4 Putting into operation
MAG
1
Lay down the cable assembly
straight.
2
, tip adaptor
and gas
.
3
Unscrew nut
from central connector
.
4
Slide liner
through the wire conduit
up to the retaining nipple
5
Screw in nut
6
Cut off the excess length of the liner
pull out the liner
.
7
Sharpen the spiral guide liner beginning to an angle of approx. 40° and
debur the cutting point.
8
Slide sharpened liner
up to the retaining
.
9
Screw in nut
10
Screw in gas diffuser
, tip adaptor
, and contact tip
and attach
4.3 Mounting the cable assembly
1
Combine central connector and central socket at the wire feed unit and
secure them with the connecting nut.
2
Properly mount the connections for water supply/return, shielding gas and
control line plug.
1
Gas diffuser
2
Torch neck
3
Wire conduit
4
Retaining nipple
5
Nut
6
Central connector
7
Liner
8
Cable assembly
9
Contact tip
10
Gas nozzle
11
Tip adaptor
Fig. 2
Liner
40°
1
2
10
11
3
4
8
5
6
7
9