110406_ABI-EV1012_QSG_ML.doc
English
Page
5
N.V.
abitana
S.A.
ENGLISH
ABI-EV1012S00
Twisted Pair Broadband
Distribution Amplifier with 2 RF
inputs and IR-bus
Quick Start Guide
1
Package Contents
•
DIN rail mountable Broadband Amplifier module
•
Quick Start Guide
•
3
Termination
plugs
•
Power jumper cord ABI-PS1001SPC
2 Tools
•
Level
tester
ABI-TT1003S12
•
Spanner
11mm
•
Flat screw driver max. 5mm x 0.6mm
3 Introduction
The ABI-EV1012S00 is a Broadband Amplifier with two coaxial
inputs (one for CATV signal or antenna, and the other for the
connection of a Broadband modulator)
The unit has 4 independent RJ45 (Twisted Pair) outputs on the
front.
A range of Twisted Pair to Coax adapters (with or without
adjustment, filters, IR…) is available for installation at the receiver
end (i.e. ABI-AC1001S00*).
It is possible to connect a Radio by using a Radio adapter (ABI-
AC1004S00) or an adaptor without a filter.
4 Connectors
P1
P2
P3
POWER
P4
RF IN 1
Input to CATV signa l
or Antenna
Outputs to 4 indepent
TV Sets
RF IN 1 Power Adjustment
RF IN 2
Input to
RF modula tor output
IR-bus
IR-bus
Grounding wire
Power level a djustment
Connection for
IR Detector
ABI-AC1007S00
5 Power
Load ratio for this module = 0,5.
Maximum allowed load ratio (sum of the load ratios for all modules) for
power supply ABI-PS1001S11 = 4.
6 Installation
Power Off the central
ABI-PS1001S11
Power Supply by means of the
Circuit Breaker installed in the ‘
Comm Center Cabinet
’, or by
removing the mains power cord from the Power Supply.
1.
Make sure the shielding of the Network Interface Unit (NIU)
or CATV transition point is properly connected to the
protective ground.
2.
Open the ‘Comm Center Cabinet’
3. Click the ABI-EV1012S00 unit on the metal DIN-rail,
adjacent to the ABI-EV1017S00 modulator (left or right side)
for IR-bus functionality.
4. The ABI-EV1012S00 is supplied with a grounding wire,
connected to the input F-connector.
This wire (1) must be connected to the protective ground of
the installation.
The following system devices also need to be connected to
the protective ground: The DIN-Rail frame (2) and the Power
supply (3)
EV1002
Power
Supply
DIN-Rail Frame
PE1002
1
2
3
4
DC1015
ABI-PS1001SPC
5. Provide power to the module using the included power
jumper cord ABI-PS1001SPC. Please consult the manual of
the power supply for more information concerning the
installation of the power supply.
6.
Connect a coax cable from the CATV connection point (NIU)
or the CATV transition point to the coax connector on the top
of the unit.
7.
Connect a coax cable (F-F patch cord) from the RF output of
the ABI-EV1017S00 modulator to the coax connector (RF IN
2) on top of the ABI-EV1012S00.
Tighten the screws of the connector, using the spanner
.
Failing to follow the instructions (1) to (7) in the specified order
may lead to permanent damage of the ABI-EV1012 amplifier
When it is impossible to connect the DIN rails ,frame or CATV
transition point to ground, make sure they are at least at the same
electrical level (connected to each other).
Please also note our recommendation regarding overvoltage at
the end of this manual