sure the two screws are removed before turning on the power Press the button Stop to terminate the program Then press the button...

Страница 17: ...om 15 Specification Product Name Preciptor 32 Width cm 38 Height cm 31 Length cm 31 Weight Kg 19 Power V 100 240 Current A max 2 Operating temperature RT 65 Humidity Range 80 Processing Volume l 100 1...

Страница 18: ...he original password is 0 You could rebuild another set of new password but no more than 6 Arabic numerals 3 1 RS 232 transmission line can be connected to the RS232 port of PC 3 2 For portable comput...

Страница 19: ...www abnova com 17 AutoMag software key in your user name and password 6 digits at the most change your password confirm your password Protocol Edit window...

Страница 20: ...the file Cut Copy Paste Move up Move down Insert Delete Choose a COM port There 16 COM ports COM1 is a preset port Reset a new COM port The program can record it so that you won t have to set it agai...

Страница 21: ...in row you could cut off a whole row of data However if you highlight a certain cell all you could cut is the data in the field length that you mark 3 5 Copy Select a certain row click to copy a whole...

Страница 22: ...u could set 100 programs at most it could be from 00 99 Use serial numbers as the names of files when you store files 15 characters at the most Only letters of the alphabet and Arabic numerals You cou...

Страница 23: ...on seconds 999 seconds is the maximum It takes 30 seconds to move the magnetic rod reaching the lowest position Therefore do not set collect time less than 30 seconds Used magnetic rod or not Drop dow...

Страница 24: ...r will ringing at the same time Please press the button to stop buzz Press the button to continue the program The time to waiting reaction or alcohol vaporization After finishing this step it will sto...

Страница 25: ...to a machine please save the program first and then key in the number of the program that you are going to transmit After that click If it is transmitted normally a word will appear in the lower left...

Страница 26: ...Abnova Corporation 9F No 108 Jhouzih St Neihu Taipei 114 Taiwan Tel 886 2 8751 1888 Fax 886 2 6602 1218 Rev March 2012...

Отзывы: