![ABLE BEKA BA504E Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/able/beka-ba504e/beka-ba504e_installation-and-maintenance-instructions-manual_3412598020.webp)
18
8.3.1 Solid state output
Each alarm has a galvanically isolated single pole
solid state switch output which as shown in Fig 10.
The output is polarised and current will only flow in
one direction.
Ron
=
less than 5
Ω
+ 0.7V
Roff
=
greater than 1M
Ω
Fig 10 Equivalent circuit of each alarm output
The solid state output of each alarm may be used
to switch any dc circuit with parameters equal to or
less than:
V
=
40V
I
=
200mA
Fig 11 Typical alarm application
(Shown without recommended screened cables)