EN - 18
10 Troubleshooting
ABIPLAS
®
WELD 250 MT
2
Clean lines by blowing compressed air through them from behind.
10 Troubleshooting
WARNING
Risk of injury
Serious injuries caused by parts swirling around.
• When cleaning with compressed air, wear suitable protective clothing, in
particular safety goggles.
CAUTION
Material damage
The welding torch is destroyed on the inside by impurities.
• Never blow compressed air into the nozzles from the front.
NOTE
• If the measures described below are not successful, please consult your
dealer or the manufacturer.
• Please also consult the operating instructions for the welding
components, such as the power source, welding torch system, re-
circulating cooling unit, etc.
Fault
Cause
Solution
Pilot arc is not ignited
• Tungsten electrode and plasma
nozzle make contact
• Distance between tungsten
electrode and plasma nozzle
too large
• Tungsten electrode is worn out
or oxidized
• Re-adjust electrode
• Re-adjust electrode
• Re-sharpen and adjust
electrode
Main arc is not ignited
• Distance between work-piece
and torch too large
• Pilot arc is not burning
• Shorten distance
• Ignite pilot arc
Tab. 15