xFUME™ ADVANCED HP 230V – CSA
5 Transport and installation
EN
-
11
4.3 Technical data
5 Transport and installation
Fig. 2 Assembly and use on page EN
► Install the device and lock the castors
.
Tab. 1
General information
xFUME™ ADVANCED HP 230V – CSA
Connection voltage
230 V
Rated frequency
60 Hz, 3.6 kW
Rated current
16 A
Drive power
2 × 1.8 kW
Filter surface
2 × 0.63 m²
Connection diameter
58.8 mm
Max. air volume flow
1
1 One extraction hose connection length 5 m connected, second connection closed.
420 m³/h
Sound pressure level LpA
< 75 dB (A)
Max. inlet air pressure
6 bar
Weight
56 kg
Dimensions (L × W × H)
513 mm × 370 mm × 990 mm
Tab. 2
Ambient conditions for transport, storage and operation
xFUME™ ADVANCED HP 230V – CSA
Ambient temperature (operation, storage in
a closed environment)
0 °C to +40 °C
Ambient temperature (transport)
-15 °C to +40 °C
Relative humidity
Up to 90 % at +20 °C
WARNING
Risk of injury due to improper transport and installation
Improper transport and installation can cause the device to tip or fall over. This may result in serious
injuries.
► Check and wear your personal protective equipment.
► Ensure that the extraction hose is laid in a straight line.
► Ensure that all supply lines and cables do not encroach into the area in which employees are working.
► Place the device on a suitable base (flat, solid, dry) on which it will not topple over.
► Note the weight of the device when lifting it.
► Use an appropriate lifting tool with load handling attachment for transporting and installing the
device.
► Avoid abrupt lifting and setting down.
► Do not lift the device over persons or other devices.
NOTICE
Risk of material damage due to improper transport and installation
Improper transport or installation can cause the device to tip or fall over. This can result in material
damage and irreparable damage to the device.
► Protect the device against weather conditions, such as rain and direct sunlight.
► Ensure that the device does not make contact if you pass over edging.
► Use the device only in dry, clean and well-ventilated rooms.
► Maintain a minimum distance of 1 m from the wall when installing the device to ensure that the device
has sufficient ventilation.