14
FreedomDrive
4.7
Connecting the FreedomDrive control lead
Fig. 10
Connecting the FreedomDrive Control Lead
Note: Connection varies by machine.
Connecting the FreedomDrive Control Lead:
1. Power source must be “off” and power cord disconnected from incoming
power.
2. Connect the FreedomDrive MIG gun to the wire feeder.
3. Connect the control lead to the wire feeder or the Universal control box,
depending on gun type.
4. Reconnect the power cord, turn on the machine and gas supply prior to
welding.
4.8
Setting the Shielding Gas:
Note
• The type and quantity of the shielding gas depends on the welding task
and the gas nozzle geometry.
• Make all shielding gas connections leak free.
• To prevent the shielding gas supply from becoming clogged by impuri-
ties, the cylinder valve must be opened briefly before connecting the
cylinder. This will blow out any impurities that may be present
FreedomDrive
Back End
Control Lead
Содержание FreedomDrive Abimig AT355
Страница 23: ...23 FreedomDrive Notes...