49
4.3 Setting the channel range
Your Control Medi has the option to set different channel ranges for the transmitter to
operate within. When the change of channel range is applied, programmed channels will
disappear and a new random code is added on the
Code
-button
!
.
Normally, the channel range does not need to be changed. If several GewaLink transmitters
are to be used in the same area and you do NOT want to control the same equipment, it
may be necessary to use different channel ranges.
Table 3 shows the different settings.
Table 3: Channel ranges
Channel ranges, GewaLink channels
00-23
1
16-39
2
32-55
3
56-79
4
80-103
5
104-127
6
Level 1
00-05
16-21
32-37
56-61
80-85
104-109
Level 2
06-11
22-27
38-43
62
1
-67
86-91
110-115
Level 3
12-17
28-33
44-49
68-73
92-97
116-121
Level 4
18-23
34-39
50-55
74-79
98-103
122-127
1
Channel 62 is a stop code and cannot control any function. On the other hand you can store channels/codes
on this button which in turn can control a function.
Do as follows to set the channel range:
1. First press
and then simultaneously press
2
for 2 seconds. When you release the
buttons the
“Setting” alert sounds and the indication lamp on button 2 flashes.
2. Press
4
.
3. Choose the channel range
1
to
6
according to table 3 above.
4. If the action is successful, the
“Success” alert sounds. If something goes wrong or takes
too long, the “Error” alert sounds.
Setting the channel range
Press
---
+
2
2 sec
,
4
,
choose the channel range
.
1
=
00-23,
2
= 16-39,
3
= 32-55,
4
= 56-79,
5
= 80-103,
6
= 104-127
Default setting: GewaLink channel 16-39
---