Ablerex MSRT-Pro 1.5KVA Скачать руководство пользователя страница 27

 

52 

(AC Mode )    

105

 continuous 

106

%~

120

  for 30 seconds transfer to bypass   

121

%~

150

  for 10 seconds transfer to bypass 

150

        for immediately transfer to bypass 

Buzzer continuously alarms. 

(Battery Mode)   

105

 continuous 

106

%~

120

  for 30 seconds shuts down 

121

%~

150

  for 10 seconds shuts down 

150

        for immediately shuts down  

Buzzer continuously alarms. 

Overload 

(Bypass Mode)   

105

 continuous 

106

%~

120

  for 250 seconds shuts down   

121

%~

130

  for 125 seconds shuts down 

131

%~

135

  for 50 seconds shuts down 

136

%~

145

  for 20 seconds shuts down 

146

%~

148

  for 5 seconds shuts down 

149

%~

157

  for 2 seconds shuts down 

158

%~

176

  for 1 seconds shuts down 

177

%~

187

  for 0.32 seconds shuts down 

188

        for 0.16 seconds shuts down 

Buzzer continuously alarms.

 

Short Circuit   

Bypass mode : Input Fuse/Input Breaker 
Normal Mode: Output Breaker/Electronic Circuit 
Battery Mode: Output Breaker/Electronic Circuit 

Battery ABDM 

EPO 

UPS shuts down immediately 

Normal Mode   

Transfer to Bypass Mode 

Over 
Temperature 

Battery Mode 

UPS shuts down immediately 

Audible Alarm 

Battery Mode 

Sounding once every 1.5 seconds 

Low Battery 

  Sounding once every 0.2 seconds 

Overload 

Sounding once every 3 second 

Fault Continuously 

Sounding

or Sounding once every 3 second

 

 

53

 

Physical 

Dimensions(HxWxD in mm) 

88(2U)x440x

405 

88(2U)x440x

405 

88(2U)x440x 650 

88(2U)x440x 

650 

115V 34.5Ib(15.7kg)

34.5Ib(15.7kg)

61.3lb(27.9kg) 68.6Ib(31.2kg) 

Weights 

230V 34.2Ib(15.1kg)

(not available)

62.0lb(28.2kg) 65.5Ib(29.8kg) 

115V

NEMA 5-15P

NEMA 5-15P

NEMA 5-20P 

NEMA L5-30P 

Input Connection 

230V

10A, IEC 320-

C14 

(not available)

10A, IEC   

320-C14 

16A, IEC   

320-C20 

115V

5-15R×6 5-15R×6 

5-15R×2 

5-20R×2 

5-15R×4 

L5-30R×1

 

Output Connection 

230V

(6) 10A,IEC 

320-C13 

(not available)

(6) 10A,IEC 320-

C13 

(4) 10A,IEC 

320-C13 

(1) 16A,IEC 

320-C19 

Environmental 

Operation Temperature 

0-40

 

Noise Level 

50dBA 

Relative Humidity   

0 to 90% (Without condensation) 

Interface 

Interface Type 

1 *USB port+ 1*RS-232 port 

SNMP(option) 

Power management from SNMP manager and Web browser 

Compatible platforms 

Windows 95/98/NT/2000/XP Novell NetWare, Linux, etc. 

Standards and Certification 

Safety 

IEC/EN 62040-1-1,IEC 60950-1 

Performance IEC/EN 

62040-3 

EMC  

IEC/EN62040-2 Class A, FCC Part 15 Subpart B Class A, 

IEC/EN55011, CISPR11, IEC61000-4-2/-3/-4/-5, IEC61000-2-2, 

IEC61000-3-2/-3 

Markings 

CE,UL, cUL, FCC 

 
 

Содержание MSRT-Pro 1.5KVA

Страница 1: ...n 17 4 1 Unpacking 17 4 2 Selecting Installation Position 18 4 3 Set up 19 4 4 Operation 23 5 UPS Working Principle 36 5 1 UPS System Block Diagram 36 5 2 When Utility is Normal 37 5 3 When Utility is...

Страница 2: ...all ventilation openings free from obstruction and do not place anything on top of the UPS Keep the UPS rear panel 20 cm away from the wall or other obstructions 8 The battery will discharge naturally...

Страница 3: ...ion even in the most difficult of environment with space constraints 2 This UPS is equipped with fully digitalized control logic for greater functionality and enhanced high level of power protection D...

Страница 4: ...o indicate there is an output available at the Programmable Outlet 1 Programmable Outlet 2 Amber LED lights up to indicate the Bypass Input is normal UPS Fault LED UPS On Alarm Silence UPS OFF Switch...

Страница 5: ...n Service Mode 7 OFF UPS Shutoff 8 FAIL UPS Abnormal Lock 9 UPS Flow Chart 10 4 Digits Measurement Display 11 Indicate the item desired to be measured 12 Er05 Battery Weak or Dead 13 Er06 Output Short...

Страница 6: ...put circuit breaker for two programmable outlets 230V 1 1 5KVA 2KVA 3KVA 11 3 3 Operating Modes Voltage System Configurations Download and open the UPS Setting Tool Software to see the screen as below...

Страница 7: ...y existing after setting is complete 3 seconds later reconnect input power cord into AC Power Utility receptacle and turn on the UPS referring to the section 4 4 Operation The UPS will perform in new...

Страница 8: ...e to shutdown whole unit without internal power supply existing after setting is complete 3 seconds later reconnect input power cord into AC Power Utility receptacle and turn on the UPS referring to t...

Страница 9: ...ation Read the Safety Instruction guide page 2 to 3 before installing the UPS 4 1 Unpacking Inspect the UPS upon receipt The manufacturer designed robust packaging for your product However accidents a...

Страница 10: ...arance from the rear panel of the UPS to avoid any obstructions 2 Do not block the air flow to the ventilation louvers of the unit 3 Please ensure the installation site is free from excessive dust and...

Страница 11: ...20 Power Module Battery Module Step 1 Step 2 A4 S1 21 Rack Mount Configuration Setup Step 1 Step 2 Step 3...

Страница 12: ...er source when the UPS had been switched on The LED on the front panel display will light off while the LED will be illuminated and the buzzer alarm will beep intermediately indicating the UPS is in B...

Страница 13: ...inated when the self test is completed without finding any faults or abnormal conditions The LED will automatically lights off 30 sec after the successful self test 4 4 2 LCD panel Optional 4 4 2 1 St...

Страница 14: ...he LCD display illustrates from drawing G to drawing H then the UPS will be in self test Mode The UPS may offer energy to the output in a minute and the LCD display illustrates as drawing I In case of...

Страница 15: ...ng P1 P1 P2 2 Press key pad to scroll down the LCD screen then check the UPS settings The LCD display will show in sequence Drawing P1 buzzer Drawing Q1 self test Drawing R1 Bypass Voltage Drawing S O...

Страница 16: ...Q2 all the rest default settings may be changed by pressing scroll up key pad 4 Drawing R1 and R2 mean the bypass input acceptable window it can be 180Vac 260Vac for 220Vac system 90Vac 130Vac for 11...

Страница 17: ...zer will sound twice d Turn off the Breaker of the Utility Input e The UPS lock problem is solved now 33 4 4 2 7 Shut Off 1 Press key pad for about 5 seconds the Inverter output will be turned off the...

Страница 18: ...34 4 4 4 Battery Replacement Step 1 Step 2 35 Step 3 Step 4 1 1 5KVA 2K 3KVA...

Страница 19: ...d Utility Abnormal under or over voltage Absent Rectifier and charger stop operating Battery discharge via DC DC boost circuit and supply to Inverter Loads continue to receive supply from Inverter Ala...

Страница 20: ...after a preset threshold to avoid the battery from over drain The Battery Low LEDs will light up till the UPS is completely cut off The UPS will re start automatically when Utility is available Fig 5...

Страница 21: ...temperature If the UPS experiences internal over temperature when Utility is normal it will switch to bypass loop The UPS will switch back to inverter mode when the over temperature situation is elimi...

Страница 22: ...e has been wrongly wired or if the Ground Neutral Voltage exceeded the limits 5 Verify if the ventilating fans are functioning properly Do not attempt to replace the fans by yourself Contact your loca...

Страница 23: ...tery Disconnect Er28 Bypass overload Er31 EEPROM s data not conform to the Jumper Setting 45 6 3 Maintenance Clean the dust from the ventilation openings and intakes on the rear panel 1 Turn off the U...

Страница 24: ...2 cable is provided with the UPS USB cable is optional 7 2 Software Installation Please refer to the user s manual of the bundled software CD_ROM for installation guide EPO G DC 36V AC OUTPUT 2 1 47 8...

Страница 25: ...al Slot 8 3 5 Flexible signal output for N C Normal Close or N O Normal Open contact by shorting pin1 2 or pin2 3 form JP1 5 8 3 6 The shutdown function will be enabled in 1 minute after blackout occu...

Страница 26: ...Regulation 1 until low battery warning Output INV mode Frequency Synchroniz ed Range 3Hz or 1Hz setting by software 51 Frequency Battery Mode 0 1 0 05 0 06Hz unless synchronized to line PF 0 7 3 1 Cu...

Страница 27: ...nce every 1 5 seconds Low Battery Sounding once every 0 2 seconds Overload Sounding once every 3 second Fault Continuously Sounding or Sounding once every 3 second 53 Physical Dimensions HxWxD in mm 8...

Страница 28: ...54 55 192321132048001...

Отзывы: