EN - 10
6 Putting into operation
MAG
6.3 Mounting the machine side cable assembly
1
and central socket
at the wire feed unit
and secure them with the connecting nut
.
6.4 Connecting the cooling system
1
Cable assembly
2
Connection nut
3
Central connector
4
Wire basket spool
5
Shielding gas cylinder
6
Power supply
7
Wire feed unit
8
Central socket
Fig. 3
Mounting the cable assembly on the machine side
1
2
3
4
5
6
7
8
NOTE
• Check once again whether the wire guide liner has been fastened
correctly.
WARNING
Risk of burns
MAG will become overheated if the coolant level is too low.
• Wear protective gloves.
• Check the coolant level at regular intervals.
NOTE
• Applies only to liquid-cooled MAG welding torches.
• Make sure that the coolant supply and return have been installed
properly. Coolant supply = blue, Coolant return = red.
• Make sure that liquid-cooled MAG welding torches are only operated
with the
ABICOR BINZEL
coolant BTC-15.
Содержание AUTC 61GD