![Abicor Binzel BRS-LCi Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/abicor-binzel/brs-lci/brs-lci_operating-instructions-manual_451475030.webp)
EN - 12
6 Putting into operation
BRS-LCi
5
Check the clearance between the proximity switch
and the transmitter disc
and correct it if
necessary.
6
Loosen the screws
7
Move the proximity switch
axially and tighten the screws
.
8
Check the freewheeling of the transmitter disc
by turning the motor.
6.8 Adjusting the injection unit quantity
For adjusting the spray quantity, the system must be provided with compressed air. In order to assess the
function and the spray quantity, the solenoid valve Y3 must be switched.
Fig. 13 Connecting the pneumatic system on page EN-16
1
Connect siphon hose
to the release agent cylinder if necessary.
2
Switch on Y4.
3
Adjust the quantity of release agent by means of the adjusting screw
4
Switch off Y4.
1
Cleaning unit
2
Injection and air blast unit
3
Extraction hose (release agent)
4
Adjusting screw
5
Extraction hose (release agent)
6
Supply line (compressed-air
motor)
Fig. 9
Adjusting the injection unit fluid quantity
1
4
2
3
5
6
WARNING
Danger of crushing
Limbs can be drawn in and crushed by moving parts (milling cutter, clamping unit).
• Do not reach between moving parts.
WARNING
Damage to the eyes
Sprayed release agent may damage the eyes.
• Wear safety goggles.
• Only adjust release agent by switching the solenoid valve Y3.
Содержание BRS-LCi
Страница 19: ...BRS LCi 12 Entsorgung DE 19 ...
Страница 38: ...EN 20 12 Disposal BRS LCi ...
Страница 56: ...BRS LCi 12 Elimination FR 19 ...
Страница 74: ...BRS LCi Notizen Notes Notes Notas ES 19 Notizen Notes Notes Notas ...
Страница 75: ...ES 20 Notizen Notes Notes Notas BRS LCi ...