Abilia Emfit Epilepsy Alarm Скачать руководство пользователя страница 8

3.  Introduction 

  These instructions for use describe the use of the Emfit MM, Tonic-Clonic Seizure 

Monitor. The version number and details can be found in chapter 

23. Technical 

specifications

  Use the device only in the ambient conditions specified by the manufacturer. For 

detailed information, refer to 

Technical Specifications 

in these instructions for use. 

  Follow all instructions provided in this document concerning the installation, use and 

cleaning of the device. 

  Based on the intended use, point 1) of section 3.2 below, the Emfit Tonic-Clonic 

Seizure Monitor is a medical device as defined in the Medical Device Directive 
93/42/EEC. Based on the nature of point 2) regarding the intended use, the device is 
not defined as a medical device (Directive 93/42/EEC, Article 1(2), subparagraph a). 

  The device is a Class I medical device in accordance with the Medical Device 

Directive 93/42/EEC and carries the CE marking accordingly. 

 

3.1  Product description 

Emfit Tonic-

Clonic Seizure Monitor (later “product”) is a movement monitor that is used to 

detect and notify tonic-clonic seizures. 

The product consists of a bed sensor located under the mattress and a control unit where 
the bed sensor is connected. Control unit should be placed on a table, clipped on bed or 
mounted on wall. 

The control unit notifies caregiver by flashing led and sound (unless muted) and/or 
transfers a notification via external system e.g. a nurse call system or a personal 
emergency phone. 

Operating environment is typically bedroom at care-home or home. 

 

3.2  Intended use 

The product is intended to be used to assist in sensory monitoring and to notify the 
caregiver 

1) of the body movements of a person lying on a mattress equipped with the under-
mattress sensor due to a tonic-clonic seizure while sleeping. 

2) of the presence of the monitored person on the mattress equipped with the under-
mattress bed sensor and if he or she gets up from the mattress. 

The device may either be used 

  solely for the task described in point 1) above, 

  for the tasks described in points 1) and 2) above simultaneously. 

 

NOTE 1

 

The manufacturer cannot guarantee that the device will detect all episodes of tonic-clonic 
seizure-induced body movements of the monitored person.  

NOTE 2

 

The device may trigger a false body movement notification, especially if the person lying 
on the mattress fitted with the under-mattress bed sensor is awake.  

Содержание Emfit Epilepsy Alarm

Страница 1: ...onitor Art no 464000 464031 Note The device must not be used if an operational failure of the device might lead to a delay in getting the appropriate treatment or medication for the patient which coul...

Страница 2: ...2...

Страница 3: ...6 3 SW 1 switch function switch 6 12 6 4 Adjusting the notification sound volume switches 7 and 8 12 7 Inserting batteries and battery service life 13 8 5V AC External power supply optional 14 9 Conne...

Страница 4: ...al of the device after use 23 21 Declaration of conformity EU 23 22 Abilia limited warranty statement 23 22 1 Your guarantee 23 22 2 Terms 23 22 3 Exclusions and limitations 24 22 4 Your legal rights...

Страница 5: ...nications or local area networks If this device is used with a pressure care mattress filled using a compression pump the device may not function normally in some cases Equipment is not suitable for u...

Страница 6: ...se chapter Electromagnetic conditions Symbol of European Waste Electrical and Electronic Equipment Directive WEEE Directive 2002 96 EC on waste electrical and electronic equipment in these instruction...

Страница 7: ...certified in the external power supply Product is C TICK certified in the external power supply Product is China RoHS 30 certified in the external power supply Product is BSMI certified in the externa...

Страница 8: ...consists of a bed sensor located under the mattress and a control unit where the bed sensor is connected Control unit should be placed on a table clipped on bed or mounted on wall The control unit no...

Страница 9: ...operator is the caregiver of the user The operator needs to be adult who fully understands instructions and limitations of use mentioned in these instructions for use Otherwise no special skills or k...

Страница 10: ...details picture 2 In the event of a power failure two high quality 1 5V AA alkaline batteries can be used as an emergency power supply Do not use any rechargeable batteries or lithiumion batteries Re...

Страница 11: ...er supply and remove nurse call cable if used from connector X2 before opening the lid Remove the batteries and disconnect the power supply before setting up the DIP switches in order to implement the...

Страница 12: ...switched on or off by pressing the switch for three 3 seconds OFF down The SW1 switch does not act as the On Off switch The device is always on when it is connected to the power supply or when the bat...

Страница 13: ...is someone in bed 75 of that time there are two notifications per day and sound notification is on 30 seconds each time When the batteries are getting low the red LED will begin to flash slowly A beep...

Страница 14: ...s connected the batteries act as backup power supply in the event of a power failure All alkaline batteries self discharge and start to leak when empty contaminating the device Ensure that batteries a...

Страница 15: ...the bed sensor picture 13 the power supply delivered as an accessory picture 14 and any connector cables picture 15 according to the pictures 9 1 X2 AUX Connector Pin Order picture 16 From left to rig...

Страница 16: ...place the bed sensor under the mattress or mattress topper never just under the sheet The bed sensor must not come into direct contact with a person The bed sensor is designed to last for a minimum o...

Страница 17: ...press the switch for too long you might accidentally switch off the device The notification sound will also stop when the fast paced movements stop 12 3Bed exit alarm bypass switch The SW1 switch act...

Страница 18: ...f No one is on the bed 13 2Blue Device on standby Light is off Device is switched off Light flashes slowly Device is switched on Light flashes rapidly a few times Device triggers a notification 13 3Re...

Страница 19: ...re high priority signals that will overrule information signals if both signals activate simultaneously 14 1Alarm signals Two high and low BEEPS in a loop Fast movements alarm goes off Three high and...

Страница 20: ...bed should not last long enough for the notification to sound Person weight Switch position in parenthesis if false alarms occur 75 kg 1 0 50 75 kg 2 1 35 50 kg 3 2 or 1 25 35 kg 4 or 5 3 or 2 15 25 k...

Страница 21: ...of the bed sensor under the mattress The correct position is at the chest height of the user and across the bed 3 Power supply battery check if power supply is used Make sure that power supply and bed...

Страница 22: ...e device on only after the person has fallen asleep If the bed exit alarm is enabled DIP switch 3 in DOWN position and sensitivity is not set high enough alarm may trigger Either disable alarm DIP swi...

Страница 23: ...ntact your dealer distributor or manufacturer To avoid any unnecessary inconvenience on your part we recommend you read these instructions for use carefully before seeking guarantee service 22 1Your g...

Страница 24: ...beyond specifications or features described in the instructions for use or modifications to the product to conform it to national or local technical or safety standards in countries other than those...

Страница 25: ...xample some countries prohibit the exclusion or limitation of damages resulting from negligence gross negligence wilful misconduct deceit and similar acts Abilia s liability under this guarantee will...

Страница 26: ...eset switch 8 pcs DIP switches for settings volume delay one 10 position rotary switch for adjusting sensitivity Signal lights 3 LEDs green blue and red Delays Movement notification delay alternatives...

Страница 27: ...W 15 W Output voltage 5 VDC Output current 1 2 A 3 0 A Electrical safety class Class II 23 4Ambient conditions Operating temperature 10 40 C Storage and transport temperature 30 50 C Relative humidity...

Страница 28: ...pecified below The customer or the user of the equipment should assure that it is used in such an environment RF emissions CISPR 11 Group 1 The Emfit Tonic Clonic Seizure Monitor uses RF energy only f...

Страница 29: ...61000 4 5 1 kV line s to line s IEC 60601 1 2 test level Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on...

Страница 30: ...each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may...

Страница 31: ...to frequency of transmitter 150 kHz 80 MHz d 1 2 P 80 MHz 800 MHz d 1 2 P 800 MHz 2 5 GHz d 1 2 P 0 01 0 12 m 0 12 m 0 23 m 0 1 0 38 m 0 38 m 0 73 m 1 1 2 m 1 2 m 2 3 m 10 3 8 m 3 8 m 7 3 m 100 12 m...

Страница 32: ...32 26 Appendix Related pictures...

Страница 33: ...33...

Страница 34: ...34...

Страница 35: ...35...

Страница 36: ...36 464000 464031_Manual Emfit Tonic Clonic Seizure Monitor_EN_RevF1 docx Dec 2017...

Отзывы: