![Abloy DA400 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/abloy/da400/da400_manual_3434416006.webp)
ADJUSTMENT OF THE DOOR MOVEMENTS
Control unit adjustments and selections
Control unit:
When the mains supply is connected, the control unit immediately adopts the status
determined by the program selector and the opening pulses. Only the green OK
LEDis lit.
Press one of the. three buttons and the display will show the status of the door
operator.
'
Display functions and program push
buttons:
The display
comprises of two digital
displays, three LED's and three push
buttons.
The left display section shows the status
of the
program selector.
When a
programme button is pressed, the digital
display lights up, indicating the status of
the program selector e.g. 0
=
MANUAL,
1= AUTOor 2=OPEN.
The right-hand display section indicates
the status of opening pulses, the safety
sensor and the locking circuit.
Program selector
I'
pulse display
status
I
ro~~~~
C)
Ixking
circuit
impulse OutSIde
impulse inside
signoJ dot
;rnpulse oU1side
int"~bi1
Se
S/A-
Adj
OK
o
o
~
,--,
,
,
'-I
;
'--'.
Signal LED's
a)
The green OK LED
is lit when the mains supply
is connected to the door operator. The
normal operating status.
b)
The yellow LED
is not normally lit. The adjustment
LED is on when control point 0 ... 28 has been
selected using the selection
+
button.
Error
c)
The red Error LED
when lit indicates an error
condition has occurred.
El
=
safety sensor fault; check the sensor connections
E3
=
button error; check the sequencing (jumpers
and connections)
ES
=
battery
fault; check the battery
E8
=
Eprom error; replace the control unit
9