ABLE Computrac Vapor Pro Rx Скачать руководство пользователя страница 3

 

Page 3  

Table of Contents 

 

1.

 

WARNINGS AND SAFETY INFORMATION .............................................................................................. 4

 

2.

 

INTRODUCTION .............................................................................................................................................. 6

 

3.

 

PRINCIPLES OF OPERATION ...................................................................................................................... 7

 

4.

 

UNPACKING ..................................................................................................................................................... 8

 

5.

 

INSTALLATION ............................................................................................................................................... 9

 

6.

 

CHECK SENSOR STATUS ............................................................................................................................. 13

 

7.

 

DRYNESS TEST ................................................................................................................................................ 14

 

8.

 

RH SENSOR CALIBRATION CHECK ......................................................................................................... 15

 

9.

 

RH SENSOR CALIBRATION ......................................................................................................................... 17

 

10.

 

TEMPERATURE CALIBRATION ................................................................................................................. 19

 

11.

 

RUNNING MOISTURE TESTS ...................................................................................................................... 21

 

Selecting Test Settings .................................................................................................................. 21

 

Entering Material Name ............................................................................................................... 21

 

Selecting Programmed Test Temperature .................................................................................. 22

 

Selecting Units for the Final Result Display ............................................................................... 22

 

Selecting How to End the Test ..................................................................................................... 22

 

Selecting Sample Weight Entry Method ..................................................................................... 23

 

Selecting Bottle Purge Control ..................................................................................................... 24

 

12.

 

DETERMINING OPTIMUM PARAMETERS .............................................................................................. 25

 

13.

 

RUNNING MOISTURE TESTS USING UNSEALED BOTTLES ............................................................... 27

 

RUNNING LYOPHILIZED MOISTURE TESTS .................................................................... 27

 

14.

 

COMPUTRAC

®

 

VAPOR PRO

®

 RX

 MENU SYSTEM ................................................................................. 29

 

Memory Start Menu ..................................................................................................................... 31

 

Stored Data Menu   (Not available on 21 CFR, Part 11 compliant instruments) .................... 31

 

Calibration Menu .......................................................................................................................... 32

 

Setup Menu .................................................................................................................................... 33

 

Diagnostic Menu ............................................................................................................................ 35

 

15.

 

CONDITION PROMPTS AND SYSTEM FAILURE CODES ..................................................................... 36

 

Condition Prompts ........................................................................................................................ 36

 

System Failure Codes .................................................................................................................... 37

 

16.

 

COMMONLY ASKED QUESTIONS .............................................................................................................. 38

 

17.

 

REPAIR AND MAINTENANCE ..................................................................................................................... 42

 

ACCESS COVER REMOVAL .................................................................................................... 42

 

INSTRUMENT COVER REMOVAL ........................................................................................ 43

 

TO INSPECT THE FILTER AND TUBING: ............................................................................ 43

 

Q: “How do I change the filter?”  Not on all instruments. ........................................................ 44

 

Q:  “How do I Adjust the Dry Air Flow?” .................................................................................. 45

 

18.

 

SPECIFICATIONS AND RATINGS ............................................................................................................... 47

 

19.

 

WARRANTY ..................................................................................................................................................... 48

 

 

 

An updated electronic copy of this manual is available at 

www.azic.com

Содержание Computrac Vapor Pro Rx

Страница 1: ...ley Reading Berkshire RG6 4UT UK Tel 44 0 118 9311188 Email info able co uk Aberdeen Office Unit 6 Airside Business Park Kirkhill Industrial Estate Dyce Aberdeen AB21 0GT UK Tel 44 0 1224 725999 Email...

Страница 2: ...in connection with any information storage or retrieval system without the express written permission of Arizona Instrument LLC ALL RIGHTS RESERVED Copyright 2002 2013 Arizona Instrument LLC PLEASE N...

Страница 3: ...ING OPTIMUM PARAMETERS 25 13 RUNNING MOISTURE TESTS USING UNSEALED BOTTLES 27 RUNNING LYOPHILIZED MOISTURE TESTS 27 14 COMPUTRAC VAPOR PRO RX MENU SYSTEM 29 Memory Start Menu 31 Stored Data Menu Not a...

Страница 4: ...rd from the instrument to ensure complete power removal Position the power cable so that it cannot touch any hot areas of the moisture analyzer Use only AZI supplied accessories and options with VP Se...

Страница 5: ...ecome contaminated follow the directions contained in this manual beginning on page 42 Every precaution has been taken to prevent contaminants from entering the unit However if liquids or powders do e...

Страница 6: ...termination of the sample s moisture content The heating range of the Computrac VAPOR PRO Rx is 25 C to 275 C Test parameters such as sample size heater temperature and test ending criteria can be alt...

Страница 7: ...detect water in the gas stream is a polymer capacitor relative humidity sensor The reading from this sensor is combined with sensor block temperature and carrier gas flow data in a microprocessor to...

Страница 8: ...or Kit Y990 0116 1 Vapor Pro Hydrophobic Filter Kit Y990 0155 Optional Accessories Hydrophobic Filter 990 0059 101 key PC keyboard 990 0088 Travel case 990 0092 Digital balance with cable and Communic...

Страница 9: ...re required by the instrument and therefore no additional regulator is need This is the ideal choice for portable operation Examples of regulators capable of regulating pressure to 30 psi follow For c...

Страница 10: ...17 and 22 psi 118 152 kPa Compressed Gas Cylinder The facilities air or gas supply is usually connected to a wall or bench mounted regulator The regulator is connected to the desiccator with clear tub...

Страница 11: ...ated next to the fuse holder is in the off O position Remove the fuse holder from the power entry module by prying with a small flat screwdriver Change the fuse A unit operating from 100 120 VAC shoul...

Страница 12: ...Page 12 After a quick view of the instrument identification and the firmware version the Main Test Screen will appear Allow the instrument to warm up for 20 minutes...

Страница 13: ...t requirements of each menu screen From the Main Test Screen press Menu to reveal the Main Menu Move the cursor down to highlight the Diagnostic Menu Press Selct Verify that the View System Sensor Sta...

Страница 14: ...EST Press START This test will run for two 2 minutes to test for moisture that may have migrated into the system If this is the first test after changing a portion of the flow system tubing needle fil...

Страница 15: ...15 seconds If the tube is not full the reading will be low Pull the capillary tube straight up out of the water A rapid but straight motion will tend to remove excess water from the side of the tube E...

Страница 16: ...struments Highlight ANALYZE STORED DATA and press Selct Highlight and Selct the desired results to be included in the statistics and Press Stat to calculate Average Standard Deviation and Coefficient...

Страница 17: ...th the water long enough to fill If the tube is not full the reading will be low Pull the capillary tube straight up out of the water A rapid but straight motion will tend to remove excess water from...

Страница 18: ...via email at support azic com When five tests results are available press Menu and the Main Menu Screen appears Select CALIBRATION MENU Select PERFORM RH SENSOR CAL Press Selct Down and Selct to sele...

Страница 19: ...onal Install the Temperature Calibration Probe into the calibration port to the rear of and below the bottle ramp as shown The probe must be inserted all the way in until the handle touches the case R...

Страница 20: ...instructions assume that the verification is being run automatically AUTO VERIFY ON If you do not wish to edit the temperatures press Esc and move to the next step To select which temperature s will b...

Страница 21: ...setting a blank line and Press Selct Entering Material Name Press Selct then Edit at the Edit Sample ID line Use the Left and Right keys to move the cursor s position left and right Use the Incr and...

Страница 22: ...be changed Use the Incr and Decr keys to scroll through the numbers When complete press Quit followed by Accpt When toggled on the COLD START ENABLE function allows testing to begin at an ambient temp...

Страница 23: ...he programmed microgram per second value after the programmed time period has elapsed This ending criterion is useful for samples that take a long time to heat up before evolving moisture or in other...

Страница 24: ...l adjust the purge time to that number of seconds Average materials may use 30 to 45 seconds to purge the bottle Samples that evolve moisture readily may need less than 30 seconds or no purge time at...

Страница 25: ...results find out what sample size and sensitivity setting was used in the KF procedure Use approximately 1 5 to 2 times as much sample in the Computrac VAPOR PRO Rx and set the rate ending criteria v...

Страница 26: ...r variation of results For your particular application call AZI Customer Service at 800 528 7411 or 602 470 1414 for assistance in developing specific parameters After determining the optimum test par...

Страница 27: ...ero and the test will begin For some applications this bottle purge time may need to be reduced If the expected results are not obtained after other parameters are adjusted call AZI Customer Service a...

Страница 28: ...der with the lever Keep track of the bottles in the order of testing After all tests are complete open and clean out the sample bottles Weigh the bottle cap and septa Weigh everything but the freeze d...

Страница 29: ...t s collected moisture and rate information Use the soft key buttons below the display to make your selection Main Test Screen The Graph key will switch the display to the graphical displays When you...

Страница 30: ...ions MEMORY START MENU STORED DATA MENU CALIBRATION MENU SETUP MENU DIAGNOSTIC MENU Use the Up and Down keys to scroll through the selections Use the Esc and Selct keys to Escape or Select your choice...

Страница 31: ...nter or computer Printing must be enabled and programmed Go to the SETUP MENU EXT PRINTER SETUP and REPORT SETUP MENUS to select the port and report content Stored Data Menu Not available on 21 CFR Pa...

Страница 32: ...Sensor V0 and V75 found on the sensor PCB and entered when a sensor is replaced The calculated offset value entered by the instrument during a RH Sensor Calibration This value should only be changed b...

Страница 33: ...Report Start off start of a test end of a test Report Format text or spreadsheet Report Interval 00 to 99 seconds Automatic Form Feed End of line form feed ON or OFF Include Graph none result rate bo...

Страница 34: ...enable access protection MASTER KEY controls all functions CALIBR KEY controls calibration access TDLTO Allows entry of an AZI supplied password that will override a factory lockout feature This locko...

Страница 35: ...s Manual Off returns the system to automatic control of the flow state High Flow high flow through the needle and RH sensor for system drydown Low Flow normal flow through the needle and RH sensor Bot...

Страница 36: ...of carrier gas not connected Connect source Source pressure too low Increase source pressure to 20 psi Flow system filter plugged Remove and replace filter Source connected to flow out barb Connect t...

Страница 37: ...ATER 10 RH RTD TRACK ERROR Sensor Block RTD OUT OF POSITION 11 BOTTLE RTD RANGE ERROR CABLE OR RTD FAIL 12 BOTTLE RTD RATE ERROR BOTTLE HEATER FAILURE 13 BOTTLE HEATER OVERTEMP BOTTLE HTR RTD OUT OF P...

Страница 38: ...le the sensor block and if a filter is used on the instrument inspect the filter also to be sure that no contaminants are present that might absorb and release large quantities of water If contaminati...

Страница 39: ...UAL FLOW CONTROL MENU and switch the MANUAL FLOW CONTROL to BOTTLE PURGE After 5 10 seconds solvent should begin to be expelled from the outlet port at the back of the instrument When solvent expulsio...

Страница 40: ...ment to print to the RS 232 port Setup Menu External Printer Setup Go to Setup Menu Report Setup Report Control and select text output Set up the computer to receive text information into its serial p...

Страница 41: ...ttle Weight if all bottles are pre weighed by hand Weigh Empty Bottle if the balance is to tare weigh each bottle before it is filled with sample Escape Esc to the Ext Balance Setup Menu Connect the c...

Страница 42: ...nstrument s cover To prevent electrical shock turn off power and remove the power cord Do not re connect the power cord and turn power on until after the cover is secured in place ACCESS COVER REMOVAL...

Страница 43: ...over See ACCESS COVER REMOVAL on page 42 NOTE Not all instruments use a Hydrophobic Filter but if it is used it is visible at right center above the Sensor Block Examine the filter and tubing If a dep...

Страница 44: ...change the filter Not on all instruments A First obtain a replacement Hydrophobic Filter AZI Part Number 990 0059 One filter was contained in the accessory kit If it has been used call AZI Customer S...

Страница 45: ...use Q How do I Adjust the Dry Air Flow CAUTION Line voltage is present under the instrument s cover Use care not to touch any components except those listed in the following procedure to prevent elect...

Страница 46: ...rd from its socket Replace the Instrument cover access cover and power cord Turn the instrument on The instrument is ready for normal use On newer instruments Locate the flow regulator that is mounted...

Страница 47: ...y 0 5 to 1 5 Overall Length from 29 5 mm to 65 mm approximately 1 16 to 2 5 Power Ratings 100 120 V 50 60 Hz 8 amps maximum or 220 240 V 50 60 Hz 4 amps maximum Environmental Requirements 5 to 40 C 0...

Страница 48: ...air or replacement of the defective part or parts as provided above Under no circumstances shall AZI be liable in any way to the owner or any user for any damage including but not limited to any loss...

Страница 49: ...indows is a registered trademark of Microsoft Corporation in the United States and other countries Arizona Instrument LLC Computrac VAPOR PRO Rx Moisture Analyzer User Manual Part Number 700 0050 Revi...

Отзывы: